PSL PQube-02-0000 - PQube AC Power Monitor

Model: PQube-02-0000

PSL PQube-02-0000 - PQube AC Power Monitor

Model: PQube-02-0000

PQube AC Power Monitor. Precision power quality and quantity recorder. Basic accuracy ±0.05%. 4GB memory. 256 samples per cycle. 4 High Voltage AC inputs 2 Analog inputs 1 Digital Input 1 Relay Output.

PQube AC Power Monitor. Precision power quality and quantity recorder. Basic accuracy ±0.05%. 4GB memory. 256 samples per cycle. 4 High Voltage AC inputs 2 Analog inputs 1 Digital Input 1 Relay Output.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


PSL PQUBE-02-0000 690V 50/60Hz AC Power Monitor Offers

The PQube AC Power Monitor is a 690V, 50/60Hz power monitor for single- and three-phase systems. This power quality monitor records daily, weekly, and monthly trends, and It features time-triggered snapshots, impulse detection, and the frequency event monitoring. The PQube also provides waveforms and RMS graphs of voltage dips, swells, and interruptions and monitors THD, TDD, RMS Flicker, and voltage and current unbalance. The PQube features two analog inputs, two temperature/humidity monitoring channels, and up to 4 relay outputs. The PQube automatically saves data onto a standard SD card, so no software is required. The PQube includes one signal relay.


Applications

Industrial equipment

  • Size and price are perfect for embedding in automated machinery
  • Quickly pay for PQube with avoided service calls
  • Track energy trends over time - detect developing leaks, failing motors, and more

Medical

  • Perfect for embedding in MRI and CAT scanners.
  • Detect power quality events that cause intermittent errors, imaging malfunctions.
  • Provide energy monitoring: the first step in improving energy efficiency in medical facilities

Security scanning at airports

  • World-wide necessity - must function perfectly with bad power
  • Scanning errors can be catastrophic - embedded power quality monitoring is critical.

Power companies

  • Monitor key accounts at the meter, and at the critical loads: was it your problem, or a facility problem?
  • Lowest-cost system-wide monitoring - including PQDIF output files

Facility management companies

  • Add value with power quality and energy monitoring
  • PQube is the only monitoring system that doesn't require network infrastructure - just install and get useful data right away

Military bases, government campuses, large facilities

  • Allocate energy costs, and detect energy leaks
  • Full carbon monitoring for green initiatives
  • Start with no network; add e-mail later; then add full network support when needed

Data centers

  • AC and DC monitoring, plus temperature and humidity
  • Monitor input and output of power conditioning - demonstrate your improvements

Telecom

  • 3-phase and 1-phase AC monitoring, with simultaneous capture of disturbances on -48Vdc
  • Trigger on AC disturbances, -48Vdc disturbances, or both
  • Full daily, weekly, and monthly trends and statistics for proof of service

Researchers

  • All data stored in open-format files (Excel®-compatible CSV files)
  • Voltage, current, and DC oscilloscope waveforms, with sophisticated triggering
  • Daily, weekly, and monthly trends and statistics: voltage, current, frequency, power, temperature, humidity, and more

Green initiatives

  • Direct reading of carbon emissions, using patent-pending algorithms
  • Ultimate precision: 0.05% accuracy for sensitive energy savings measurements

Distributed generation - wind and solar

  • Ultra-precise 3-phase AC measurements, including net power flow
  • Ultra-precise frequency recording and disturbances for stability analysis
  • Detect LVRT (voltage dip) faults - speeds up acceptance tests and payment
  • Available 1500 Vdc and 600-amp DC sensors, simultaneous with built-in AC sensors, for inverter efficiency measurements, recording DC bus disturbances

Energy audits and Power Quality consulting

  • Direct graph outputs (GIF format) that copy/paste into your reports - no software required
  • Accumulated energy, peak energy, and daily/weekly/monthly trends and statistics for full understanding
  • The most accurate, most flexible, easiest-to-use power recorder ever made for energy and power quality

