HD2,w/o LCD,Analog,2%RH,Temp Transmitter
HD2,w/o LCD,Analog,2%RH,Temp Transmitter
HD2 Series Analog Humidity Sensors are duct-mounted devices that measure both humidity and temperature with solid-state sensors. They ensure accurate readings, improve energy efficiency, and help maintain proper building conditions. Each unit provides analog outputs (4-20mA, 0-5 VDC, or 0-10 VDC) and features a field-replaceable humidity sensor.
Features
| Agency Approvals | UL 916; CE: EN61000-6-2, EN61000-6-3, EN61000 Series, immunity, EN 61326-1; FCC Part 15 Class A; REACH, RoHS, RoHS 2 (China), RCM (Australia), ICES-003 (Canada), UKCA (UK) |
| Collection | Plant Room Air Quality Sensors |
| Enclosure Material | Polycarbonate; flammability rating UL 94 V0 |
| Humidity Calibration Certificate | Replaceable RH element available in 1% & 2% with NISTcalibration certificate |
| Humidity Measurement Accuracy | ±2% from 10 to 80% RH @ 25°C (77 °F) |
| Humidity Measurement Linearity | Included in accuracy specification |
| Humidity Measurement Resolution | 0.1% RH |
| Humidity Output Range | 0 to 100% RH |
| Humidity Sensor Type | Solid state capacitive, replaceable |
| IP Protection | IP65 |
| Input Specifications | 3-wire volt mode: 20 to 30 Vdc, 24 Vac, 50 to 60 Hz; loop powered: 20 to 30 Vdc |
| Measurement Type | Relative Humidity / Temperature |
| Operating Humidity | 0 to 95% RH non-condensing |
| Operating Temperature | -35 to 60 °C (-31 to 140 °F) |
| Output Specifications | Selectable 4 To 20 MA, 0 To 5 V, 0 To 10 V |
| Outputs | Analog Output |
| Temperature Measurement Accuracy | ±0.2 °C (±0.4 °F) typical |
| Temperature Measurement Range | -35 to 60 °C (-31 to 140 °F) |
| Temperature Measurement Resolution | 0.1 °C (0.1 °F) |
| Temperature Sensor Type | Transmitter |
| Terminal Blocks | Screwless terminal block with spring actuator, 16-24 AWG |
| Agency Approvals | UL 916; CE: EN61000-6-2, EN61000-6-3, EN61000 Series, immunity, EN 61326-1; FCC Part 15 Class A; REACH, RoHS, RoHS 2 (China), RCM (Australia), ICES-003 (Canada), UKCA (UK) |
| Collection | Plant Room Air Quality Sensors |
| Enclosure Material | Polycarbonate; flammability rating UL 94 V0 |
| Humidity Calibration Certificate | Replaceable RH element available in 1% & 2% with NISTcalibration certificate |
| Humidity Measurement Accuracy | ±2% from 10 to 80% RH @ 25°C (77 °F) |
| Humidity Measurement Linearity | Included in accuracy specification |
| Humidity Measurement Resolution | 0.1% RH |
| Humidity Output Range | 0 to 100% RH |
| Humidity Sensor Type | Solid state capacitive, replaceable |
| IP Protection | IP65 |
| Input Specifications | 3-wire volt mode: 20 to 30 Vdc, 24 Vac, 50 to 60 Hz; loop powered: 20 to 30 Vdc |
| Measurement Type | Relative Humidity / Temperature |
| Operating Humidity | 0 to 95% RH non-condensing |
| Operating Temperature | -35 to 60 °C (-31 to 140 °F) |
| Output Specifications | Selectable 4 To 20 MA, 0 To 5 V, 0 To 10 V |
| Outputs | Analog Output |
| Temperature Measurement Accuracy | ±0.2 °C (±0.4 °F) typical |
| Temperature Measurement Range | -35 to 60 °C (-31 to 140 °F) |
| Temperature Measurement Resolution | 0.1 °C (0.1 °F) |
| Temperature Sensor Type | Transmitter |
| Terminal Blocks | Screwless terminal block with spring actuator, 16-24 AWG |