Schneider Electric METSEEM3555 PowerLogic™ DIN Rail Meter, 5 to 32,000 A, modbus 4 quadrant

Model: METSEEM3555

Schneider Electric METSEEM3555 PowerLogic™ DIN Rail Meter, 5 to 32,000 A, modbus 4 quadrant

Model: METSEEM3555

A three-phase DIN rail energy meter designed for precise sub-metering and cost allocation. It supports low-voltage CTs with 1/3 V or 1 V output, measures 5 to 32,000 A, and features Modbus communication with 4-quadrant metering capability.

A three-phase DIN rail energy meter designed for precise sub-metering and cost allocation. It supports low-voltage CTs with 1/3 V or 1 V output, measures 5 to 32,000 A, and features Modbus communication with 4-quadrant metering capability.

Sale Price $1500.00 USD
Regular Price $3248.46 USD
Availability 2 to 3 Weeks
Quantity

Schneider METSEEM3555 Offers

Features

  • Energy monitoring in building automation systems
  • Renewable energy and industrial monitoring
  • Ease of setup and integration
  • Billing flexibility
  • ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
  • 90 to 600 VAC; application versatility with fewer models to stock
  • Bright backlit LCD; easy visibility in dark enclosures
  • Compatible with LVCTs from 5 to 32000 A; wide range of service types
  • User-enabled password protection; prevents tampering

Applications

  • Energy monitoring in building automation systems
  • Renewable energy monitoring
  • Commercial sub-metering
  • Energy management
  • Industrial monitoring
  • Accurate cost allocation

Schneider METSEEM3555 Specifications

Range PowerLogic
Product or Component Type Energy meter
Metering Type Peak demand power PM, QM, SM
Demand power P, Q, S
Voltage U21, U32, U13, V1, V2, V3
Current I1, I2, I3, Iavg
Active, reactive, apparent energy (signed, four quadrant)
Poles Description 3P + N
Type Of Measurement Active and reactive power total
Active and reactive power per phase
Apparent power total
Apparent power per phase
Power factor total
Power factor per phase
Peak demand power
Current
Voltage
Frequency
Device Application Sub billing
Partial meter
Accuracy Class Class 0.2S power IEC 62053-22
Class 0.2S energy IEC 62053-22
Class 0.2S power ANSI C12.20
Class 0.2S energy ANSI C12.20
Measurement Accuracy Power ± 0.2%
Energy ± 0.2%
Input Type Low voltage current transformer 0.333 V or 1 V
Rated Voltage 90 to 347 V
Network Frequency 50 Hz
60 Hz
Technology Type Electronic
Display Type Backlit LCD
Measurement Current 5 to 32000 A
Display Digits 5
Information Displayed Status and alert
Communication with system
Input/output status
Error
Tx activity
Rx activity
Instant power per usage
Tamperproof of Settings Protected by access code
Communication Port Protocol Modbus RTU 1200 to 38400 bps - 2-wire
Communication Port Support Screw terminal block RS485
Communication of Data Instantaneous and demand values
Lifetime energy production
Communication Service Total cumulated energy
Total cumulated active energy
Data Recording Energy consumption logs
Demand Intervals External synchronisation to communication
Fixed or rolling block
Local Signalling Red LED threshold reached
Green flashing LED output signal
Number of Outputs 1 alarm output
1 pulse
Buffer Size 16-bit 10
Rated Operational Voltage 90 to 347 VAC 50/60 Hz between phase and neutral UL
156 to 600 V AC 50/60 Hz between phases UL
90 to 300 V AC 50/60 Hz between phase and neutral CE
125 to 300 V DC
Power Consumption in VA 5 VA 347 VAC between phase and neutral)
5 VA 600 VAC between phases)
Power Consumption in W 3 W 300 V
Ride-through Time 100 ms 120 VAC
Mounting Mode Clip-on
By screws
Mounting Support DIN rail
Standards IEC 61010-1
CSA C22.2 No 14-05
UL 508
Product Certifications CE conforming to IEC 61010
CULus conforming to UL 508
Relative Humidity 0 to 95 %
Ambient Air Temperature for Operation -22 to 158°F (-30 to 70°C)
Ambient Air Temperature for Storage -40 to 185°F (-40 to 85°C)
Colour Dark grey
0.35" (9 mm) Pitches 12
Dimensions 2.3 x 4.2 x 3.6" (59 x 107 x 91 mm)
Click here for complete specifications on the Schneider METSEEM3555

