GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V

Model: GL260

GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V

Model: GL260

Compact and standalone, this improved data logger measures voltage, temperature, humidity, pulse, and logic signals using 10 input channels and faster update speed. Moreover, this logger features alarm history, calculations, a memory loop with 8 GB of data storage, and two software for easy operation and display.

Compact and standalone, this improved data logger measures voltage, temperature, humidity, pulse, and logic signals using 10 input channels and faster update speed. Moreover, this logger features alarm history, calculations, a memory loop with 8 GB of data storage, and two software for easy operation and display.

Your Price $1095.00 USD
Availability 3 in Stock
Quantity

GRAPHTEC GL260 Offers

Simple, portable, and versatile, this newly evolved datalogger introduces new features such as cloud access, alarm history function, enhanced CH to Ch calculation, memory loop function, and G-remote services. Acting as the replacement for the GL240, the GL260 showcases improved visibility, improved operability, improved functionality, new calculations, memory loop functions, software, and a new battery pack!

Features

  • Three new functions
  • Alarm history: Display of alarm history
  • This function shows the date/time history of alarm occurrence/cancellation
  • Usage: Easily check the alarm occurrence date and time with alarm history function
  • Actual screen: Easily check the CH and date of alarm occurrence at once
  • New calculation: Newly installed calculation CH coefficients can be used for CH calculations
  • Dedicated CHs for calculation is set up
  • Coefficients can now be used
  • Two types of calculation can be selected
  • The 4-point input enables temperature slope calculation output (allows adjustment of graph tilt)
  • Memory loop: Circulation recording is now possible in relay capturing
  • A new optional function of relay capturing that automatically deletes the oldest files before memory capacity runs out and continues recording
  • Ring capturing is a function that saves only the latest data of a specified number
  • Memory loop is a function that storages data using the memory of the recording destination to the maximum extent
  • Standard software: GL28-APS and GL-Connection
  • Gl28-APS: Check, record, and save waveforms on a pc with easy operation and versatile display
  • GL-Connection: Multiple GL series can be managed at once with focus on visibility and various waveform displays
  • New battery pack B-573
  • G-remote: Cloud server service, remote control service, data storage service
  • 4.3" (10.9 cm) TFT color LCD
  • Three visibility improvements
  • Display chromaticity: Improved screen saturation and increased chromaticity to improve visibility
  • Changed font: Added margins to improve visibility
  • Changed menu tree: Simplified the menu tree and made it more intuitive (menu key & file key)
  • Three operability improvements
  • Simplified waveform setting: Intuitive SPAN/POSI/TRACE operation
  • Web server function: Faster update speed
  • Auto span
  • HELP-QR function: QR code for more detailed information
  • Simplified waveform setting: SPAN/POSI/TRACE settings can now be configured in less steps
  • Display QR Code: Scan the QR code to see the related web page and check the detailed information
  • By scanning the QR code in each setting item, users can reach to information on the FAQ web page
  • Faster WEB server function: For smoother operation, CPU processing speed has been increased and settings screen has been renewed
  • Faster update speed: Smooth operation is now possible with faster processing speeds
  • New setup screen design: Install the same setup screen design as the logger (data in the loggers can be downloaded)
  • The game function has been restored aiming to familiarize users with key operations
  • Power supply: 8.5 to 24 V
  • USB-Type B

Applications

  • Aftermarket automotive tuning
  • Agriculture and food manufacturing
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive industry
  • Aerospace and military industry
  • Utilities/gas and electric
  • Battery manufacturing
  • Electrical appliance and office equipment
  • Electrical service and maintenance companies
  • Food processing
  • Rail transportation
  • Raw materials and components manufacturing
  • Research and development

GRAPHTEC GL260 Specifications

Analog Input Number of channels: 10 channels/screw terminal (M3)
Type: Scans channels for sampling, all channels isolated, balanced input

Measurement range:
Voltage: 20 mV to 100 V, 1 to 5 V F.S.
Thermocouple: K, J, E, T, R, S, B, N, C (and the old W: WRe5-26)
Humidity: 0 to 100%, optional item B-530 (sold separately) is required

