Compact and standalone, this improved data logger measures voltage, temperature, humidity, pulse, and logic signals using 10 input channels and faster update speed. Moreover, this logger features alarm history, calculations, a memory loop with 8 GB of data storage, and two software for easy operation and display.
Compact and standalone, this improved data logger measures voltage, temperature, humidity, pulse, and logic signals using 10 input channels and faster update speed. Moreover, this logger features alarm history, calculations, a memory loop with 8 GB of data storage, and two software for easy operation and display.
Simple, portable, and versatile, this newly evolved datalogger introduces new features such as cloud access, alarm history function, enhanced CH to Ch calculation, memory loop function, and G-remote services. Acting as the replacement for the GL240, the GL260 showcases improved visibility, improved operability, improved functionality, new calculations, memory loop functions, software, and a new battery pack!
Features
Applications
Analog Input | Number of channels: 10 channels/screw terminal (M3) Type: Scans channels for sampling, all channels isolated, balanced input Measurement range: Voltage: 20 mV to 100 V, 1 to 5 V F.S. Thermocouple: K, J, E, T, R, S, B, N, C (and the old W: WRe5-26) Humidity: 0 to 100%, optional item B-530 (sold separately) is required Filter: Off, 2, 5, 10, 20 (moving average in selected number) Maximum input voltage between ± terminal: 20 mV to 1 V range: 60 V p-p 2 to 100 V range: 110 V p-p Channels ±: 60 V p-p Channel/GND: 60 V p-p |
External Input *1 | Number of channels: Trigger of sampling (1 channel), or external sample inputs 1 ch logic/pulse (4 channel) Pulse input: Rotation count (RPM) mode, accumulating count mode*2 *2The pulse count mode counts the number of pulses per sample interval and converted to revolutions per minute Instant count mode Maximum input frequency: 50 kHz/Maximum count: 50 kc/sampling *1 Input/Output cable for GL option B-513 (sold separately) is required |
External Output*1 | Alarm output: 4 ch *1 Input/output cable for GL option B-513 (sold separately) is required |
Scaling Function | Analog channel, pulse channel |
Sampling Interval | 10 ms to 1 hour (10 to 50 ms: voltage only, limited number of CH) external signal A/D converter: ΔΣ type, 16 Bit (effective resolution: 1/40,000 of ± range) |
Maximum Sampling Interval of Up to 10 ms | Sampling Interval: 10 ms Number of CHs: 1 Measuring voltage: Yes Sampling Interval: 20 ms Number of CHs: 2 Measuring voltage: Yes Sampling Interval: 50 ms Number of CHs: 5 Measuring voltage: Yes Sampling Interval: 100 ms Number of CHs: 10 Measuring voltage: Yes Measuring temperature: Yes |
Storage | Built-in memory: Approximately 8 GB, SD card slot: 1 Medium*3: Data format: GBD/CSV *3Recorded in 2GB per file, SD cards available. Supported SDHC, up to approximately 32 GB memory Reliable long-term measurement: Recording time example (when only 10 analog channels are used, 2 GB recorded) Sampling interval: 10 ms GBD format: 41 days CSV format: 3 days Sampling interval: 50 ms GBD format: 88 days CSV format: 12 days Sampling interval: 100 ms GBD format: 103 days CSV format: 18 days Sampling interval: 200 ms GBD format: 207 days CSV format: 36 days Sampling interval: 500 ms GBD format: Over 365 days CSV format: 91 days Sampling interval: 1 second GBD format: Over 365 days CSV format: 182 days |
PC L/F | USB 2.0, wireless LAN optional item B-568 (sold separately) is required |
Capturing Mode | OFF (default), ring, relay |
Other Functions | Calculation function, trigger, alarm function, data backup function*4 *4If the ring setting and external sampling function is ON, the backup function is not available. If the backup destination is FTP, GL wireless LAN unit B-568 (sold separately) is required |
Display | 4.3" (10.9 cm) TFT (WQVGA: 480 x 272 dots) |
Software | Supported GL28-APS: OS Windows 11/10 PC for data logger settings, data recording, storage, playback Supported models: GL260/GL840/GL240 Connectable units/channels: Maximum 10 units/1000 ch GL-Connection: GL Series Integration Software PC for date logger settings, data recording, storage, playback Supported models: GL7000/GL2000/GL980/GL840GL240/GL260/GLT400 Connectable units: 20 Maximum 2000 ch |
Cloud Service G-remote | Supported OS: Windows 11/10 Supported WEB browser: Google Chrome (recommended), Microsoft Edge, Firefox (Internet browser supporting HTML5) Remote control service: Easy remote control and confirmation of measurement data from G-REMOTE on a browser via an Internet connection Data save service: Storing data on Graphtec cloud servers via Internet connection |
Environmental Conditions*5 | 32 to 113°F (0 to 45°C), 5 to 85% RH *5When operating with battery pack 32 to 113°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C) |
Calibration | NIST-CAL NIST calibration with certificate NIST-CAL-DATA NIST calibration with certificate and data ISO-17025-260 ISO-17025 calibration for GL260 |
Vibration Resistance | Equivalent to automobile parts Type 1 Class A |
Power | AC adaptor: AC 100 to 240 V/50 to 60 Hz DC input: DC 8.5 to 24 V (optional item B-514 is required) Battery pack: DC 7.2 V (2875 mAh) (optional item B-573 is required) Consumption: Maximum 36 VA (when AC 100 V) |
Dimensions | 7.4 x 4.6 x 1.7" (188 x 117 x 42 mm) |
Weight | 1.1 lbs (500g) (excluding AC adapter and battery pack) |
Click on a category to view a selection of compatible accessories with the GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V.