PSL PQUBE-02-0000 690V Specifications

Inputs - Mains Voltage Measuring Channels
ConnectionL1, L2, L3, N PQube screw terminals [9], [11], [13], [15]
Frequency Range40Hz~70Hz and 320Hz ~ 560Hz. Nominal 50Hz, 60Hz, or 400 Hz auto, 320-560Hz manually selected
Mains ConfigurationSingle-phase, delta, wye or star. User selected or auto-selected
Range of Nominal Input Voltage100VAC~690VAC L-L (69VAC~400VAC L-N) User selected or auto-selected
Measurement ChannelsLine-to-Neutral, Line-to-Line, Neutral-to-Earth
Sampling Rate256 samples per cycle, phase-locked to input frequency
Measurement range0 VAC ~ 900 VAC L-L (520 VAC L-N)
Accuracy±0.05% rdg ±0.05% FS typical (10% ~ 150% of nominal). Every PQube factory tested at better than ±0.04%rdg ±0.04%FS. Note: FS is based on measurement range.
RMS measurement methodTrue single-cycle RMS, phase-locked to each channel, updated every 1/2 cycle. URMS½ per IEC 61000-4-30 Class A. Also 10/12 cycle true-RMS per IEC 61000-4-30 Class A.
HF Impulse detectionL1-E, L2-E, L3-E. ±450Vpk nominal threshold detected through 2-pole high-pass 4.8 kHz nominal filter. Every PQube factory tested with 1-µsecond 10%-to-90% impulses; trigger required at ±650Vpk, must not trigger ±250Vpk.
Unbalance - voltageMeasurement method ANSI C84.1. Range: 0.0% - 100.0% Accuracy: ±0.1%.
THD - voltageMeasurement method: Discrete Fourier Transform of phase-locked 256-samples-per cycle. Range: 0.0% - 100.0% Accuracy: ±0.2% at test waveform having typical harmonic content (5% 5th, 2.5% 7th, 1.5% 9th, and 1% 11th). Samples measured through 6-pole low-pass analog anti-alias filter, 3 dB frequency 4.7 kHz.
RMS FlickerPinst - average absolute difference between URMS½ and 1-second RMS, in percent of nominal, multiplied by scaling factor for improved compatibility with Incandescent Flicker in IEC 61000-4-15. PST - mean value of Pinst over previous 10 minutes, synchronized to real-time clock. PLT - mean value of Pinst over previous 2 hours, synchronized to real-time clock. Range 0.0 ~ 20.0 . Accuracy ±0.1.
IsolationPQube provides more than 7500 VDC isolation to Earth. UL/IEC 61010 reinforced insulation.
PT Input Ratio Range1:1 to 10000:1
Installation categoryCAT IV UL/IEC 61010 for voltages up to 300VAC L-N (equivalent to 480VAC L-L), CAT III for higher voltages. Pollution Degree 2
Analog Input Channels
ConnectionAN1, AN2 PQube screw terminals [22], [30]
Nominal Input0~30VAC or ±60VDC (to Earth) max
Full Scale70VAC, ±100VDC
Measurement ChannelsAN1-Earth, AN2-Earth, AN1-AN2
User-specified Input Ratio1:1 to 10000:1
Sampling Rate12.8kHz or 15.4kHz (measured at same rate as mains voltage measuring channels)
Accuracy±0.2% rdg ±0.2% FS typical (10% ~ 100% FS). Every PQube factory tested at better than ±0.1% rdg ±0.1% FS AC.
Digital Input
ConnectionDIG1 PQube screw terminal [24]
Rating60VDC to Earth
Wetting5.4VDC at 3µA
Threshold1.5V±0.2V with respect to PQube's Earth terminal, with 0.3V hysteresis typical
Sampling Rate12.8kHz or 15.4kHz (sampled at same rate as mains voltage measuring channels)
Frequency Measurement
Range40Hz to 70Hz and 320Hz to 560Hz
Accuracy±0.01Hz, steady state
MethodCycle-by-cycle zero-crossing detection on L1-E or L2-E (auto-selected). Firmware phase-locked for frequency slew rate up to 5 Hz/sec. For 50/60 Hz, measured through an 9-pole low-pass analog filter, 3 dB frequency 76 Hz. For 400 Hz, measured through 7-pole low-pass filter, 3 dB frequency 1 kHz. Poles and 3 dB frequency are auto-selected based on nominal frequency.
Instrument Power
Screw Terminals(AC or DC) PQube POWER screw terminals [23], [31]
AC Input24VAC ± 20% 50/60 Hz
DC Input24-48VDC ± 20% (polarity independent)
Power Required5VA max
Internal UPS
TypeLithium Polymer Battery (replacement batteries available from PSL)
Capacity600mAH (30 minutes typical with new, fully-charged battery)
Backup periodUser controlled. 1 to 10 minutes, 3 minute default.
Optional PS1 Plug-in Module
AC Input100~240VAC ± 10%. 50/60 Hz
Power Required25VA max
IsolationModule provides more than 3200VDC isolation to all other circuits
Power measurements
Definitions
Watts (power)Sum of true instantaneous per-phase power
Volt-Amps (apparent power)Sum of per-phase product of RMS voltage and RMS current, taken over the measurement interval
Power Factor (tPF)True power factor - ratio of Watts to Volt-Amps.
VAR's (volt-amps reactive)Budeanu definition
Carbon (CO2 rate and accumulated)Based on patent-pending algorithm using watts and user-selected proportions of generator sources, and user-supplied carbon generation rates for each source.
Current unbalanceMeasurement method ANSI C84.1.
Accuracy excluding external CT's
Watts (power)±0.2% at unity power factor, nominal voltage, 20% ~ 100% FS current. Class 0.5 ANSI C12.20-1998. Better than ±0.25% rdg ±0.25% FS (10% ~ 120% FS), for phase angle Θfundamental = ±30° (angle between fundamental voltage and fundamental current). Accuracy calculation: sum of voltage accuracy, plus current accuracy, plus phase angle correction which is guaranteed less than ±0.025% x (1 / cos(Θfundamental)).
Volt-Amps (apparent power)Better than ±0.25% rdg ±0.25% FS typical (10% ~ 120% FS)
Measurement Interval Phase-locked, 10-cycles (50 Hz nominal) or 12-cycles (60 Hz nominal). Approximately 5 readings per second. Actual readings per second dependent on actual frequency.
Operating Environment
Ambient Conditions - Operating-20°C ~ 50°C, 10%~90% RH
Transient Voltages - 100kHz ring wave6 kV pk, IEC 61180, IEC 61000-4-5. Applied to voltage measuring terminals with Performance Evaluation Class 1. (When applied to optional power supply mains terminal, supply's fuse may operate in PE Class 3 at test levels greater than 4 kV.)
EFT Burst Immunity4 kV pk, IEC 61000-4-4, Performance Evaluation Class 1. Applied to power measuring terminals and optional PS1 power supply mains terminals
RF Field Strength Immunity3V / m, IEC 61000-4-3 Test Level 2
Magnetic Field Strength Immunity30A / m, IEC 61000-4-8 Test Level 4
Ingress Protection Rating (IP Rating)IP20H, IEC 60529
Agency Approvals and Listings
UL (Underwriters Laboratories)UL-recognized, cULus - File Number E220936
RoHSCertified - PSL Construction File PQube-001
CECertified - PSL Construction File PQube-001, TUV CB Test Certificate US-TUVR-4368-A2
EMCCertified - 20080102-01-CE, 20080326-01-RI
TUV Bauart-markCertified - TUV Report 30880881.009