Filter: Off, 2, 5, 10, 20 (moving average in selected number)

Maximum input voltage between ± terminal:
20 mV to 1 V range: 60 V p-p
2 to 100 V range: 110 V p-p

Channels ±: 60 V p-p
Channel/GND: 60 V p-p
External Input *1 Number of channels: Trigger of sampling (1 channel), or external sample inputs 1 ch logic/pulse (4 channel)
Pulse input: Rotation count (RPM) mode, accumulating count mode*2
*2The pulse count mode counts the number of pulses per sample interval and converted to revolutions per minute

Instant count mode
Maximum input frequency: 50 kHz/Maximum count: 50 kc/sampling
*1 Input/Output cable for GL option B-513 (sold separately) is required
External Output*1 Alarm output: 4 ch
*1 Input/output cable for GL option B-513 (sold separately) is required
Scaling Function Analog channel, pulse channel
Sampling Interval 10 ms to 1 hour (10 to 50 ms: voltage only, limited number of CH) external signal
A/D converter: ΔΣ type, 16 Bit (effective resolution: 1/40,000 of ± range)
Maximum Sampling Interval of Up to 10 ms Sampling Interval: 10 ms
Number of CHs: 1
Measuring voltage: Yes

Sampling Interval: 20 ms
Number of CHs: 2
Measuring voltage: Yes

Sampling Interval: 50 ms
Number of CHs: 5
Measuring voltage: Yes

Sampling Interval: 100 ms
Number of CHs: 10
Measuring voltage: Yes
Measuring temperature: Yes
Storage Built-in memory: Approximately 8 GB, SD card slot: 1
Medium*3: Data format: GBD/CSV
*3Recorded in 2GB per file, SD cards available. Supported SDHC, up to approximately 32 GB memory

Reliable long-term measurement:
Recording time example (when only 10 analog channels are used, 2 GB recorded)

Sampling interval: 10 ms
GBD format: 41 days
CSV format: 3 days

Sampling interval: 50 ms
GBD format: 88 days
CSV format: 12 days

Sampling interval: 100 ms
GBD format: 103 days
CSV format: 18 days

Sampling interval: 200 ms
GBD format: 207 days
CSV format: 36 days

Sampling interval: 500 ms
GBD format: Over 365 days
CSV format: 91 days

Sampling interval: 1 second
GBD format: Over 365 days
CSV format: 182 days
PC L/F USB 2.0, wireless LAN optional item B-568 (sold separately) is required
Capturing Mode OFF (default), ring, relay
Other Functions Calculation function, trigger, alarm function, data backup function*4
*4If the ring setting and external sampling function is ON, the backup function is not available. If the backup destination is FTP, GL wireless LAN unit B-568 (sold separately) is required
Display 4.3" (10.9 cm) TFT (WQVGA: 480 x 272 dots)
Software Supported GL28-APS: OS Windows 11/10
PC for data logger settings, data recording, storage, playback
Supported models: GL260/GL840/GL240
Connectable units/channels: Maximum 10 units/1000 ch

GL-Connection: GL Series Integration Software
PC for date logger settings, data recording, storage, playback
Supported models: GL7000/GL2000/GL980/GL840GL240/GL260/GLT400
Connectable units: 20
Maximum 2000 ch
Cloud Service G-remote Supported OS: Windows 11/10
Supported WEB browser: Google Chrome (recommended), Microsoft Edge, Firefox (Internet browser supporting HTML5)
Remote control service: Easy remote control and confirmation of measurement data from G-REMOTE on a browser via an Internet connection
Data save service: Storing data on Graphtec cloud servers via Internet connection
Environmental Conditions*5 32 to 113°F (0 to 45°C), 5 to 85% RH
*5When operating with battery pack 32 to 113°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C)
Calibration NIST-CAL NIST calibration with certificate
NIST-CAL-DATA NIST calibration with certificate and data
ISO-17025-260 ISO-17025 calibration for GL260
Vibration Resistance Equivalent to automobile parts Type 1 Class A
Power AC adaptor: AC 100 to 240 V/50 to 60 Hz
DC input: DC 8.5 to 24 V (optional item B-514 is required)
Battery pack: DC 7.2 V (2875 mAh) (optional item B-573 is required)
Consumption: Maximum 36 VA (when AC 100 V)
Dimensions 7.4 x 4.6 x 1.7" (188 x 117 x 42 mm)
Weight 1.1 lbs (500g) (excluding AC adapter and battery pack)
Click here for complete specifications on the GRAPHTEC GL260

