Adding wireless ear-defender headphones for listening to bearing noise, this 9080K2 kit combines the Bluetooth smart trend meter, strobe, protective boot, and A9084 VibTrend Pro software. It measures 2 Hz to 1 kHz (ISO) and 1 to 10 kHz bearing (BDU) with an 800-line spectrum to diagnoses unbalance, misalignment, and looseness on rotating machinery.
Adding wireless ear-defender headphones for listening to bearing noise, this 9080K2 kit combines the Bluetooth smart trend meter, strobe, protective boot, and A9084 VibTrend Pro software. It measures 2 Hz to 1 kHz (ISO) and 1 to 10 kHz bearing (BDU) with an 800-line spectrum to diagnoses unbalance, misalignment, and looseness on rotating machinery.
Collect precise data with help from this Vibration Analyzer Kit with wireless headphones. For simple pairing, the headphones connect via Bluetooth and the VibTrend Pro software allows you to record ten measurement points per asset to help ensure accurate monitoring.
Features
Applications
| Frequency Range | 2 Hz to 1 kHz (ISO) 1 to 10 kHz (BDU) |
| Maximum Frequency Resolution | 1.25 Hz at 800 lines FFT setting Acceleration in g Velocity in mm/s (or inch/s) Bearing noise in BDU (bearing damage units) Displacement (mm, microns, inch) |
| Displayed Frequency Units | Hz, RPM or CPM |
| Input Range | User selectable with accelerometer sensitivity |
| Dynamic Range | 96 dB (0.01 g resolution) |
| VA Diagnostic Bands (RPM = run speed) | Unbalance 1x RPM Alignment 2x RPM Looseness 3x RPM |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Waterproof | IP67 |
| Power Supply | 2 x AA batteries |
| Battery life | Auto power OFF - typically 20 hours continuous operating time depending on brightness setting |
| Dimensions | 7.8 x 2.3 x 1” (200 x 60 x 26 mm) |
| Weight | 0.6 lbs (280 g) |
| Frequency Range | 2 Hz to 1 kHz (ISO) 1 to 10 kHz (BDU) |
| Maximum Frequency Resolution | 1.25 Hz at 800 lines FFT setting Acceleration in g Velocity in mm/s (or inch/s) Bearing noise in BDU (bearing damage units) Displacement (mm, microns, inch) |
| Displayed Frequency Units | Hz, RPM or CPM |
| Input Range | User selectable with accelerometer sensitivity |
| Dynamic Range | 96 dB (0.01 g resolution) |
| VA Diagnostic Bands (RPM = run speed) | Unbalance 1x RPM Alignment 2x RPM Looseness 3x RPM |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Waterproof | IP67 |
| Power Supply | 2 x AA batteries |
| Battery life | Auto power OFF - typically 20 hours continuous operating time depending on brightness setting |
| Dimensions | 7.8 x 2.3 x 1” (200 x 60 x 26 mm) |
| Weight | 0.6 lbs (280 g) |