The single-circuit, Lonmark certified meter can be easily installed on a standard DIN rail or surface mounted in an optional NEMA 4 enclosure as needed. A front-panel LCD makes device installation and setup easy and provides local access to the full set of detailed measurements.
The single-circuit, Lonmark certified meter can be easily installed on a standard DIN rail or surface mounted in an optional NEMA 4 enclosure as needed. A front-panel LCD makes device installation and setup easy and provides local access to the full set of detailed measurements.
The single-circuit, Lonmark certified meter can be easily installed on a standard DIN rail or surface mounted in an optional NEMA 4 enclosure as needed. A front-panel LCD makes device installation and setup easy and provides local access to the full set of detailed measurements.
Features
Applications
| Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
| Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
| Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
| Scaling | 5 to 32,000 A |
| Input Range | 0 to 0.333 V or 0 to 1 V (selectable); CTs must be rated for use with Class 1 voltage inputs |
| Pulse Inputs (E5xHx and E50Fx Only) | Contact inputs to pulse accumulators (1 set with E5xH2 and E50F2; 2 sets with E5xH5 and E51F5) |
| Real Power and Energy | 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S) |
| Mounting Location | DIN Rail or 3-point screw mount |
| Altitude of Operation | 9,842.5' (3,000 m) |
| Operating Temp Range | -22 to 158°F (-30 to 70°C) |
| Storage Temp Range | -40 to 185°F (-40 to 85°C) |
| Humidity Range | <95% RH non-condensing |
| Mounting Location | Not suitable for wet locations; for indoor use only |
| Warranty | 5 years limited |
| Agency Approvals | UL 508 (Open Type Device), IEC/EN 61010-1, California CSI Solar, ANSI C12.20, Cat III, Pollution Degree 2 |
| Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
| Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
| Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
| Scaling | 5 to 32,000 A |
| Input Range | 0 to 0.333 V or 0 to 1 V (selectable); CTs must be rated for use with Class 1 voltage inputs |
| Pulse Inputs (E5xHx and E50Fx Only) | Contact inputs to pulse accumulators (1 set with E5xH2 and E50F2; 2 sets with E5xH5 and E51F5) |
| Real Power and Energy | 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S) |
| Mounting Location | DIN Rail or 3-point screw mount |
| Altitude of Operation | 9,842.5' (3,000 m) |
| Operating Temp Range | -22 to 158°F (-30 to 70°C) |
| Storage Temp Range | -40 to 185°F (-40 to 85°C) |
| Humidity Range | <95% RH non-condensing |
| Mounting Location | Not suitable for wet locations; for indoor use only |
| Warranty | 5 years limited |
| Agency Approvals | UL 508 (Open Type Device), IEC/EN 61010-1, California CSI Solar, ANSI C12.20, Cat III, Pollution Degree 2 |