Optional Current Measuring Modules

CT4
Measurement TypePass-through (built-in current transformers)
Accuracy±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.15% rdg ±0.15% FS.
Burdenless than 0.1VA
Conductors0.34 inches (8,6mm) max. diameter, 600V UL-recognized insulation required
XCT4
Measurement TypeExternal current transformer
CT input ratio range1:1 to 10000:1
Accuracy - excluding external CT's±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.15% rdg ±0.15% FS.
BurdenLess than 0.1VA
Wire connectionMin. 20AWG (0,52 mm2), Max. 14AWG (2.1mm2). 600V UL- recognized insulation required
XCT4-0.333V-00, XCT4-1V-00, XCT4-5V-00, and XCT4-10V-00
Measurement TypeExternal current transformer
CT input ratio range1:1 to 10000:1
Nominal0.333V RMS, 1V RMS, 5V RMS, and 10V RMS
Crest Factor3.5 (± 1.17V peak, 3.5V peak, 17.5V peak, and 35V peak)
Sampling Rate12.8kHz or 15.4kHz (measured at same rate as mains voltage measuring channels)
Accuracy - excluding external CT's±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.1% rdg ±0.1% FS.
Wire connectionMin. 20AWG (0,52 mm2), Max. 14AWG (2,1mm2). 600V UL- recognized insulation required
Max screw torque5 inch-pounds (0,6Nm)
Click here for complete specifications on the PSL PQube-02-0000

