Work with clear visibility of your measurement results with this reliable meter that features a 4" (101.6 mm) LCD and an input bandwidth of 45 Hz to 6 kHz. Make convenient and accurate power measurements with this meter that features 19 power measurement parameters. In addition, this meter has two numerical display modes.
Work with clear visibility of your measurement results with this reliable meter that features a 4" (101.6 mm) LCD and an input bandwidth of 45 Hz to 6 kHz. Make convenient and accurate power measurements with this meter that features 19 power measurement parameters. In addition, this meter has two numerical display modes.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Measure the power consumption of products and standby power consumption of low-power devices with this meter. In addition, this power meter provides RS-232C, USB device (virtual COM), and LAN communication interfaces for remote control applications.
Features
Dual display modes
This digital power meter provides two display modes for various measuring situations. Standard mode displays eight measurement parameters (two major measurements + six secondary measurements) and related measurement setting parameters which is ideal for applications in R&D, design, and engineering verification. Simple mode displays four measurement parameters which can be useful in production environments.
Various measurement parameters
This digital power meter provides various measurement functions such as voltage, current, frequency, active power, apparent power, reactive power, power factor, crest factor, and total harmonic distortion measurement.
This power meter is also equipped to measure time integral of power or current for the DUT. Users can set a time window to perform instantaneous power integration at specified intervals and then divide value by total time period to obtain the average power of the DUT.
Optimal measurement capabilities
This digital power meter offers measurement frequency bandwidth of DC-6 kHz, minimum current level of 5 mA (resolution: 0.1 μA), power measurement resolution of 1 μW(1 μW for minimum current and voltage levels; 1 mW for maximum current and voltage levels). These parameters meet the test requirement according to IEC 62301/EN 50564 standard and hence can be used to measure standby power consumption of low power devices.
This power meter offers PT/CT rate functions for large voltage/current measurement applications. High voltage measurements can be done using VT rate setting along with an external voltage Potential Transformer. Current measurements above 20 A can be done by connecting current transformer (current output type) directly to current input terminal on the rear panel and setting the appropriate CT ratio state in the ratio configuration menu.
Applications
Input | |
Rating | Voltage: 600 Vrms Current: 20 Arms |
Impedance (50/60 Hz) | Voltage: 2.4 MΩ Current: 5 to 200 mA: 500 mω and 0.5 to 20 A: 5 mΩ |
Maximum | Voltage: 700 Vrms Current: 25 Arms Common-mode voltage: 300 V |
Low Pass Filter | Cut off frequency: 500 Hz |
Parameters | |
Measurement | Voltage: VDC, Vrms, V+pk, V-pk Current: Idc, Irms, I+pk, I-pk Power: P, P+pk, P-pk, VA, VAR Crest factor: CFV, CFI Power factor: PF Frequency: VHz, Ihz Angle: DEG Total harmonic distorsion: THDV, THDI Integration: Time, WP, WP+, WP-, q, q+, q |
Display Digits | 5 digits |
Frequency Bandwidth | DC, 45 Hz to 6 kHz |
Average | 1, 2, 4, 8, 16, 32, 64 |
Rate | PT and CT: 1 to 999.999 |
Display Mode | Standard: Eight measurement items Simple: Four measurement items |
Voltage | |
Range | CF = 3: 15, 30, 60 , 150 , 300 , and 600 V CF = 6: 7.5, 15, 30, 75, 150, and 300 V |
Crest Factor | 3 or 6 (selectable) |
Accuracy | Effective range: 1 to 105 % of range DC: ±(0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ±(0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ±(0.1 % of reading + 0.2 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 0.3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Residual Noise | 0.5 % of range |
Current | |
