The gas analyzer measures emissions of up to 9 different gases and calculates efficiency, excess air and CO₂%. The industrial unit also measures stack gas and air temperature and draft and differential pressure.
The gas analyzer measures emissions of up to 9 different gases and calculates efficiency, excess air and CO₂%. The industrial unit also measures stack gas and air temperature and draft and differential pressure.
The E Instruments E8500P-OCN-0-12 E8500 Plus Flue Gas and Emissions Analyzer is a portable tool for EPA compliance-level emissions monitoring that can be used in boiler, engine and combustion equipment applications. It has a built-in thermoelectric chiller that quickly removes water vapor from gas samples to prevent bubbling and an automatic condensate drain that pumps the accumulated water out. With real-time software and data logging capability, this gas analyzer lets you view data in the field when connected to a laptop via Bluetooth® or USB cable.
Features
Compatible Gas Type(s) | Multiple |
Gas Measurement Range | O₂: 0 to 25%; CO: 0 to 8,000 ppm; CO auto range: 0 to 20,000 ppm; CO (NDIR): 0 to 15%; CO₂ (NDIR): 0 to 50%; CO₂ (calculated): 0 to 99.9%; NO: 0 to 5,000 ppm; NO₂: 0 to 1,000 ppm; Low NO/NO₂: 0 to 100.0 ppm; NOx (calculated): 0 to 5,000 ppm; SO₂: 0 to 5,000 ppm; Low SO₂: 0 to 100.0 ppm; CxHy (HC): 0 to 3.00%; H₂S: 0 to 500 ppm; VOC: 0 to 200 ppm |
Gas Resolution | O₂: 0.1%; CO: 1 ppm; CO auto range: 1 ppm; CO (NDIR): 0.01%; CO₂ (NDIR): 0.1%; CO₂ (calculated): 0.1%; NO: 1 ppm; NO₂: 1 ppm; Low NO/NO₂: 0.1 ppm; NOx (calculated): 1 ppm; SO₂: 1 ppm; Low SO₂: 0.1 ppm; CxHy (HC): 0.01%; H₂S: 1 ppm; VOC: 1 ppm |
Gas Accuracy | O₂: ±0.1% vol; CO: ±8 ppm <300 ppm, ±4% rdg up to 2,000 ppm, ±10% rdg for >2,000 ppm; CO auto range: ±10% rdg; CO (NDIR): ±3% rdg; CO₂ (NDIR): ±3% rdg <20%, ±5% rdg >20%; NO: ±5 ppm <125 ppm, ±4% rdg for <5,000 ppm; NO₂: ±5 ppm <125 ppm, ±4% rdg for <1,000 ppm; Low NO/NO₂: ±1.5 ppm <50.0 ppm, ±4% rdg for <100.0 ppm; SO₂: ±5 ppm <125 ppm, ±4% rdg for <5000 ppm; Low SO₂: ±1.5 ppm <50.0 ppm, ±4% rdg for <100.0 ppm; CxHy (HC): ±3% rdg + 0.01%; H₂S: ±5 ppm <125 ppm, ±4% <500 ppm; VOC: ±10% rdg + 1 ppm |
Combustion Efficiency | 1 to 99.9% |
Pressure Measurement Range | ±40.0 inH₂O; ±100 mbar |
Pressure Resolution | 0.1 inH₂O |
Pressure Accuracy | ±1% rdg |
Internal Storage Capacity | 2,000 tests |
Power Source | Battery powered |
Battery Type | Battery pack |
Rechargeable Battery | Yes |
Product Length | 12" (300 mm) probe; 10' (3 m) probe hose |
Compatible Gas Type(s) | Multiple |
Gas Measurement Range | O₂: 0 to 25%; CO: 0 to 8,000 ppm; CO auto range: 0 to 20,000 ppm; CO (NDIR): 0 to 15%; CO₂ (NDIR): 0 to 50%; CO₂ (calculated): 0 to 99.9%; NO: 0 to 5,000 ppm; NO₂: 0 to 1,000 ppm; Low NO/NO₂: 0 to 100.0 ppm; NOx (calculated): 0 to 5,000 ppm; SO₂: 0 to 5,000 ppm; Low SO₂: 0 to 100.0 ppm; CxHy (HC): 0 to 3.00%; H₂S: 0 to 500 ppm; VOC: 0 to 200 ppm |
Gas Resolution | O₂: 0.1%; CO: 1 ppm; CO auto range: 1 ppm; CO (NDIR): 0.01%; CO₂ (NDIR): 0.1%; CO₂ (calculated): 0.1%; NO: 1 ppm; NO₂: 1 ppm; Low NO/NO₂: 0.1 ppm; NOx (calculated): 1 ppm; SO₂: 1 ppm; Low SO₂: 0.1 ppm; CxHy (HC): 0.01%; H₂S: 1 ppm; VOC: 1 ppm |
Gas Accuracy | O₂: ±0.1% vol; CO: ±8 ppm <300 ppm, ±4% rdg up to 2,000 ppm, ±10% rdg for >2,000 ppm; CO auto range: ±10% rdg; CO (NDIR): ±3% rdg; CO₂ (NDIR): ±3% rdg <20%, ±5% rdg >20%; NO: ±5 ppm <125 ppm, ±4% rdg for <5,000 ppm; NO₂: ±5 ppm <125 ppm, ±4% rdg for <1,000 ppm; Low NO/NO₂: ±1.5 ppm <50.0 ppm, ±4% rdg for <100.0 ppm; SO₂: ±5 ppm <125 ppm, ±4% rdg for <5000 ppm; Low SO₂: ±1.5 ppm <50.0 ppm, ±4% rdg for <100.0 ppm; CxHy (HC): ±3% rdg + 0.01%; H₂S: ±5 ppm <125 ppm, ±4% <500 ppm; VOC: ±10% rdg + 1 ppm |
Combustion Efficiency | 1 to 99.9% |
Pressure Measurement Range | ±40.0 inH₂O; ±100 mbar |
Pressure Resolution | 0.1 inH₂O |
Pressure Accuracy | ±1% rdg |
Internal Storage Capacity | 2,000 tests |
Power Source | Battery powered |
Battery Type | Battery pack |
Rechargeable Battery | Yes |
Product Length | 12" (300 mm) probe; 10' (3 m) probe hose |