What's included with the PSL PQube-02-0000

  • PSL PQube-02-0000 - PQube AC Power Monitor

PSL PQUBE-02-0000 690V 50/60Hz AC Power Monitor Offers

The PQube AC Power Monitor is a 690V, 50/60Hz power monitor for single- and three-phase systems. This power quality monitor records daily, weekly, and monthly trends, and It features time-triggered snapshots, impulse detection, and the frequency event monitoring. The PQube also provides waveforms and RMS graphs of voltage dips, swells, and interruptions and monitors THD, TDD, RMS Flicker, and voltage and current unbalance. The PQube features two analog inputs, two temperature/humidity monitoring channels, and up to 4 relay outputs. The PQube automatically saves data onto a standard SD card, so no software is required. The PQube includes one signal relay.


Applications

Industrial equipment

  • Size and price are perfect for embedding in automated machinery
  • Quickly pay for PQube with avoided service calls
  • Track energy trends over time - detect developing leaks, failing motors, and more

Medical

  • Perfect for embedding in MRI and CAT scanners.
  • Detect power quality events that cause intermittent errors, imaging malfunctions.
  • Provide energy monitoring: the first step in improving energy efficiency in medical facilities

Security scanning at airports

  • World-wide necessity - must function perfectly with bad power
  • Scanning errors can be catastrophic - embedded power quality monitoring is critical.

Power companies

  • Monitor key accounts at the meter, and at the critical loads: was it your problem, or a facility problem?
  • Lowest-cost system-wide monitoring - including PQDIF output files

Facility management companies

  • Add value with power quality and energy monitoring
  • PQube is the only monitoring system that doesn't require network infrastructure - just install and get useful data right away

Military bases, government campuses, large facilities

  • Allocate energy costs, and detect energy leaks
  • Full carbon monitoring for green initiatives
  • Start with no network; add e-mail later; then add full network support when needed

Data centers

  • AC and DC monitoring, plus temperature and humidity
  • Monitor input and output of power conditioning - demonstrate your improvements

Telecom

  • 3-phase and 1-phase AC monitoring, with simultaneous capture of disturbances on -48Vdc
  • Trigger on AC disturbances, -48Vdc disturbances, or both
  • Full daily, weekly, and monthly trends and statistics for proof of service

Researchers

  • All data stored in open-format files (Excel®-compatible CSV files)
  • Voltage, current, and DC oscilloscope waveforms, with sophisticated triggering
  • Daily, weekly, and monthly trends and statistics: voltage, current, frequency, power, temperature, humidity, and more

Green initiatives

  • Direct reading of carbon emissions, using patent-pending algorithms
  • Ultimate precision: 0.05% accuracy for sensitive energy savings measurements

Distributed generation - wind and solar

  • Ultra-precise 3-phase AC measurements, including net power flow
  • Ultra-precise frequency recording and disturbances for stability analysis
  • Detect LVRT (voltage dip) faults - speeds up acceptance tests and payment
  • Available 1500 Vdc and 600-amp DC sensors, simultaneous with built-in AC sensors, for inverter efficiency measurements, recording DC bus disturbances

Energy audits and Power Quality consulting

  • Direct graph outputs (GIF format) that copy/paste into your reports - no software required
  • Accumulated energy, peak energy, and daily/weekly/monthly trends and statistics for full understanding
  • The most accurate, most flexible, easiest-to-use power recorder ever made for energy and power quality