Analog Input | Number of channels: 10 channels/screw terminal (M3) Type: Scans channels for sampling, all channels isolated, balanced input Measurement range: Voltage: 20 mV to 100 V, 1 to 5 V F.S. Thermocouple: K, J, E, T, R, S, B, N, C (and the old W: WRe5-26) Humidity: 0 to 100%, optional item B-530 (sold separately) is required Filter: Off, 2, 5, 10, 20 (moving average in selected number) Maximum input voltage between ± terminal: 20 mV to 1 V range: 60 V p-p 2 to 100 V range: 110 V p-p Channels ±: 60 V p-p Channel/GND: 60 V p-p |
External Input *1 | Number of channels: Trigger of sampling (1 channel), or external sample inputs 1 ch logic/pulse (4 channel) Pulse input: Rotation count (RPM) mode, accumulating count mode*2 *2The pulse count mode counts the number of pulses per sample interval and converted to revolutions per minute Instant count mode Maximum input frequency: 50 kHz/Maximum count: 50 kc/sampling *1 Input/Output cable for GL option B-513 (sold separately) is required |
External Output*1 | Alarm output: 4 ch *1 Input/output cable for GL option B-513 (sold separately) is required |
Scaling Function | Analog channel, pulse channel |
Sampling Interval | 10 ms to 1 hour (10 to 50 ms: voltage only, limited number of CH) external signal A/D converter: ΔΣ type, 16 Bit (effective resolution: 1/40,000 of ± range) |
Maximum Sampling Interval of Up to 10 ms | Sampling Interval: 10 ms Number of CHs: 1 Measuring voltage: Yes Sampling Interval: 20 ms Number of CHs: 2 Measuring voltage: Yes Sampling Interval: 50 ms Number of CHs: 5 Measuring voltage: Yes Sampling Interval: 100 ms Number of CHs: 10 Measuring voltage: Yes Measuring temperature: Yes |
Storage | Built-in memory: Approximately 8 GB, SD card slot: 1 Medium*3: Data format: GBD/CSV *3Recorded in 2GB per file, SD cards available. Supported SDHC, up to approximately 32 GB memory Reliable long-term measurement: Recording time example (when only 10 analog channels are used, 2 GB recorded) Sampling interval: 10 ms GBD format: 41 days CSV format: 3 days Sampling interval: 50 ms GBD format: 88 days CSV format: 12 days Sampling interval: 100 ms GBD format: 103 days CSV format: 18 days Sampling interval: 200 ms GBD format: 207 days CSV format: 36 days Sampling interval: 500 ms GBD format: Over 365 days CSV format: 91 days Sampling interval: 1 second GBD format: Over 365 days CSV format: 182 days |
PC L/F | USB 2.0, wireless LAN optional item B-568 (sold separately) is required |
Capturing Mode | OFF (default), ring, relay |
Other Functions | Calculation function, trigger, alarm function, data backup function*4 *4If the ring setting and external sampling function is ON, the backup function is not available. If the backup destination is FTP, GL wireless LAN unit B-568 (sold separately) is required |
Display | 4.3" (10.9 cm) TFT (WQVGA: 480 x 272 dots) |
Software | Supported GL28-APS: OS Windows 11/10 PC for data logger settings, data recording, storage, playback Supported models: GL260/GL840/GL240 Connectable units/channels: Maximum 10 units/1000 ch GL-Connection: GL Series Integration Software PC for date logger settings, data recording, storage, playback Supported models: GL7000/GL2000/GL980/GL840GL240/GL260/GLT400 Connectable units: 20 Maximum 2000 ch |
Cloud Service G-remote | Supported OS: Windows 11/10 Supported WEB browser: Google Chrome (recommended), Microsoft Edge, Firefox (Internet browser supporting HTML5) Remote control service: Easy remote control and confirmation of measurement data from G-REMOTE on a browser via an Internet connection Data save service: Storing data on Graphtec cloud servers via Internet connection |
Environmental Conditions*5 | 32 to 113°F (0 to 45°C), 5 to 85% RH *5When operating with battery pack 32 to 113°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C) |
Calibration | NIST-CAL NIST calibration with certificate NIST-CAL-DATA NIST calibration with certificate and data ISO-17025-260 ISO-17025 calibration for GL260 |
Vibration Resistance | Equivalent to automobile parts Type 1 Class A |
Power | AC adaptor: AC 100 to 240 V/50 to 60 Hz DC input: DC 8.5 to 24 V (optional item B-514 is required) Battery pack: DC 7.2 V (2875 mAh) (optional item B-573 is required) Consumption: Maximum 36 VA (when AC 100 V) |
Dimensions | 7.4 x 4.6 x 1.7" (188 x 117 x 42 mm) |
Weight | 1.1 lbs (500g) (excluding AC adapter and battery pack) |
Click on a category to view a selection of compatible accessories with the GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V.