Teledyne LeCroy AP031 700V, 25 MHz High Voltage Differential Probe

Model: AP031

Teledyne LeCroy AP031 700V, 25 MHz High Voltage Differential Probe

Model: AP031

The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.

The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Test Probes category for similar products.

Or let's do a search and help you find what you need:


Teledyne LeCroy AP031 Offers

This probe is specifically designed for situations where:

  • The reference voltage may be several hundreds volts above or below ground
  • Measurements require the rejection of common mode signals
  • Ground loops and currents produce to excessive signal interference
  • The use of the probe ensures safe operation of the oscilloscope and maintains high signal fidelity with good common mode rejection and dynamic range

Teledyne LeCroy AP031 Specifications

Bandwidth 25 MHz
Rise Time 14 ns
Attenuation 1:10/1:100
Attenuation Accuracy ±2 %
Input Resistance 4 Mω
Input Capacitance 5.5 pF each side to ground
Input Configuration Differential
Input Voltage Maximum Differential 1:100 Range: ±700 V (DC + AC pk) and 700 V rms
Maximum Differential 1:10 Range: ±70 V (DC + AC pk) and 70 V rms
Maximum Common Mode: ±700 V (DC + AC pk) and 700 V rms
Maximum Absolute: ±1400 V ( DC + AC pk) and 1000 V rms
CMRR 50 Hz to 80 dB; 20 kHz to 60 dB
Typical Output Offset <±5 mV
Typical Output Noise 0.7 mV rms typical
Maximum Input Voltage 1000 V rms (1400 V DC + peak AC)
Installation (Overvoltage) Category III
Pollution Degree 2
Cable Length 1.3 m
Weight (probe only) 42 g
Click here for complete specifications on the Teledyne LeCroy AP031

What's included with the Teledyne LeCroy AP031

  • High-Voltage Differential Probe
  • 2 x 4 mm Compatible Safety Hooks (1 Red, 1 Black)

Teledyne LeCroy AP031 Offers

This probe is specifically designed for situations where:

  • The reference voltage may be several hundreds volts above or below ground
  • Measurements require the rejection of common mode signals
  • Ground loops and currents produce to excessive signal interference
  • The use of the probe ensures safe operation of the oscilloscope and maintains high signal fidelity with good common mode rejection and dynamic range

Teledyne LeCroy AP031 Specifications

Bandwidth 25 MHz
Rise Time 14 ns
Attenuation 1:10/1:100
Attenuation Accuracy ±2 %
Input Resistance 4 Mω
Input Capacitance 5.5 pF each side to ground
Input Configuration Differential
Input Voltage Maximum Differential 1:100 Range: ±700 V (DC + AC pk) and 700 V rms
Maximum Differential 1:10 Range: ±70 V (DC + AC pk) and 70 V rms
Maximum Common Mode: ±700 V (DC + AC pk) and 700 V rms
Maximum Absolute: ±1400 V ( DC + AC pk) and 1000 V rms
CMRR 50 Hz to 80 dB; 20 kHz to 60 dB
Typical Output Offset <±5 mV
Typical Output Noise 0.7 mV rms typical
Maximum Input Voltage 1000 V rms (1400 V DC + peak AC)
Installation (Overvoltage) Category III
Pollution Degree 2
Cable Length 1.3 m
Weight (probe only) 42 g
Click here for complete specifications on the Teledyne LeCroy AP031