Work with the highest accuracy, best signal fidelity, and comprehensive connectivity with this high-voltage optically isolated probe that features a 1 GHz bandwidth. In addition, this probe is suitable for many applications and enables the highest confidence in GaN and SiC device characterization.
Work with the highest accuracy, best signal fidelity, and comprehensive connectivity with this high-voltage optically isolated probe that features a 1 GHz bandwidth. In addition, this probe is suitable for many applications and enables the highest confidence in GaN and SiC device characterization.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
Best signal fidelity
During measurements, getting the most faithful representation of the signal can be elusive. This probe overcomes that challenge by delivering the industry's best signal delity with the fastest rise time, lowest overshoot, and low DUT loading
Comprehensive connectivity
This probe increases measurement confidence by employing high-quality coaxial attenuating tips that reject unwanted noise and terminate into test boards using industry standard MMCX connectors or high-voltage safe square pin headers.
Flexible in-circuit debug
Applications
Electrical | |
Bandwidth | 1 GHz |
Rise Time (10 to 90%) | 435 ps |
Differential Voltage Range (Pk to Pk) | 2 to 2500 V with different attenuating tips |
Common Mode Voltage Range | ±60 kV (DC+Peak AC), not for handheld use, with adequate spacing between probe components and eart ground |
Maximum Input Voltage to Earth | ±60 kV (DC+Peak AC), not for hand-held use, with adequate spacing between probe components and earth ground |
DC Gain | Accuracy: 1.5% (after Precision Gain Calibration) Drift: <1%/°C |
Output Termination | 50Ω |
Input/Output Coupling | DC only |
Interface | ProBus |
Cable Length | 11' (3.375 m) from probe tip to oscilloscope connection |
Noise, rejection, and electromagnetic compatibility (EMC) | |
Electrostatic Discharge (ESD) Immunity | 8 kV contact discharge and 10 kV air discharge per IEC61000-4-2, criteria A |
Radiated RF Electromagnetic Field Immunity | Up to 25 V/m (80 MHz to 2.7 GHz) per IEC61000-4-3, criteria A when operating in standard con guration |
Immunity to Conducted Disturbance Induced by RF Fields | Up to 10 V (150 kHz to 80 MHz) per IEC61000-4-6, criteria A when operating in standard con guration |
General Specifications | |
Temperature | Operating in standard configuration: 41 to 104°F (5 to 40°C) Non-operating: -4 to 158°F (-20 to 70°C) |
Humidity | 5 to 95% RH (non-condensing), 75% RH above 86°F (30°C), 45% RH above 104°F (40°C) |
Altitude | Operating: Up to 9842.52' (3000 m) Non-operating: Up to 32808.4' (10,000 m) |
Pollution Degree | 2, indoor use only |
CE Declaration of Conformity | Low Voltage Directive 2014/35/EU (IEC/EN 61010-1:2010; IEC/EN 61010-2-030:2010) EMC Directive 2014/30/EU (IEC/EN 61326-1:2013; IEC/EN 61326-2-1:2013) RoHS2 Directive 2011/65/EU (IEC/EN 63000:2018) |
Laser Product Certifications | IEC/EN 60825-1:2014; US 21CFR Part 1010; US 21CFR Part 1040 |
Electrical | |
Bandwidth | 1 GHz |
Rise Time (10 to 90%) | 435 ps |
Differential Voltage Range (Pk to Pk) | 2 to 2500 V with different attenuating tips |
Common Mode Voltage Range | ±60 kV (DC+Peak AC), not for handheld use, with adequate spacing between probe components and eart ground |
Maximum Input Voltage to Earth | ±60 kV (DC+Peak AC), not for hand-held use, with adequate spacing between probe components and earth ground |
DC Gain | Accuracy: 1.5% (after Precision Gain Calibration) Drift: <1%/°C |
Output Termination | 50Ω |
Input/Output Coupling | DC only |
Interface | ProBus |
Cable Length | 11' (3.375 m) from probe tip to oscilloscope connection |
Noise, rejection, and electromagnetic compatibility (EMC) | |
Electrostatic Discharge (ESD) Immunity | 8 kV contact discharge and 10 kV air discharge per IEC61000-4-2, criteria A |
Radiated RF Electromagnetic Field Immunity | Up to 25 V/m (80 MHz to 2.7 GHz) per IEC61000-4-3, criteria A when operating in standard con guration |
Immunity to Conducted Disturbance Induced by RF Fields | Up to 10 V (150 kHz to 80 MHz) per IEC61000-4-6, criteria A when operating in standard con guration |
General Specifications | |
Temperature | Operating in standard configuration: 41 to 104°F (5 to 40°C) Non-operating: -4 to 158°F (-20 to 70°C) |
Humidity | 5 to 95% RH (non-condensing), 75% RH above 86°F (30°C), 45% RH above 104°F (40°C) |
Altitude | Operating: Up to 9842.52' (3000 m) Non-operating: Up to 32808.4' (10,000 m) |
Pollution Degree | 2, indoor use only |
CE Declaration of Conformity | Low Voltage Directive 2014/35/EU (IEC/EN 61010-1:2010; IEC/EN 61010-2-030:2010) EMC Directive 2014/30/EU (IEC/EN 61326-1:2013; IEC/EN 61326-2-1:2013) RoHS2 Directive 2011/65/EU (IEC/EN 63000:2018) |
Laser Product Certifications | IEC/EN 60825-1:2014; US 21CFR Part 1010; US 21CFR Part 1040 |