Measure and store up to 15,900 temperature readings with this vaccine kit, capable of taking measurements from -40 to 210°F (-40 to 99°C) with an external probe. In addition, This kit comes equipped with a temperature recorder, an external probe, a buffer bottle, a wall mount bracket, and a calibration certificate.
Measure and store up to 15,900 temperature readings with this vaccine kit, capable of taking measurements from -40 to 210°F (-40 to 99°C) with an external probe. In addition, This kit comes equipped with a temperature recorder, an external probe, a buffer bottle, a wall mount bracket, and a calibration certificate.
See if temperature excursions have occurred at a glance with this vaccine kit, designed to show the current day and up to the previous 29 days. Additionally, this kit features a built-in alarm if temperature readings are outside pre-set limits.
Features
Applications
External Temperature Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 14 to 104°F (-10 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for measurements -40 to 122°F (-40 to 50°C) 0.4°F (0.2°C) for measurements 122 to 158°F (50 to 70°C) 0.5°F (0.3°C) for measurements 158 to 176°F (70 to 80°C) 0.7 to 1°F (0.4 to 0.6°C) for measurements 176 to 210°F (80 to 99°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Recording Capacity | 15,905 temperature readings. 66 days at 6 minute logging Day summary statistics memory (for display on LCD): up for 30 days of maximum/minimum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to hourly |
Download Time | Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used. |
Environmental | IP61 (when vertically mounted or hung) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard External Probe Cable Lengths | Standard: 4’11" (1.5 m ) Extended: 9’10" (3 m) (recommended maximum). |
Remote External Probe Type | PTFE (FDA food contact rated) coaxial |
Case Material | Polycarbonate |
Power | Source: 3 V CR2032 (LiMnO2) coin cell battery, user replaceable Life: 1 year storage, followed by 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer↵than 30 seconds each time, download data monthly) NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
Dimensions | 0.33 x 2.14 x 3.66" (8.6 x 54.5 x 93 mm) |
Weight | 0.09 lbs (41g) without external probe |
Click on a category to view a selection of compatible accessories with the LogTag TRED30-16R Vaccine Kit with external probe, -40 to 210°F.
External Temperature Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 14 to 104°F (-10 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for measurements -40 to 122°F (-40 to 50°C) 0.4°F (0.2°C) for measurements 122 to 158°F (50 to 70°C) 0.5°F (0.3°C) for measurements 158 to 176°F (70 to 80°C) 0.7 to 1°F (0.4 to 0.6°C) for measurements 176 to 210°F (80 to 99°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Recording Capacity | 15,905 temperature readings. 66 days at 6 minute logging Day summary statistics memory (for display on LCD): up for 30 days of maximum/minimum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to hourly |
Download Time | Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used. |
Environmental | IP61 (when vertically mounted or hung) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard External Probe Cable Lengths | Standard: 4’11" (1.5 m ) Extended: 9’10" (3 m) (recommended maximum). |
Remote External Probe Type | PTFE (FDA food contact rated) coaxial |
Case Material | Polycarbonate |
Power | Source: 3 V CR2032 (LiMnO2) coin cell battery, user replaceable Life: 1 year storage, followed by 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer↵than 30 seconds each time, download data monthly) NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
Dimensions | 0.33 x 2.14 x 3.66" (8.6 x 54.5 x 93 mm) |
Weight | 0.09 lbs (41g) without external probe |
Click on a category to view a selection of compatible accessories with the LogTag TRED30-16R Vaccine Kit with external probe, -40 to 210°F.