What's included with the Schneider METSEEM3555

  • Schneider Electric METSEEM3555 PowerLogic™ DIN Rail Meter, 5 to 32,000 A, modbus 4 quadrant

Schneider METSEEM3555 Offers

Features

  • Energy monitoring in building automation systems
  • Renewable energy and industrial monitoring
  • Ease of setup and integration
  • Billing flexibility
  • ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
  • 90 to 600 VAC; application versatility with fewer models to stock
  • Bright backlit LCD; easy visibility in dark enclosures
  • Compatible with LVCTs from 5 to 32000 A; wide range of service types
  • User-enabled password protection; prevents tampering

Applications

  • Energy monitoring in building automation systems
  • Renewable energy monitoring
  • Commercial sub-metering
  • Energy management
  • Industrial monitoring
  • Accurate cost allocation

Schneider METSEEM3555 Specifications

Range PowerLogic
Product or Component Type Energy meter
Metering Type Peak demand power PM, QM, SM
Demand power P, Q, S
Voltage U21, U32, U13, V1, V2, V3
Current I1, I2, I3, Iavg
Active, reactive, apparent energy (signed, four quadrant)
Poles Description 3P + N
Type Of Measurement Active and reactive power total
Active and reactive power per phase
Apparent power total
Apparent power per phase
Power factor total
Power factor per phase
Peak demand power
Current
Voltage
Frequency
Device Application Sub billing
Partial meter
Accuracy Class Class 0.2S power IEC 62053-22
Class 0.2S energy IEC 62053-22
Class 0.2S power ANSI C12.20
Class 0.2S energy ANSI C12.20
Measurement Accuracy Power ± 0.2%
Energy ± 0.2%
Input Type Low voltage current transformer 0.333 V or 1 V
Rated Voltage 90 to 347 V
Network Frequency 50 Hz
60 Hz
Technology Type Electronic
Display Type Backlit LCD
Measurement Current 5 to 32000 A
Display Digits 5
Information Displayed Status and alert
Communication with system
Input/output status
Error
Tx activity
Rx activity
Instant power per usage
Tamperproof of Settings Protected by access code
Communication Port Protocol Modbus RTU 1200 to 38400 bps - 2-wire
Communication Port Support Screw terminal block RS485
Communication of Data Instantaneous and demand values
Lifetime energy production
Communication Service Total cumulated energy
Total cumulated active energy
Data Recording Energy consumption logs
Demand Intervals External synchronisation to communication
Fixed or rolling block
Local Signalling Red LED threshold reached
Green flashing LED output signal
Number of Outputs 1 alarm output
1 pulse
Buffer Size 16-bit 10
Rated Operational Voltage 90 to 347 VAC 50/60 Hz between phase and neutral UL
156 to 600 V AC 50/60 Hz between phases UL
90 to 300 V AC 50/60 Hz between phase and neutral CE
125 to 300 V DC
Power Consumption in VA 5 VA 347 VAC between phase and neutral)
5 VA 600 VAC between phases)
Power Consumption in W 3 W 300 V
Ride-through Time 100 ms 120 VAC
Mounting Mode Clip-on
By screws
Mounting Support DIN rail
Standards IEC 61010-1
CSA C22.2 No 14-05
UL 508
Product Certifications CE conforming to IEC 61010
CULus conforming to UL 508
Relative Humidity 0 to 95 %
Ambient Air Temperature for Operation -22 to 158°F (-30 to 70°C)
Ambient Air Temperature for Storage -40 to 185°F (-40 to 85°C)
Colour Dark grey
0.35" (9 mm) Pitches 12
Dimensions 2.3 x 4.2 x 3.6" (59 x 107 x 91 mm)
Click here for complete specifications on the Schneider METSEEM3555

What's included with the Schneider METSEEM3555

  • Schneider Electric METSEEM3555 PowerLogic™ DIN Rail Meter, 5 to 32,000 A, modbus 4 quadrant

More Schneider Products