PSL PQUBE-02-0000 690V Specifications

Inputs - Mains Voltage Measuring Channels
ConnectionL1, L2, L3, N PQube screw terminals [9], [11], [13], [15]
Frequency Range40Hz~70Hz and 320Hz ~ 560Hz. Nominal 50Hz, 60Hz, or 400 Hz auto, 320-560Hz manually selected
Mains ConfigurationSingle-phase, delta, wye or star. User selected or auto-selected
Range of Nominal Input Voltage100VAC~690VAC L-L (69VAC~400VAC L-N) User selected or auto-selected
Measurement ChannelsLine-to-Neutral, Line-to-Line, Neutral-to-Earth
Sampling Rate256 samples per cycle, phase-locked to input frequency
Measurement range0 VAC ~ 900 VAC L-L (520 VAC L-N)
Accuracy±0.05% rdg ±0.05% FS typical (10% ~ 150% of nominal). Every PQube factory tested at better than ±0.04%rdg ±0.04%FS. Note: FS is based on measurement range.
RMS measurement methodTrue single-cycle RMS, phase-locked to each channel, updated every 1/2 cycle. URMS½ per IEC 61000-4-30 Class A. Also 10/12 cycle true-RMS per IEC 61000-4-30 Class A.
HF Impulse detectionL1-E, L2-E, L3-E. ±450Vpk nominal threshold detected through 2-pole high-pass 4.8 kHz nominal filter. Every PQube factory tested with 1-µsecond 10%-to-90% impulses; trigger required at ±650Vpk, must not trigger ±250Vpk.
Unbalance - voltageMeasurement method ANSI C84.1. Range: 0.0% - 100.0% Accuracy: ±0.1%.
THD - voltageMeasurement method: Discrete Fourier Transform of phase-locked 256-samples-per cycle. Range: 0.0% - 100.0% Accuracy: ±0.2% at test waveform having typical harmonic content (5% 5th, 2.5% 7th, 1.5% 9th, and 1% 11th). Samples measured through 6-pole low-pass analog anti-alias filter, 3 dB frequency 4.7 kHz.
RMS FlickerPinst - average absolute difference between URMS½ and 1-second RMS, in percent of nominal, multiplied by scaling factor for improved compatibility with Incandescent Flicker in IEC 61000-4-15. PST - mean value of Pinst over previous 10 minutes, synchronized to real-time clock. PLT - mean value of Pinst over previous 2 hours, synchronized to real-time clock. Range 0.0 ~ 20.0 . Accuracy ±0.1.
IsolationPQube provides more than 7500 VDC isolation to Earth. UL/IEC 61010 reinforced insulation.
PT Input Ratio Range1:1 to 10000:1
Installation categoryCAT IV UL/IEC 61010 for voltages up to 300VAC L-N (equivalent to 480VAC L-L), CAT III for higher voltages. Pollution Degree 2
Analog Input Channels
ConnectionAN1, AN2 PQube screw terminals [22], [30]
Nominal Input0~30VAC or ±60VDC (to Earth) max
Full Scale70VAC, ±100VDC
Measurement ChannelsAN1-Earth, AN2-Earth, AN1-AN2
User-specified Input Ratio1:1 to 10000:1
Sampling Rate12.8kHz or 15.4kHz (measured at same rate as mains voltage measuring channels)
Accuracy±0.2% rdg ±0.2% FS typical (10% ~ 100% FS). Every PQube factory tested at better than ±0.1% rdg ±0.1% FS AC.
Digital Input
ConnectionDIG1 PQube screw terminal [24]
Rating60VDC to Earth
Wetting5.4VDC at 3µA
Threshold1.5V±0.2V with respect to PQube's Earth terminal, with 0.3V hysteresis typical
Sampling Rate12.8kHz or 15.4kHz (sampled at same rate as mains voltage measuring channels)
Frequency Measurement
Range40Hz to 70Hz and 320Hz to 560Hz
Accuracy±0.01Hz, steady state
MethodCycle-by-cycle zero-crossing detection on L1-E or L2-E (auto-selected). Firmware phase-locked for frequency slew rate up to 5 Hz/sec. For 50/60 Hz, measured through an 9-pole low-pass analog filter, 3 dB frequency 76 Hz. For 400 Hz, measured through 7-pole low-pass filter, 3 dB frequency 1 kHz. Poles and 3 dB frequency are auto-selected based on nominal frequency.
Instrument Power
Screw Terminals(AC or DC) PQube POWER screw terminals [23], [31]
AC Input24VAC ± 20% 50/60 Hz
DC Input24-48VDC ± 20% (polarity independent)
Power Required5VA max
Internal UPS
TypeLithium Polymer Battery (replacement batteries available from PSL)
Capacity600mAH (30 minutes typical with new, fully-charged battery)
Backup periodUser controlled. 1 to 10 minutes, 3 minute default.
Optional PS1 Plug-in Module
AC Input100~240VAC ± 10%. 50/60 Hz
Power Required25VA max
IsolationModule provides more than 3200VDC isolation to all other circuits
Power measurements
Definitions
Watts (power)Sum of true instantaneous per-phase power
Volt-Amps (apparent power)Sum of per-phase product of RMS voltage and RMS current, taken over the measurement interval
Power Factor (tPF)True power factor - ratio of Watts to Volt-Amps.
VAR's (volt-amps reactive)Budeanu definition
Carbon (CO2 rate and accumulated)Based on patent-pending algorithm using watts and user-selected proportions of generator sources, and user-supplied carbon generation rates for each source.
Current unbalanceMeasurement method ANSI C84.1.
Accuracy excluding external CT's
Watts (power)±0.2% at unity power factor, nominal voltage, 20% ~ 100% FS current. Class 0.5 ANSI C12.20-1998. Better than ±0.25% rdg ±0.25% FS (10% ~ 120% FS), for phase angle Θfundamental = ±30° (angle between fundamental voltage and fundamental current). Accuracy calculation: sum of voltage accuracy, plus current accuracy, plus phase angle correction which is guaranteed less than ±0.025% x (1 / cos(Θfundamental)).
Volt-Amps (apparent power)Better than ±0.25% rdg ±0.25% FS typical (10% ~ 120% FS)
Measurement Interval Phase-locked, 10-cycles (50 Hz nominal) or 12-cycles (60 Hz nominal). Approximately 5 readings per second. Actual readings per second dependent on actual frequency.
Operating Environment
Ambient Conditions - Operating-20°C ~ 50°C, 10%~90% RH
Transient Voltages - 100kHz ring wave6 kV pk, IEC 61180, IEC 61000-4-5. Applied to voltage measuring terminals with Performance Evaluation Class 1. (When applied to optional power supply mains terminal, supply's fuse may operate in PE Class 3 at test levels greater than 4 kV.)
EFT Burst Immunity4 kV pk, IEC 61000-4-4, Performance Evaluation Class 1. Applied to power measuring terminals and optional PS1 power supply mains terminals
RF Field Strength Immunity3V / m, IEC 61000-4-3 Test Level 2
Magnetic Field Strength Immunity30A / m, IEC 61000-4-8 Test Level 4
Ingress Protection Rating (IP Rating)IP20H, IEC 60529
Agency Approvals and Listings
UL (Underwriters Laboratories)UL-recognized, cULus - File Number E220936
RoHSCertified - PSL Construction File PQube-001
CECertified - PSL Construction File PQube-001, TUV CB Test Certificate US-TUVR-4368-A2
EMCCertified - 20080102-01-CE, 20080326-01-RI
TUV Bauart-markCertified - TUV Report 30880881.009

