This economical data logger is designed for measuring external voltage and current in single-phase systems. It allows easy exporting of data to Excel or text files and can be combined with other units for three-phase measurements.
This economical data logger is designed for measuring external voltage and current in single-phase systems. It allows easy exporting of data to Excel or text files and can be combined with other units for three-phase measurements.
Features
Applications
| Sample Point Capacity | 10,750 points for Current & Voltage 21,500 points for Current OR Voltage |
| Sampling Rate | 1 second to 18 hours |
| Alarms | Over and under alarms for current and voltage |
| Time Accuracy | ±100 ppm @75°F (23.9°C) |
| Input Current Range | 0 to 300 Amps |
| Current Accuracy | ±5% |
| Current Resolution | 0.1 Amp AC |
| Voltage Range | 0 to 500 Volts AC |
| Voltage Accuracy | ±1 V AC |
| Voltage Resolution | 0.1 V AC |
| Temperature Using Alkaline Battery | 32 to 140°F (0 to 60°C) |
| Temperature Using Lithium Battery | -40 to 150°F (-40 to 65°C) |
| Storage Temperature | -40 to 170°F (-40 to 77°C) |
| Operating Range Humidity | 0% to 95% RH Non-condensing |
| Calibration | Single point offset calibration available through software.Current and Voltage are factory calibrated |
| Dimensions | 3 x 2.5 x 1.1" (7.62 x 6.35 x 2.79 cm) |
| Weight | 2.5 oz (71 g) |
| Power Source | 9 V Alkaline or Lithium battery (not included) |
| Battery Life (average Use) | 20 Months using Alkaline Battery 40 Months using Lithium Battery |
| Sample Point Capacity | 10,750 points for Current & Voltage 21,500 points for Current OR Voltage |
| Sampling Rate | 1 second to 18 hours |
| Alarms | Over and under alarms for current and voltage |
| Time Accuracy | ±100 ppm @75°F (23.9°C) |
| Input Current Range | 0 to 300 Amps |
| Current Accuracy | ±5% |
| Current Resolution | 0.1 Amp AC |
| Voltage Range | 0 to 500 Volts AC |
| Voltage Accuracy | ±1 V AC |
| Voltage Resolution | 0.1 V AC |
| Temperature Using Alkaline Battery | 32 to 140°F (0 to 60°C) |
| Temperature Using Lithium Battery | -40 to 150°F (-40 to 65°C) |
| Storage Temperature | -40 to 170°F (-40 to 77°C) |
| Operating Range Humidity | 0% to 95% RH Non-condensing |
| Calibration | Single point offset calibration available through software.Current and Voltage are factory calibrated |
| Dimensions | 3 x 2.5 x 1.1" (7.62 x 6.35 x 2.79 cm) |
| Weight | 2.5 oz (71 g) |
| Power Source | 9 V Alkaline or Lithium battery (not included) |
| Battery Life (average Use) | 20 Months using Alkaline Battery 40 Months using Lithium Battery |