What's included with the GRAPHTEC GL260

  • Data Logger
  • AC Adapter

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-514 DC Power Cable for the GL series, 6.56' B-514
Compatible with the GL series 900, 840, 820, 240, and 220, this 6.56' (2 m) power cable is an accessory.




GRAPHTEC TC-T-5 TC Adapter with mini-connector to M3 spade lugs, Type T, 12", 5-pack" TC-T-5
Connect quickly with ease using this 12" (30.4 cm) TC adapter type T mini-connector to M3 spade lugs to maintain the highest standards in thermocouple connections. In addition, this adapter prevents miswiring and preserves connection integrity.




GRAPHTEC TC-K-5 TC Adapter with mini-connector to M3 spade lugs, Type K, 12", 5-pack TC-K-5
Connect quickly with ease using this 12" (30.4 cm) TC adapter type K mini-connector to M3 spade lugs to maintain the highest standards in thermocouple connections. In addition, this adapter prevents miswiring and preserves connection integrity.




GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-573 Battery Pack for the GL260, 7.2 V, 2875 mAh B-573
Compatible with the GL260, this lithium battery pack carries a charge voltage of 7.2 V and capacity of 2875 mAh.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




GRAPHTEC B-551-10 Shunt Resistors, 250 ohm B-551-10
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use. It comes in a pack of 10




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-536US-260 Pelican Case with custom foam inserts for the GL260 B-536US-260
Specially designed IP67-rated pelican case for the GL260 data logger instruments and accessories. Furthermore, this case features protective rubber covers and foam inserts to ensure maximum protection.




GRAPHTEC GL260 Offers

Simple, portable, and versatile, this newly evolved datalogger introduces new features such as cloud access, alarm history function, enhanced CH to Ch calculation, memory loop function, and G-remote services. Acting as the replacement for the GL240, the GL260 showcases improved visibility, improved operability, improved functionality, new calculations, memory loop functions, software, and a new battery pack!

Features

  • Three new functions
  • Alarm history: Display of alarm history
  • This function shows the date/time history of alarm occurrence/cancellation
  • Usage: Easily check the alarm occurrence date and time with alarm history function
  • Actual screen: Easily check the CH and date of alarm occurrence at once
  • New calculation: Newly installed calculation CH coefficients can be used for CH calculations
  • Dedicated CHs for calculation is set up
  • Coefficients can now be used
  • Two types of calculation can be selected
  • The 4-point input enables temperature slope calculation output (allows adjustment of graph tilt)
  • Memory loop: Circulation recording is now possible in relay capturing
  • A new optional function of relay capturing that automatically deletes the oldest files before memory capacity runs out and continues recording
  • Ring capturing is a function that saves only the latest data of a specified number
  • Memory loop is a function that storages data using the memory of the recording destination to the maximum extent
  • Standard software: GL28-APS and GL-Connection
  • Gl28-APS: Check, record, and save waveforms on a pc with easy operation and versatile display
  • GL-Connection: Multiple GL series can be managed at once with focus on visibility and various waveform displays
  • New battery pack B-573
  • G-remote: Cloud server service, remote control service, data storage service
  • 4.3" (10.9 cm) TFT color LCD
  • Three visibility improvements
  • Display chromaticity: Improved screen saturation and increased chromaticity to improve visibility
  • Changed font: Added margins to improve visibility
  • Changed menu tree: Simplified the menu tree and made it more intuitive (menu key & file key)
  • Three operability improvements
  • Simplified waveform setting: Intuitive SPAN/POSI/TRACE operation
  • Web server function: Faster update speed
  • Auto span
  • HELP-QR function: QR code for more detailed information
  • Simplified waveform setting: SPAN/POSI/TRACE settings can now be configured in less steps
  • Display QR Code: Scan the QR code to see the related web page and check the detailed information
  • By scanning the QR code in each setting item, users can reach to information on the FAQ web page
  • Faster WEB server function: For smoother operation, CPU processing speed has been increased and settings screen has been renewed
  • Faster update speed: Smooth operation is now possible with faster processing speeds
  • New setup screen design: Install the same setup screen design as the logger (data in the loggers can be downloaded)
  • The game function has been restored aiming to familiarize users with key operations
  • Power supply: 8.5 to 24 V
  • USB-Type B