Optional Current Measuring Modules

CT4
Measurement TypePass-through (built-in current transformers)
Accuracy±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.15% rdg ±0.15% FS.
Burdenless than 0.1VA
Conductors0.34 inches (8,6mm) max. diameter, 600V UL-recognized insulation required
XCT4
Measurement TypeExternal current transformer
CT input ratio range1:1 to 10000:1
Accuracy - excluding external CT's±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.15% rdg ±0.15% FS.
BurdenLess than 0.1VA
Wire connectionMin. 20AWG (0,52 mm2), Max. 14AWG (2.1mm2). 600V UL- recognized insulation required
XCT4-0.333V-00, XCT4-1V-00, XCT4-5V-00, and XCT4-10V-00
Measurement TypeExternal current transformer
CT input ratio range1:1 to 10000:1
Nominal0.333V RMS, 1V RMS, 5V RMS, and 10V RMS
Crest Factor3.5 (± 1.17V peak, 3.5V peak, 17.5V peak, and 35V peak)
Sampling Rate12.8kHz or 15.4kHz (measured at same rate as mains voltage measuring channels)
Accuracy - excluding external CT's±0.2% rdg ±0.2% FS typical (10% ~ 120% FS). Every PQube factory tested at better than ±0.1% rdg ±0.1% FS.
Wire connectionMin. 20AWG (0,52 mm2), Max. 14AWG (2,1mm2). 600V UL- recognized insulation required
Max screw torque5 inch-pounds (0,6Nm)
Click here for complete specifications on the PSL PQube-02-0000

What's included with the PSL PQube-02-0000

  • PSL PQube-02-0000 - PQube AC Power Monitor