Measurement | CF = 3: 5, 10, 20, 50, 100, 200, and 500 mA/1, 2, 5, 10, and 20 A CF = 6: 2.5, 5, 10, 25, 50, 100, and 250 mA/0.5, 1, 2.5, 5, and 10 A |
Crest Factor | 3 or 6 (selectable) |
Accuracy | Effective range: 1 to 105 % of range DC: ± (0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ± ;(0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ± (0.1 % of reading + 0.2 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 0.3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Residual Noise | 0.5 % of range |
Power | |
Accuracy | Effective range: 1 to 110 % of range DC: ± (0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ± (0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ± (0.1 % of reading + 0.3 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Frequency | |
Measurement | Filter (0n): 30 ~ 499.99 Hz Filter (Off): 30 ~ 9.9999 Hz |
Parameter | Voltage, current |
Effective Range | 10 ~ 105 % of voltage input |
Accuracy | ±0.06 % of reading |
Integration | |
Time | Accuracy: ± (voltage or current accuracy + 0.1 % of reading) Range: 0 hours 0 minuntes ~ 9999 hours 59 minutes Accuracy: ±0.01 % ±1 second |
General Specifications | |
Display | 4" (101.6 mm) TFT LCD |
Standard Interface | RS-232C,USB device, LAN |
Power | Source: AC 100 ~ 240 V, 50 to 60 Hz Consumption: Maximum 25 VA |
Dimensions | 10.63 x 4.33 x 13.78" (270 x110 x 350 mm) |
Weight | 6.39 lbs (2.9 kg) |
Input | |
Rating | Voltage: 600 Vrms Current: 20 Arms |
Impedance (50/60 Hz) | Voltage: 2.4 MΩ Current: 5 to 200 mA: 500 mω and 0.5 to 20 A: 5 mΩ |
Maximum | Voltage: 700 Vrms Current: 25 Arms Common-mode voltage: 300 V |
Low Pass Filter | Cut off frequency: 500 Hz |
Parameters | |
Measurement | Voltage: VDC, Vrms, V+pk, V-pk Current: Idc, Irms, I+pk, I-pk Power: P, P+pk, P-pk, VA, VAR Crest factor: CFV, CFI Power factor: PF Frequency: VHz, Ihz Angle: DEG Total harmonic distorsion: THDV, THDI Integration: Time, WP, WP+, WP-, q, q+, q |
Display Digits | 5 digits |
Frequency Bandwidth | DC, 45 Hz to 6 kHz |
Average | 1, 2, 4, 8, 16, 32, 64 |
Rate | PT and CT: 1 to 999.999 |
Display Mode | Standard: Eight measurement items Simple: Four measurement items |
Voltage | |
Range | CF = 3: 15, 30, 60 , 150 , 300 , and 600 V CF = 6: 7.5, 15, 30, 75, 150, and 300 V |
Crest Factor | 3 or 6 (selectable) |
Accuracy | Effective range: 1 to 105 % of range DC: ±(0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ±(0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ±(0.1 % of reading + 0.2 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 0.3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Residual Noise | 0.5 % of range |
Current | |
Measurement | CF = 3: 5, 10, 20, 50, 100, 200, and 500 mA/1, 2, 5, 10, and 20 A CF = 6: 2.5, 5, 10, 25, 50, 100, and 250 mA/0.5, 1, 2.5, 5, and 10 A |
Crest Factor | 3 or 6 (selectable) |
Accuracy | Effective range: 1 to 105 % of range DC: ± (0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ± ;(0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ± (0.1 % of reading + 0.2 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 0.3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Residual Noise | 0.5 % of range |
Power | |
Accuracy | Effective range: 1 to 110 % of range DC: ± (0.2 % of reading + 0.2 % of range) 45 Hz ≤ f ≤66 Hz: ± (0.1 % of reading + 0.1 % of range) 66 Hz < f ≤1 kHz: ± (0.1 % of reading + 0.3 % of range) 1 kHz < f ≤6 kHz: ±3 % of reading Filter (On): Add 3 % of reading at 45 ~ 66 Hz |
Temperature Effect | 5 to 18°C/28 to 40°C: Add ±0.03 % of reading/°C |
Frequency | |
Measurement | Filter (0n): 30 ~ 499.99 Hz Filter (Off): 30 ~ 9.9999 Hz |
Parameter | Voltage, current |
Effective Range | 10 ~ 105 % of voltage input |
Accuracy | ±0.06 % of reading |
Integration | |
Time | Accuracy: ± (voltage or current accuracy + 0.1 % of reading) Range: 0 hours 0 minuntes ~ 9999 hours 59 minutes Accuracy: ±0.01 % ±1 second |
General Specifications | |
Display | 4" (101.6 mm) TFT LCD |
Standard Interface | RS-232C,USB device, LAN |
Power | Source: AC 100 ~ 240 V, 50 to 60 Hz Consumption: Maximum 25 VA |
Dimensions | 10.63 x 4.33 x 13.78" (270 x110 x 350 mm) |
Weight | 6.39 lbs (2.9 kg) |