Applications

  • Aftermarket automotive tuning
  • Agriculture and food manufacturing
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive industry
  • Aerospace and military industry
  • Utilities/gas and electric
  • Battery manufacturing
  • Electrical appliance and office equipment
  • Electrical service and maintenance companies
  • Food processing
  • Rail transportation
  • Raw materials and components manufacturing
  • Research and development

GRAPHTEC GL260 Specifications

Analog Input Number of channels: 10 channels/screw terminal (M3)
Type: Scans channels for sampling, all channels isolated, balanced input

Measurement range:
Voltage: 20 mV to 100 V, 1 to 5 V F.S.
Thermocouple: K, J, E, T, R, S, B, N, C (and the old W: WRe5-26)
Humidity: 0 to 100%, optional item B-530 (sold separately) is required

Filter: Off, 2, 5, 10, 20 (moving average in selected number)

Maximum input voltage between ± terminal:
20 mV to 1 V range: 60 V p-p
2 to 100 V range: 110 V p-p

Channels ±: 60 V p-p
Channel/GND: 60 V p-p
External Input *1 Number of channels: Trigger of sampling (1 channel), or external sample inputs 1 ch logic/pulse (4 channel)
Pulse input: Rotation count (RPM) mode, accumulating count mode*2
*2The pulse count mode counts the number of pulses per sample interval and converted to revolutions per minute

Instant count mode
Maximum input frequency: 50 kHz/Maximum count: 50 kc/sampling
*1 Input/Output cable for GL option B-513 (sold separately) is required
External Output*1 Alarm output: 4 ch
*1 Input/output cable for GL option B-513 (sold separately) is required
Scaling Function Analog channel, pulse channel
Sampling Interval 10 ms to 1 hour (10 to 50 ms: voltage only, limited number of CH) external signal
A/D converter: ΔΣ type, 16 Bit (effective resolution: 1/40,000 of ± range)
Maximum Sampling Interval of Up to 10 ms Sampling Interval: 10 ms
Number of CHs: 1
Measuring voltage: Yes

Sampling Interval: 20 ms
Number of CHs: 2
Measuring voltage: Yes

Sampling Interval: 50 ms
Number of CHs: 5
Measuring voltage: Yes

Sampling Interval: 100 ms
Number of CHs: 10
Measuring voltage: Yes
Measuring temperature: Yes
Storage Built-in memory: Approximately 8 GB, SD card slot: 1
Medium*3: Data format: GBD/CSV
*3Recorded in 2GB per file, SD cards available. Supported SDHC, up to approximately 32 GB memory

Reliable long-term measurement:
Recording time example (when only 10 analog channels are used, 2 GB recorded)

Sampling interval: 10 ms
GBD format: 41 days
CSV format: 3 days

Sampling interval: 50 ms
GBD format: 88 days
CSV format: 12 days

Sampling interval: 100 ms
GBD format: 103 days
CSV format: 18 days

Sampling interval: 200 ms
GBD format: 207 days
CSV format: 36 days

Sampling interval: 500 ms
GBD format: Over 365 days
CSV format: 91 days

Sampling interval: 1 second
GBD format: Over 365 days
CSV format: 182 days
PC L/F USB 2.0, wireless LAN optional item B-568 (sold separately) is required
Capturing Mode OFF (default), ring, relay
Other Functions Calculation function, trigger, alarm function, data backup function*4
*4If the ring setting and external sampling function is ON, the backup function is not available. If the backup destination is FTP, GL wireless LAN unit B-568 (sold separately) is required
Display 4.3" (10.9 cm) TFT (WQVGA: 480 x 272 dots)
Software Supported GL28-APS: OS Windows 11/10
PC for data logger settings, data recording, storage, playback
Supported models: GL260/GL840/GL240
Connectable units/channels: Maximum 10 units/1000 ch

