Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

Model: RAYGPC | UPC: 095969313964

Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

Model: RAYGPC | UPC: 095969313964

1/8 DIN digital panel meter provides a compact, easy-to-use interface and display for process instruments that can be used with many Raytek noncontact, infrared temperature sensors.

1/8 DIN digital panel meter provides a compact, easy-to-use interface and display for process instruments that can be used with many Raytek noncontact, infrared temperature sensors.

Sale Price $799.37 USD
Regular Price $946.00 USD
Availability 4 in Stock
Quantity

Raytek RAYGPC Offers

Features

  • Accepts any 0–5 V or 4–20 mA sensor input
  • Accepts type J, K, E, N, R, S, and T thermocouple inputs
  • 5V alarm outputs
  • Compact 1/8 DIN monitor
  • Large 4-digit LED display
  • Universal 110/220 VAC power
  • Provides 24 VDC/50 mA excitation voltage
  • User defined 4–20 mA or thermocouple output (J, K, E, N, R, S, T)
  • Adjustable dual setpoints and deadband controlling alarm outputs
  • Advanced signal processing capabilites including Peak and Valley Hold, Averaging and User adjustable offset
  • External reset input

Raytek RAYGPC Specifications

Resolution 0–5V Input: 1 mV; 4–20 mA Input: 0.01 mA; 4–20 mA Output: 0.014 mA
Accuracy (mV) 0–5V Input: ±2 mV; 4–20 mA Input/Output: ±0.02 mA
Accuracy (t/c) J, K, E, N, T Input/Output: ±0.05% or ±2°C, whichever is greater; R, S Input: ±0.5% or ±3°C, whichever is greater; R, S Output: ±0.5% or ±4°C, whichever is greater;
System Repeatability 500 mSec
Response Time (95%) ± 0.5% of reading or ± 2°C, whichever is greater
Signal Processing Peak Hold, Valley Hold (up to 998 sec, 999=infinite hold with external reset), Variable averaging filter (up to 60 seconds)
Inputs User-configurable, 0–5 V or 4–20 mA or J, K, E, N, R, S, T thermocouple. External reset input to reset Peak/Valley Hold circuit.
Outputs 4-digit, 7-segment LED display; °C/°F selectable; User-configurable 4–20 mA current or thermocouple output (J, K, E, N, R, S, T). Two adjustable setpoints with deadbands controlling 5V alarm outputs; 24VDC/50 mA excitation voltage for powering external sensor
Power Supply 110/220 VAC, ±20%, 50/60 Hz

 

Click here for complete specifications on the Raytek RAYGPC

What's included with the Raytek RAYGPC

  • Digital panel meter
  • Panel mounting hardware

Click on a category to view a selection of compatible accessories with the Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC.

Raytek XXXCB25W High Temperature 7 Conductor Cable for Raytek GPRC Models, 7.7m (25 ft) XXXCB25W
Features a 7-pin DIN connector. For use with coolable housing.








Raytek XXXCB50W High Temperature 7 Conductor Cable for Raytek GPRC Models, 15m (50 ft) XXXCB50W
Features a 7-pin DIN connector. For use with coolable housing.





Raytek XXXGPSSRAC Solid State Relay for 5VDC Alarm Outputs for Raytek GPC Models, 10A/24-330VAC XXXGPSSRAC
A solid state relay is a switching output for setpoint use as a control for an alarm or triggering mechanism. The setpoint output can supply 15mA at 5V for SSR control. Two relays are necessary to take advantage of both setpoints.




Raytek RAYGPC Offers

Features

  • Accepts any 0–5 V or 4–20 mA sensor input
  • Accepts type J, K, E, N, R, S, and T thermocouple inputs
  • 5V alarm outputs
  • Compact 1/8 DIN monitor
  • Large 4-digit LED display
  • Universal 110/220 VAC power
  • Provides 24 VDC/50 mA excitation voltage
  • User defined 4–20 mA or thermocouple output (J, K, E, N, R, S, T)
  • Adjustable dual setpoints and deadband controlling alarm outputs
  • Advanced signal processing capabilites including Peak and Valley Hold, Averaging and User adjustable offset
  • External reset input

Raytek RAYGPC Specifications

Resolution 0–5V Input: 1 mV; 4–20 mA Input: 0.01 mA; 4–20 mA Output: 0.014 mA
Accuracy (mV) 0–5V Input: ±2 mV; 4–20 mA Input/Output: ±0.02 mA
Accuracy (t/c) J, K, E, N, T Input/Output: ±0.05% or ±2°C, whichever is greater; R, S Input: ±0.5% or ±3°C, whichever is greater; R, S Output: ±0.5% or ±4°C, whichever is greater;
System Repeatability 500 mSec
Response Time (95%) ± 0.5% of reading or ± 2°C, whichever is greater
Signal Processing Peak Hold, Valley Hold (up to 998 sec, 999=infinite hold with external reset), Variable averaging filter (up to 60 seconds)
Inputs User-configurable, 0–5 V or 4–20 mA or J, K, E, N, R, S, T thermocouple. External reset input to reset Peak/Valley Hold circuit.
Outputs 4-digit, 7-segment LED display; °C/°F selectable; User-configurable 4–20 mA current or thermocouple output (J, K, E, N, R, S, T). Two adjustable setpoints with deadbands controlling 5V alarm outputs; 24VDC/50 mA excitation voltage for powering external sensor
Power Supply 110/220 VAC, ±20%, 50/60 Hz

 

Click here for complete specifications on the Raytek RAYGPC

What's included with the Raytek RAYGPC

  • Digital panel meter
  • Panel mounting hardware

Click on a category to view a selection of compatible accessories with the Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC.

Raytek XXXCB25W High Temperature 7 Conductor Cable for Raytek GPRC Models, 7.7m (25 ft) XXXCB25W
Features a 7-pin DIN connector. For use with coolable housing.








Raytek XXXCB50W High Temperature 7 Conductor Cable for Raytek GPRC Models, 15m (50 ft) XXXCB50W
Features a 7-pin DIN connector. For use with coolable housing.





Raytek XXXGPSSRAC Solid State Relay for 5VDC Alarm Outputs for Raytek GPC Models, 10A/24-330VAC XXXGPSSRAC
A solid state relay is a switching output for setpoint use as a control for an alarm or triggering mechanism. The setpoint output can supply 15mA at 5V for SSR control. Two relays are necessary to take advantage of both setpoints.




More Raytek Products