Capable of probing up to 1000 Vrms, this high voltage passive probe can handle 6000 V peak transients and features a spring-loaded probe tip that makes probing high voltages safe and easy. In addition, this probe has a fast rise time and excellent frequency.
Capable of probing up to 1000 Vrms, this high voltage passive probe can handle 6000 V peak transients and features a spring-loaded probe tip that makes probing high voltages safe and easy. In addition, this probe has a fast rise time and excellent frequency.
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. In addition, this probe has a sense pin to automatically configure the oscilloscope for use with the probe.
Features
Electrical Characteristics | |
Bandwidth | 400 MHz |
Risetime (10 to 90%) | 900 ps (typical) |
Maximum Input Voltage | Measurement Category II: 1000 Vrms Measurement Category I: 4000 V transient overvoltage at 1000 Vrms/6000 V transient overvoltage at 0 Vrms |
Pollution Degree | 2° |
Input Capacitance | 7.5 pF (typical) |
Compensation Range | 10 to 50 pF (typical) |
Attenuation Ratio | 100:1 ±2% |
Environmental | |
Temperature | Operating: 32 to 122°F (0 to 50°C) Non-operating: -40 to 160°F (-40 to 71°C) |
Operating Humidity | 80% RH (non-condensing) up to 87.8°F (31°C) Decreasing linearly to 40% RH at 122°F (50°C) |
Altitude | Operating: up to approximately 6562' (2000 m) Non-operating: up to approximately 49,213' (15,000 m) |
General Characteristics | |
Cable Length | 6.56' (2 m) |
Probe Tip Diameter | 0.20" (5 mm) |
Weight (Probe) | 0.15 lbs (67 g) |
Electrical Characteristics | |
Bandwidth | 400 MHz |
Risetime (10 to 90%) | 900 ps (typical) |
Maximum Input Voltage | Measurement Category II: 1000 Vrms Measurement Category I: 4000 V transient overvoltage at 1000 Vrms/6000 V transient overvoltage at 0 Vrms |
Pollution Degree | 2° |
Input Capacitance | 7.5 pF (typical) |
Compensation Range | 10 to 50 pF (typical) |
Attenuation Ratio | 100:1 ±2% |
Environmental | |
Temperature | Operating: 32 to 122°F (0 to 50°C) Non-operating: -40 to 160°F (-40 to 71°C) |
Operating Humidity | 80% RH (non-condensing) up to 87.8°F (31°C) Decreasing linearly to 40% RH at 122°F (50°C) |
Altitude | Operating: up to approximately 6562' (2000 m) Non-operating: up to approximately 49,213' (15,000 m) |
General Characteristics | |
Cable Length | 6.56' (2 m) |
Probe Tip Diameter | 0.20" (5 mm) |
Weight (Probe) | 0.15 lbs (67 g) |