GL-Connection: GL Series Integration Software
PC for date logger settings, data recording, storage, playback
Supported models: GL7000/GL2000/GL980/GL840GL240/GL260/GLT400
Connectable units: 20
Maximum 2000 ch
Cloud Service G-remote Supported OS: Windows 11/10
Supported WEB browser: Google Chrome (recommended), Microsoft Edge, Firefox (Internet browser supporting HTML5)
Remote control service: Easy remote control and confirmation of measurement data from G-REMOTE on a browser via an Internet connection
Data save service: Storing data on Graphtec cloud servers via Internet connection
Environmental Conditions*5 32 to 113°F (0 to 45°C), 5 to 85% RH
*5When operating with battery pack 32 to 113°F (0 to 40°C), charging battery 59 to 95°F (15 to 35°C)
Calibration NIST-CAL NIST calibration with certificate
NIST-CAL-DATA NIST calibration with certificate and data
ISO-17025-260 ISO-17025 calibration for GL260
Vibration Resistance Equivalent to automobile parts Type 1 Class A
Power AC adaptor: AC 100 to 240 V/50 to 60 Hz
DC input: DC 8.5 to 24 V (optional item B-514 is required)
Battery pack: DC 7.2 V (2875 mAh) (optional item B-573 is required)
Consumption: Maximum 36 VA (when AC 100 V)
Dimensions 7.4 x 4.6 x 1.7" (188 x 117 x 42 mm)
Weight 1.1 lbs (500g) (excluding AC adapter and battery pack)
Click here for complete specifications on the GRAPHTEC GL260

What's included with the GRAPHTEC GL260

  • Data Logger
  • AC Adapter

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL260 Data Logger, 10 channels, 20 mV to 100 V.

GRAPHTEC B-513 Input/Output Cable for the GL series, 6.56', bare tips B-513
Compatible with the GL series data application software, the input/output cable has bare tips and a length of 6.56168' (2 m).




GRAPHTEC B-514 DC Power Cable for the GL series, 6.56' B-514
Compatible with the GL series 900, 840, 820, 240, and 220, this 6.56' (2 m) power cable is an accessory.




GRAPHTEC TC-T-5 TC Adapter with mini-connector to M3 spade lugs, Type T, 12", 5-pack" TC-T-5
Connect quickly with ease using this 12" (30.4 cm) TC adapter type T mini-connector to M3 spade lugs to maintain the highest standards in thermocouple connections. In addition, this adapter prevents miswiring and preserves connection integrity.




GRAPHTEC TC-K-5 TC Adapter with mini-connector to M3 spade lugs, Type K, 12", 5-pack TC-K-5
Connect quickly with ease using this 12" (30.4 cm) TC adapter type K mini-connector to M3 spade lugs to maintain the highest standards in thermocouple connections. In addition, this adapter prevents miswiring and preserves connection integrity.




GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-573 Battery Pack for the GL260, 7.2 V, 2875 mAh B-573
Compatible with the GL260, this lithium battery pack carries a charge voltage of 7.2 V and capacity of 2875 mAh.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




GRAPHTEC B-551-10 Shunt Resistors, 250 ohm B-551-10
Featuring a shunt resistance of 250 Ω, the shunt resistor is soldered on lugs for terminal block use. It comes in a pack of 10




GRAPHTEC B-530 Humidity Sensor, -25 to 80°C B-530
Comes with a 3 m length cable, the humidity sensor with a dedicated power connector has an allowable temperature range of -25 to 80°C.




GRAPHTEC B-536US-260 Pelican Case with custom foam inserts for the GL260 B-536US-260
Specially designed IP67-rated pelican case for the GL260 data logger instruments and accessories. Furthermore, this case features protective rubber covers and foam inserts to ensure maximum protection.




More GRAPHTEC Products