Measuring -58 to 284°F to ±0.18°F on a rigid 4.5" (115 mm) probe, this data logger reaches the cold spot inside large containers and packed loads. In addition, HACCP International certification supports audit documentation for food safety programs. Sealed stainless steel and PEEK construction carries an IP68 rating.
Measuring -58 to 284°F to ±0.18°F on a rigid 4.5" (115 mm) probe, this data logger reaches the cold spot inside large containers and packed loads. In addition, HACCP International certification supports audit documentation for food safety programs. Sealed stainless steel and PEEK construction carries an IP68 rating.
Qualifying a thermal process means placing a sensor exactly where the process is hardest to reach. This T2 logger carries a rigid probe 4.5" (115 mm) long, measuring -58 to 284°F (-50 to 140°C) with an accuracy of ±0.18°F (±0.1°C) over most of that span.
Built for the chamber, not the bench
Hermetically sealed measuring technology sits in a stainless steel and PEEK housing rated IP68, so the logger survives repeated wet, pressurized and sub-zero cycles. At 0.79" (20 mm) across it fits recesses, packed loads and container necks that larger instruments cannot enter.
Battery changes in seconds
The threaded battery screws on by hand and changes without tools, and the logger remains fully sealed afterwards. Data is read out through the multifunction case, which programs and downloads up to eight loggers at once using testo 191 professional software for HACCP-ready documentation.
Features
Applications
| Measurement Parameter | Temperature (Pt1000) |
| Measuring Range | -58 to 284°F (-50 to 140°C) |
| Accuracy | ±0.36°F (±0.2°C) from -58 to -40°F (-50 to -40°C) ±0.18°F (±0.1°C) from -40 to 284°F (-40 to 140°C) |
| Resolution | 0.01 °C |
| Reaction Time | t90 = 6 seconds |
| Probe Shaft | Ø0.12 x 4.5" (Ø3 x 115 mm) |
| Channels | 1 |
| Memory | 60,000 measuring values |
| Measuring Rate | 1 second to 24 hours |
| Operating Temperature | -58 to 284°F (-50 to 140°C) |
| Storage Temperature | -4 to 122°F (-20 to 50°C) |
| Dimensions | Ø0.79 x 2.3" (Ø20 x 59 mm) |
| Housing Material | Stainless steel, PEEK plastic |
| Protection Class | IP68 |
| Battery Type | 1/2 AA lithium |
| Battery Service Life | 750 operating hours (measuring cycle 10 seconds at 250°F (121°C)) |
| Authorizations | CE |
Click on a category to view a selection of compatible accessories with the Testo 191-T2 HACCP Temperature Data Logger with rigid probe, 115 mm.
| Measurement Parameter | Temperature (Pt1000) |
| Measuring Range | -58 to 284°F (-50 to 140°C) |
| Accuracy | ±0.36°F (±0.2°C) from -58 to -40°F (-50 to -40°C) ±0.18°F (±0.1°C) from -40 to 284°F (-40 to 140°C) |
| Resolution | 0.01 °C |
| Reaction Time | t90 = 6 seconds |
| Probe Shaft | Ø0.12 x 4.5" (Ø3 x 115 mm) |
| Channels | 1 |
| Memory | 60,000 measuring values |
| Measuring Rate | 1 second to 24 hours |
| Operating Temperature | -58 to 284°F (-50 to 140°C) |
| Storage Temperature | -4 to 122°F (-20 to 50°C) |
| Dimensions | Ø0.79 x 2.3" (Ø20 x 59 mm) |
| Housing Material | Stainless steel, PEEK plastic |
| Protection Class | IP68 |
| Battery Type | 1/2 AA lithium |
| Battery Service Life | 750 operating hours (measuring cycle 10 seconds at 250°F (121°C)) |
| Authorizations | CE |
Click on a category to view a selection of compatible accessories with the Testo 191-T2 HACCP Temperature Data Logger with rigid probe, 115 mm.