Capture precise production metrics across a vast range of industrial power supplies. This highly adaptable digital tracking device seamlessly interfaces with diverse automated machinery, ensuring reliable cycle monitoring for complex setups.
Capture precise production metrics across a vast range of industrial power supplies. This highly adaptable digital tracking device seamlessly interfaces with diverse automated machinery, ensuring reliable cycle monitoring for complex setups.
The 7111 and 7111HV are compact, self-powered counters with bi-directional counting. It is a dry contact input counter that counts up to 10 kHz and features contact closure / open collector low speed count input with integral de-bounce circuitry. It uses a wide ranging voltage counter that triggers from any voltage between 10 to 240 V AC or 10 to 110 V DC.
Features
Applications
| External Reset | 10 to 110 V DC ±10%, 10 to 240 V AC ±10%, 50 mS minimum length |
| Direction Input | Connection or electronic input TTL/CMOS compatible Add = no connection or >2.4 v (logic 1) Subtract = connect to COMMON or <0.7 v Direction input must precede count input by 5 μS (minimum) for valid operation. Maximum 18 V DC |
| Count Input | 10 to 110 V DC ±10%, 10 to 240 V AC ±10%, 50 mS minimum pulse width, 10 Hz |
| Battery | Non-replaceable Lithium battery, expected life of 10 years at 68°F (20°C) |
| Display | 8-digit black LCD, 0.35" (9 mm) characters, leading zero blanking, backlight requires an external 5 V DC supply. Configurable decimal place up to 3 decimal place |
| Count Range | 99,999,999 - rollover to 0 |
| Connections | Finger-proof screw connections for cables up to 1.5 mm2 |
| Temperature | Operating: 14 to 140°F (-10 to 60°C) Storage: -4 to 140°F (-20 to 60°C) |
| Altitude | Up to 6562' (2000 m) |
| Relative Humidity | 80% maximum up to 87.8°F (31°C), decreasing to 50% maximum at 104°F (40°C) |
| Sealing | IP65/NEMA4X |
| Mounting | Either with clip mount supplied or two front screws with bezel supplied |
| Manual Reset Enable | Configured by jumper link |
| Dimensions | 2.2 x 1.73 x 2.44" (56 x 44 x 62 mm) |
| Weight | 2.19 oz (62 g) |
| External Reset | 10 to 110 V DC ±10%, 10 to 240 V AC ±10%, 50 mS minimum length |
| Direction Input | Connection or electronic input TTL/CMOS compatible Add = no connection or >2.4 v (logic 1) Subtract = connect to COMMON or <0.7 v Direction input must precede count input by 5 μS (minimum) for valid operation. Maximum 18 V DC |
| Count Input | 10 to 110 V DC ±10%, 10 to 240 V AC ±10%, 50 mS minimum pulse width, 10 Hz |
| Battery | Non-replaceable Lithium battery, expected life of 10 years at 68°F (20°C) |
| Display | 8-digit black LCD, 0.35" (9 mm) characters, leading zero blanking, backlight requires an external 5 V DC supply. Configurable decimal place up to 3 decimal place |
| Count Range | 99,999,999 - rollover to 0 |
| Connections | Finger-proof screw connections for cables up to 1.5 mm2 |
| Temperature | Operating: 14 to 140°F (-10 to 60°C) Storage: -4 to 140°F (-20 to 60°C) |
| Altitude | Up to 6562' (2000 m) |
| Relative Humidity | 80% maximum up to 87.8°F (31°C), decreasing to 50% maximum at 104°F (40°C) |
| Sealing | IP65/NEMA4X |
| Mounting | Either with clip mount supplied or two front screws with bezel supplied |
| Manual Reset Enable | Configured by jumper link |
| Dimensions | 2.2 x 1.73 x 2.44" (56 x 44 x 62 mm) |
| Weight | 2.19 oz (62 g) |