Hioki CM4141-90 True RMS AC Clamp Meter with wireless adapter, 2000 A AC

Model: CM4141-90

Hioki CM4141-90 True RMS AC Clamp Meter with wireless adapter, 2000 A AC

Model: CM4141-90

Engineered for high-current industrial applications, this clamp meter provides True RMS measurements up to 2000 A AC and features a slim, durable jaw for easy access in tight electrical panels. Bundled with the Z3210 Wireless Adapter, it enables seamless Bluetooth® data transfer, optimizing field diagnostics and reporting.

Engineered for high-current industrial applications, this clamp meter provides True RMS measurements up to 2000 A AC and features a slim, durable jaw for easy access in tight electrical panels. Bundled with the Z3210 Wireless Adapter, it enables seamless Bluetooth® data transfer, optimizing field diagnostics and reporting.

Your Price $351.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki CM4141-90 Offers

Easy! Just connect the Z3210 Wireless Adapter to your Hioki compatible instrument, to make it Bluetooth® ready.

Wirelessly connect Hioki-compliant instruments with a simple connection.

Transfer measurements to your smartphone or tablet and quickly create reports with field photos and drawings.

Features

  • CAT IV 600 V, CAT III 1000 V. When using P2010: CAT III 2000 V, CAT IV 1000 V
  • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm
  • Measure up to 2000 A AC
  • AC A, AC and DC V, DC+AC V, resistance, frequency, and more
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
  • Harmonic analysis from 1st to 30th order with GENNECT Cross
  • Accuracy guaranteed for one year

DC High V Probe Mode

  • Enables high voltage measurement up to CAT III 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2010 to compatible Hioki clamp meters

Wireless support

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

Excel® Direct Input Function

Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.

Harmonic measurement

When combined with GENNECT Cross (*), you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

*GENNECT Cross is an free app that lets you connect field measuring instruments to smartphones and tablets using Bluetooth® communications. Wireless Adapter Z3210 (sold separately) is required in order to pair the instrument with GENNECT Cross.

Clamp Sensor gets between wires even with Large Jaw Diameter

Despite the ability to measure up to 2000 A AC afforded by the large sensor with φ55mm core diameter, the clamp meter’s innovative jaw design lets you get between the narrow spaces between crowded cables with absolute ease. In addition, electrical panels are sometimes so crowded that you need to push and pull to the clamp to get it around the cable. The CM4141-50 features a robust construction that delivers strength while letting you weave through complex wiring to get to the right cable, vastly improving work efficiency and speed.

Compared with clamp meters of similar class, the meter weighs only 300 g, at least 100 g lighter than competitors, letting you use the instrument over long work days with significantly less effort and physical strain.

Applications

  • High-current AC measurement
  • Wireless data monitoring
  • Industrial power diagnostics

Hioki CM4141-90 Specifications

AC Current Range 60.00 to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS)
Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range)
Crest factor For the 60.00 A range: 2.5 (greater than 50.00 A and less than or equal to 60.00 A) to 2000 A range: 1.5 (2000 A or less)
DC Voltage Range 600.0 mV to 1000 V (when using P2010: 600.0 to 2000 V)
AC Voltage Range 6.000 to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS)
Basic accuracy 45-66 Hz: ±0.9% rdg. 0.003 V (at 6 V)
DC+AC Voltage Range 6.000 to 1000 V, 4 ranges
Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance Range 600.0 Ω to 6.000 MΩ, 5 ranges
Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic Capacity Range 1.000 to 1000 μF, 4 ranges
Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency Range Voltage: 9.999 to 999.9 Hz 3 ranges
Current: 99.99 Hz to 999.9 Hz 2 ranges
Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz)
Temperature (K) -40 to 752°F (-40.0 to 400.0˚C)
Basic accuracy: ±0.5% rdg. ±5.4°F (±3.0˚C) + temperature probe accuracy
Harmonic Levels [With Z3210 installed] Harmonic levels up to 30th, content factor, total harmonic distortion ratio
Displayed via GENNECT Cross app
Other Functions Continuity check, Diode check, Automatic AC/ DC detection (Voltage check only), Max/ Min/ AVG/ Peak waveform MAX/ Peak waveform MIN value display, Low-pass filter function, Display value hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment, and other function
Dustproof, Waterproof IP20 (current measurement of voltage or hazardous live conductors under completely dry condition. Do not use when wet.)
IP50 (when measuring resistance, or current of an insulated conductor (completely dry), and in storage)
Power Supply LR03 Alkaline battery ×2
Continuous use: approximately 48 hours (without Z3210 installed), approx. 24 hours (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value
Core Jaw Diameter φ2.17" (55 mm)
Jaw dimension: 3.23 x 0.43" (82 x 11 mm), dimension is a range value of 1.73" (44 mm) from the tip of the jaw
Smallest Dimension of Jaw Cross-Section 0.43" (11 mm), range value of 1.73" (44 mm) from the tip of the jaw
Dimensions 2.56 x 9.72 x 1.38" (65 x 247 x 35 mm)
Weight 10.6 oz (300 g)

What's included with the Hioki CM4141-90

  • Clamp Meter
  • Wireless Adapter Z3210
  • Test Lead L9300
  • Carrying Case C0203
  • 2 x LR03 Alkaline Battery
  • 2 x Instruction Manual
  • Operating Precautions

Hioki CM4141-90 Offers

Easy! Just connect the Z3210 Wireless Adapter to your Hioki compatible instrument, to make it Bluetooth® ready.

