Delivers a guaranteed accuracy range that starts at 1 mΩ. The frequency band has been expanded to 8 MHz, broadening the array of measurement targets with which it can be used.
Delivers a guaranteed accuracy range that starts at 1 mΩ. The frequency band has been expanded to 8 MHz, broadening the array of measurement targets with which it can be used.
Delivers repeatability that is an order of magnitude better than that of previous products. This level of performance makes the instrument ideal for use in applications such as electrolytic capacitor low-ESR measurement and power supply coil impedance testing, the latter of which demands excellent frequency characteristics.
Features
This product is not supplied with the measuremnt probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately.
Applications
Measurement Modes | LCR mode, Continuous measurement mode |
Measurement Parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε |
Measurement Range | 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z) |
Display Range | Z: 0.00 m to 9.99999 GΩ, Rs, Rp, Rdc X: ±(0.00 m to 9.99999 GΩ) G, B: ±(0.000 n to 9.99999 GS) Ls, Lp: ±(0.00000 µ to 9.99999 GH) Cs, Cp: ±(0.0000 p to 9.99999 GF) Y: 0.000 n to 9.99999 GS θ: ±(0.000° to 999.999°) Q: ±(0.00 to 9999.99) D: ±(0.00000 to 9.99999) Δ %: ±(0.000 % to 999.999%) |
Basic Accuracy | Z: ±0.05% rdg. θ: ±0.03° (representative value, measurable range: 1 mΩ to 200 MΩ) |
Measurement Frequency | 4 Hz to 8 MHz (10 mHz to 100 Hz steps) |
Measurement Signal Level | [Normal mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA) 1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA) [Low impedance high accuracy mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA) [Normal mode: CC mode] 4 Hz to 1.0000 MHz: 10 µA to 50 mA (maximum 5 V) 1.0001 MHz to 8 MHz: 10 µA to 10 mA (maximum 1 V) [Low impedance high accuracy mode: CC mode] 4 Hz to 1.0000 MHz: 10 µA to 100 mA (maximum 1 V) [DC resistance measurement] Measurement Signal level: Fixed at 1 V |
DC Bias Measurement | Generating range: DC voltage 0 V to 2.50V (10mV resolution) In low Z high accuracy mode: 0 V to 1V (10mV resolution) |
Output Impedance | Normal mode: 100 Ω Low impedance high accuracy mode: 10Ω |
Display | 5.7-inch color TFT with touch panel |
Functions | Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function |
Interfaces | EXT. I/O( HANDLER), USB, USB flash drive, LAN, GP-IB, RS-232C, BCD |
Power Supply | 100 to 240V AC, 50/60 Hz, 50 VA max. |
Dimensions and Mass | 330 mm (12.99") × 119 mm (4.69") × 230 mm (9.06") 4.2 kg (148.1 oz) |
Click on a category to view a selection of compatible accessories with the Hioki IM3536 DC LCR Meter, 4Hz to 8MHz.
Measurement Modes | LCR mode, Continuous measurement mode |
Measurement Parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε |
Measurement Range | 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z) |
Display Range | Z: 0.00 m to 9.99999 GΩ, Rs, Rp, Rdc X: ±(0.00 m to 9.99999 GΩ) G, B: ±(0.000 n to 9.99999 GS) Ls, Lp: ±(0.00000 µ to 9.99999 GH) Cs, Cp: ±(0.0000 p to 9.99999 GF) Y: 0.000 n to 9.99999 GS θ: ±(0.000° to 999.999°) Q: ±(0.00 to 9999.99) D: ±(0.00000 to 9.99999) Δ %: ±(0.000 % to 999.999%) |
Basic Accuracy | Z: ±0.05% rdg. θ: ±0.03° (representative value, measurable range: 1 mΩ to 200 MΩ) |
Measurement Frequency | 4 Hz to 8 MHz (10 mHz to 100 Hz steps) |
Measurement Signal Level | [Normal mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA) 1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA) [Low impedance high accuracy mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA) [Normal mode: CC mode] 4 Hz to 1.0000 MHz: 10 µA to 50 mA (maximum 5 V) 1.0001 MHz to 8 MHz: 10 µA to 10 mA (maximum 1 V) [Low impedance high accuracy mode: CC mode] 4 Hz to 1.0000 MHz: 10 µA to 100 mA (maximum 1 V) [DC resistance measurement] Measurement Signal level: Fixed at 1 V |
DC Bias Measurement | Generating range: DC voltage 0 V to 2.50V (10mV resolution) In low Z high accuracy mode: 0 V to 1V (10mV resolution) |
Output Impedance | Normal mode: 100 Ω Low impedance high accuracy mode: 10Ω |
Display | 5.7-inch color TFT with touch panel |
Functions | Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function |
Interfaces | EXT. I/O( HANDLER), USB, USB flash drive, LAN, GP-IB, RS-232C, BCD |
Power Supply | 100 to 240V AC, 50/60 Hz, 50 VA max. |
Dimensions and Mass | 330 mm (12.99") × 119 mm (4.69") × 230 mm (9.06") 4.2 kg (148.1 oz) |
Click on a category to view a selection of compatible accessories with the Hioki IM3536 DC LCR Meter, 4Hz to 8MHz.