Water and corrosion-resistant, this single-gas detector detects IR CO2, features a 0 to 50% volume range, and helps with your system maintenance needs. In addition, it performs single-person calibrations and remote sampling up to 5000' (1524 m) from a controller and interfaces to any RKI or third-party control systems.
Water and corrosion-resistant, this single-gas detector detects IR CO2, features a 0 to 50% volume range, and helps with your system maintenance needs. In addition, it performs single-person calibrations and remote sampling up to 5000' (1524 m) from a controller and interfaces to any RKI or third-party control systems.
Features
Applications
| Target Gas and Detection Range | Carbon Dioxide (CO2): 0 to 50% volume |
| Input Power | 24 V DC nominal (18.5 V DC to 30 V DC) |
| Sampling Method | Sample-draw |
| Sample Flow | 3.0 SCFH typical, with no inlet or exhaust line |
| Flow to Sensor | 1.0 SCFH (nominal) |
| Low Flow Setpoint | 0.6 ±0.1 SCFH |
| Response Time | 90% in 30 seconds |
| Accuracy | ±5% of reading or ±2% LEL (whichever is greater) |
| Construction (Housing) | Fibreglass/polyester (NEMA 4X) |
| Dimensions | 8.5 x 6.5 x 4.25" (215.9 x 165.1 x 107.9 mm) |
| Target Gas and Detection Range | Carbon Dioxide (CO2): 0 to 50% volume |
| Input Power | 24 V DC nominal (18.5 V DC to 30 V DC) |
| Sampling Method | Sample-draw |
| Sample Flow | 3.0 SCFH typical, with no inlet or exhaust line |
| Flow to Sensor | 1.0 SCFH (nominal) |
| Low Flow Setpoint | 0.6 ±0.1 SCFH |
| Response Time | 90% in 30 seconds |
| Accuracy | ±5% of reading or ±2% LEL (whichever is greater) |
| Construction (Housing) | Fibreglass/polyester (NEMA 4X) |
| Dimensions | 8.5 x 6.5 x 4.25" (215.9 x 165.1 x 107.9 mm) |