Seamlessly monitor machine cycles and operational duration with this compact, electrically driven panel module. Engineered for versatile setups in industrial control systems, it delivers precise operational metrics to optimize maintenance schedules and improve equipment efficiency.
Seamlessly monitor machine cycles and operational duration with this compact, electrically driven panel module. Engineered for versatile setups in industrial control systems, it delivers precise operational metrics to optimize maintenance schedules and improve equipment efficiency.
The 52U0 is a voltage-powered dual-function counter with 4 functions in one device: counter with 2 totalizing range, totalizer and timer, totalizer and frequency meter, timer with 2 time ranges. For fast and slow count pulses, with a 6-digit LED display for NPN, PNP input signals.
The 52U0 is a versatile unit for a range of applications, with a fast count and frequency input - input frequency max. 60 kHz (can be damped to 30 Hz for mechanical contacts) - robust IP65 housing and LED display. It provides a very accurate, precise frequency measurement principle (HRA-High Rate Accuracy System) with frequencies up to 38 Hz, calculated using time-interval (period duration) measurement. Frequencies of > 38 Hz are calculated using a special time base (gate time) measurement, and a very high accuracy of <0.1% is achieved, even with very short gate times. The resulting measurement is available after a maximum of 50 ms.
Features
Applications
| Display | 6 digits, red 7-segment LED display 8 mm (0.32") high |
| Data Backup | EEPROM |
| Operating Temperature non-Condensing |
10 to 26 V DC: -4 to 149°F (-20 to 65°C) >26 to 60 V DC: -4 to 131°F (-20 to 55°C) |
| Storage Temperature | -13 to 158°F (-25 to 70°C) |
| Vibration Resistance | 10 to 55 Hz / 0.04" (1 mm) / 30 min |
| Shock Resistance | 100 G: 2 ms 10 G: 6 ms |
| Polarity of Inputs | Programmable, NPN or PN |
| Input Resistance | Approximately 5 kΩ |
| Power Supply | 10 to 30 V DC, with integrated reverse polarity protection |
| Counting Frequency | Maximum 60 kHz, can be damped to 30 Hz |
| Current Consumption | Maximum 40 mA |
| Display Range | Timer: 0.001 s to 999,999 h Frequency meter: 1/min or 1/sec |
| Minimum Pulse Duration of Reset Input | 5 ms |
| Input Switching Level (HTL) | LOW 0 to 0.2 x UB (V DC) HIGH 0.6 x UB - 30 V DC |
| Input Switching Level at 4 to 30 V DC | LOW 0 to 2 V DC HIGH 4 to 30 V DC |
| Accuracy | <0.1% frequency meter, tachometer |
| EMC Standards | EN 55011 class B, EN 61000-6-2, EN 61000-6-3 EN 61326-1 |
| UL Standards | E128604 |
| Housing | Front panel mount 1.89 x 0.94" (48 x 24 mm) acc. to DIN 43700, RAL 7021, dark grey |
| Protection | IP65 (front side) |
| Weight | 1.76 oz (50 g) |
| Display | 6 digits, red 7-segment LED display 8 mm (0.32") high |
| Data Backup | EEPROM |
| Operating Temperature non-Condensing |
10 to 26 V DC: -4 to 149°F (-20 to 65°C) >26 to 60 V DC: -4 to 131°F (-20 to 55°C) |
| Storage Temperature | -13 to 158°F (-25 to 70°C) |
| Vibration Resistance | 10 to 55 Hz / 0.04" (1 mm) / 30 min |
| Shock Resistance | 100 G: 2 ms 10 G: 6 ms |
| Polarity of Inputs | Programmable, NPN or PN |
| Input Resistance | Approximately 5 kΩ |
| Power Supply | 10 to 30 V DC, with integrated reverse polarity protection |
| Counting Frequency | Maximum 60 kHz, can be damped to 30 Hz |
| Current Consumption | Maximum 40 mA |
| Display Range | Timer: 0.001 s to 999,999 h Frequency meter: 1/min or 1/sec |
| Minimum Pulse Duration of Reset Input | 5 ms |
| Input Switching Level (HTL) | LOW 0 to 0.2 x UB (V DC) HIGH 0.6 x UB - 30 V DC |
| Input Switching Level at 4 to 30 V DC | LOW 0 to 2 V DC HIGH 4 to 30 V DC |
| Accuracy | <0.1% frequency meter, tachometer |
| EMC Standards | EN 55011 class B, EN 61000-6-2, EN 61000-6-3 EN 61326-1 |
| UL Standards | E128604 |
| Housing | Front panel mount 1.89 x 0.94" (48 x 24 mm) acc. to DIN 43700, RAL 7021, dark grey |
| Protection | IP65 (front side) |
| Weight | 1.76 oz (50 g) |