TSI Alnor 800873 Micromanometer Unit

Model: 800873

TSI Alnor 800873 Micromanometer Unit

Model: 800873

The micromanometer can measure pressure, velocity and flow. It also offers automatic density correction.

The micromanometer can measure pressure, velocity and flow. It also offers automatic density correction.

Sale Price $1850.00 USD
Regular Price $2055.00 USD
Availability 3 to 4 Weeks
Quantity

TSI/Alnor 800873 Offers

The TSI/Alnor 800873 Micromanometer Unit is ideal for the EBT730 and EBT731 balometer kits. It accurately measures pressure, velocity and flow, and it has an auto-zeroing pressure sensor along with automatic density correction.

Features

  • Optimized for a high level of accuracy
  • Measures pressure, velocity and flow
  • Complete with an auto-zeroing pressure sensor
  • Offers automatic density correction

Applications

  • EBT730 and EBT731 balometer kits

TSI/Alnor 800873 Specifications

Velocity Range
Flow Probes and Sensors Pitot Probes: 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe: 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix: 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Units ft/min, m/s
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 in. H2O (±3735 Pa); 150 in. H2O (37.5 kPa), maximum safe operating pressure
Absolute Pressure 15 to 40 in. Hg (356 to 1016 mm Hg)
Accuracy ±2% of reading ±0.0001 in. H2O (±0.025 Pa) static and differential; ±2% of reading absolute
Units in. H2O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H2O, cm H2O
Resolution 0.00001 in. H2O (0.001 Pa) static and differential; 0.01 in. Hg (1 mm Hg) absolute
Volume
Range 25 to 2,500 ft3/min (42 to 4250 m3/h) capture hood
Accuracy ±3% of reading ±7 ft3/min (±12 m3/h) at flows >50 ft3/min (>85 m3/h)
Units ft3/min, m3/h, m3/min, l/s
Resolution 1 ft3/min (1 m3/h)
RH
Range 5 to 95% RH temperature/RH probe
Accuracy ±3% RH
Resolution 0.1% RH
Temperature
Accuracy ±0.5°F (±0.3°C)
Units °F,°C
Resolution 0.1°F (0.1°C)
Operating and Storage Sensor in base: 40 to 140°F (4.4 to 60°C)
Temperature/RH probe: 14 to 140°F (-10 to 60°C)
Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
General Specifications
Compatibility EBT730 and EBT731 balometer kits
Statistics min, max, average
Data Storage 26,500 samples, time and date stamped
Logging Interval User selectable
Response Time 2 to 8 seconds, differential pressure sensor
Pressure Connection 1/4in. (6.35 mm) OD straight ports with barbed ends for use with 3/16in. (4.76 mm) ID flexible tubing
Power Requirements Four AA-size cells or AC adapter
Dimensions 7.4 x 4.5 x 2.3" (18.8 x 11.4 x 5.8 cm) - manometer only
Weight 17 oz (0.5 kg), with batteries
Click here for complete specifications on the TSI/Alnor 800873

What's included with the TSI/Alnor 800873

  • Micromanometer
  • Neoprene Tubing 16' (4.8 m)
  • Pitot Probe 18" (46 cm)
  • 2 x Static Pressure Probes
  • Multi-country AC Adapter
  • USB Interface Cable
  • Downloading Software
  • Manual
  • Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • NIST-traceable Calibration Certificate

TSI/Alnor 800873 Offers

The TSI/Alnor 800873 Micromanometer Unit is ideal for the EBT730 and EBT731 balometer kits. It accurately measures pressure, velocity and flow, and it has an auto-zeroing pressure sensor along with automatic density correction.

Features

  • Optimized for a high level of accuracy
  • Measures pressure, velocity and flow
  • Complete with an auto-zeroing pressure sensor
  • Offers automatic density correction

Applications

  • EBT730 and EBT731 balometer kits

TSI/Alnor 800873 Specifications

Velocity Range
Flow Probes and Sensors Pitot Probes: 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe: 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix: 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Units ft/min, m/s
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 in. H2O (±3735 Pa); 150 in. H2O (37.5 kPa), maximum safe operating pressure
Absolute Pressure 15 to 40 in. Hg (356 to 1016 mm Hg)
Accuracy ±2% of reading ±0.0001 in. H2O (±0.025 Pa) static and differential; ±2% of reading absolute
Units in. H2O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H2O, cm H2O
Resolution 0.00001 in. H2O (0.001 Pa) static and differential; 0.01 in. Hg (1 mm Hg) absolute
Volume
Range 25 to 2,500 ft3/min (42 to 4250 m3/h) capture hood
Accuracy ±3% of reading ±7 ft3/min (±12 m3/h) at flows >50 ft3/min (>85 m3/h)
Units ft3/min, m3/h, m3/min, l/s
Resolution 1 ft3/min (1 m3/h)
RH
Range 5 to 95% RH temperature/RH probe
Accuracy ±3% RH
Resolution 0.1% RH
Temperature
Accuracy ±0.5°F (±0.3°C)
Units °F,°C
Resolution 0.1°F (0.1°C)
Operating and Storage Sensor in base: 40 to 140°F (4.4 to 60°C)
Temperature/RH probe: 14 to 140°F (-10 to 60°C)
Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
General Specifications
Compatibility EBT730 and EBT731 balometer kits
Statistics min, max, average
Data Storage 26,500 samples, time and date stamped
Logging Interval User selectable
Response Time 2 to 8 seconds, differential pressure sensor
Pressure Connection 1/4in. (6.35 mm) OD straight ports with barbed ends for use with 3/16in. (4.76 mm) ID flexible tubing
Power Requirements Four AA-size cells or AC adapter
Dimensions 7.4 x 4.5 x 2.3" (18.8 x 11.4 x 5.8 cm) - manometer only
Weight 17 oz (0.5 kg), with batteries
Click here for complete specifications on the TSI/Alnor 800873

What's included with the TSI/Alnor 800873

  • Micromanometer
  • Neoprene Tubing 16' (4.8 m)
  • Pitot Probe 18" (46 cm)
  • 2 x Static Pressure Probes
  • Multi-country AC Adapter
  • USB Interface Cable
  • Downloading Software
  • Manual
  • Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • NIST-traceable Calibration Certificate