Wirelessly connect Hioki-compliant instruments with a simple connection.

Transfer measurements to your smartphone or tablet and quickly create reports with field photos and drawings.

Features

  • CAT IV 600 V, CAT III 1000 V. When using P2010: CAT III 2000 V, CAT IV 1000 V
  • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm
  • Measure up to 2000 A AC
  • AC A, AC and DC V, DC+AC V, resistance, frequency, and more
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file
  • Harmonic analysis from 1st to 30th order with GENNECT Cross
  • Accuracy guaranteed for one year

DC High V Probe Mode

  • Enables high voltage measurement up to CAT III 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2010 to compatible Hioki clamp meters

Wireless support

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

Excel® Direct Input Function

Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.

Harmonic measurement

When combined with GENNECT Cross (*), you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

*GENNECT Cross is an free app that lets you connect field measuring instruments to smartphones and tablets using Bluetooth® communications. Wireless Adapter Z3210 (sold separately) is required in order to pair the instrument with GENNECT Cross.

Clamp Sensor gets between wires even with Large Jaw Diameter

Despite the ability to measure up to 2000 A AC afforded by the large sensor with φ55mm core diameter, the clamp meter’s innovative jaw design lets you get between the narrow spaces between crowded cables with absolute ease. In addition, electrical panels are sometimes so crowded that you need to push and pull to the clamp to get it around the cable. The CM4141-50 features a robust construction that delivers strength while letting you weave through complex wiring to get to the right cable, vastly improving work efficiency and speed.

Compared with clamp meters of similar class, the meter weighs only 300 g, at least 100 g lighter than competitors, letting you use the instrument over long work days with significantly less effort and physical strain.

Applications

  • High-current AC measurement
  • Wireless data monitoring
  • Industrial power diagnostics

Hioki CM4141-90 Specifications

AC Current Range 60.00 to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS)
Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range)
Crest factor For the 60.00 A range: 2.5 (greater than 50.00 A and less than or equal to 60.00 A) to 2000 A range: 1.5 (2000 A or less)
DC Voltage Range 600.0 mV to 1000 V (when using P2010: 600.0 to 2000 V)
AC Voltage Range 6.000 to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS)
Basic accuracy 45-66 Hz: ±0.9% rdg. 0.003 V (at 6 V)
DC+AC Voltage Range 6.000 to 1000 V, 4 ranges
Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance Range 600.0 Ω to 6.000 MΩ, 5 ranges
Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic Capacity Range 1.000 to 1000 μF, 4 ranges
Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency Range Voltage: 9.999 to 999.9 Hz 3 ranges
Current: 99.99 Hz to 999.9 Hz 2 ranges
Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz)
Temperature (K) -40 to 752°F (-40.0 to 400.0˚C)
Basic accuracy: ±0.5% rdg. ±5.4°F (±3.0˚C) + temperature probe accuracy
Harmonic Levels [With Z3210 installed] Harmonic levels up to 30th, content factor, total harmonic distortion ratio
Displayed via GENNECT Cross app
Other Functions Continuity check, Diode check, Automatic AC/ DC detection (Voltage check only), Max/ Min/ AVG/ Peak waveform MAX/ Peak waveform MIN value display, Low-pass filter function, Display value hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment, and other function
Dustproof, Waterproof IP20 (current measurement of voltage or hazardous live conductors under completely dry condition. Do not use when wet.)
IP50 (when measuring resistance, or current of an insulated conductor (completely dry), and in storage)
Power Supply LR03 Alkaline battery ×2
Continuous use: approximately 48 hours (without Z3210 installed), approx. 24 hours (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value
Core Jaw Diameter φ2.17" (55 mm)
Jaw dimension: 3.23 x 0.43" (82 x 11 mm), dimension is a range value of 1.73" (44 mm) from the tip of the jaw
Smallest Dimension of Jaw Cross-Section 0.43" (11 mm), range value of 1.73" (44 mm) from the tip of the jaw
Dimensions 2.56 x 9.72 x 1.38" (65 x 247 x 35 mm)
Weight 10.6 oz (300 g)

What's included with the Hioki CM4141-90

  • Clamp Meter
  • Wireless Adapter Z3210
  • Test Lead L9300
  • Carrying Case C0203
  • 2 x LR03 Alkaline Battery
  • 2 x Instruction Manual
  • Operating Precautions

More Hioki Products