Photonix PX-D108M Techlite MIL MMF High Standard Fiber Optic Loss Set

Model: PX-D108M

Photonix PX-D108M Techlite MIL MMF High Standard Fiber Optic Loss Set

Model: PX-D108M

This military-grade loss test kit provides technicians with the capability to take precise optical measurements in the field. It operates in absolute power mode to measure the optical power emitted from transmitters.

This military-grade loss test kit provides technicians with the capability to take precise optical measurements in the field. It operates in absolute power mode to measure the optical power emitted from transmitters.

Your Price $2950.00 USD
Availability 2 to 3 Weeks
Quantity

Photonix PX-D108M Offers

Features

  • 850 nm/1300 nm LED source
  • 850 nm/1300 nm/1310 nm/1550 nm meter
  • Reel connector cleaner
  • DIAMOND SC, FC, and ST adapters
  • DIAMOND SMF ST-FC, ST-SC, MMF ST-SC
  • Crush resistant aluminum bodies
  • Zero reference meter with tuning bar
  • Large character meter display
  • 0.01 dB meter resolution
  • Interchangeable meter adapters
  • Controlled LED CPR operation
  • Built in quick charger
  • Laminated instruction guides
  • Sealed waterproof carring case

Applications

  • Allow technicians to perform precise optical measurements in the field

Photonix PX-D108M Specifications

LED SOURCE PX-C202M
Wavelength 850 nm, 1300 nm (±30 nm)
Fiber Size (maximum) 62.5/125
Port Style ST
Source Pmin -21 dBm
Source Stability (4hr) ±0.10 dB
Source Stability (0-50C) ±0.50 dB
Connection Stability ±0.10 dB
Source Bandwidth 35 (850 nm)/170 (1300 nm)
CPR at 850 nm 25 to 29 dB ±1.0
CPR at 1300 nm 21 to 25 dB ±0.5
Modulation CW, 30 Hz, 500 Hz, 2 kHz
Warm Up Time 15 minutes
POWER METER PX-B220M
Wavelength Range 800 to 1600 nm
Calibration Points 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Range +3 to -55 dBm
Resolution 0.01 dB
Accuracy (dB) ±0.25
Linearity (+3 to -40 dBm) ±0.30 dB
Linearity (-40 to -55 dBm) ±0.50 dB
Detector Ge, 2 mm
Operation Modes dB, dBm, Watts
Light Susceptibility 55 dBm
Operating Temperature 32 to 122°F (0 to 50°C)
Storage Temperature -4 to 140°F (0 to 50°C)
Humidity 10 to 90% non-condensing
Line Power 110/220 V AC, 50 to 60 Hz
Battery Power NiCd 4-AA or ALKALINE
Typical Battery Life 10 Hours typical
Charge Time (Trickle) 12 hours typical
Charge Time (Quick) 3 hours typical

What's included with the Photonix PX-D108M

  • Techlite Series Datalogging Optical Power Meter
  • Light Source
  • Meter Adapter Cap
  • AC Wall Pack
  • Mating Adapter and appropriate patch cords
  • Recording pads and pen
  • Serial Port cable
  • Two-Year warranty

Photonix PX-D108M Offers

Features

  • 850 nm/1300 nm LED source
  • 850 nm/1300 nm/1310 nm/1550 nm meter
  • Reel connector cleaner
  • DIAMOND SC, FC, and ST adapters
  • DIAMOND SMF ST-FC, ST-SC, MMF ST-SC
  • Crush resistant aluminum bodies
  • Zero reference meter with tuning bar
  • Large character meter display
  • 0.01 dB meter resolution
  • Interchangeable meter adapters
  • Controlled LED CPR operation
  • Built in quick charger
  • Laminated instruction guides
  • Sealed waterproof carring case

Applications

  • Allow technicians to perform precise optical measurements in the field

Photonix PX-D108M Specifications

LED SOURCE PX-C202M
Wavelength 850 nm, 1300 nm (±30 nm)
Fiber Size (maximum) 62.5/125
Port Style ST
Source Pmin -21 dBm
Source Stability (4hr) ±0.10 dB
Source Stability (0-50C) ±0.50 dB
Connection Stability ±0.10 dB
Source Bandwidth 35 (850 nm)/170 (1300 nm)
CPR at 850 nm 25 to 29 dB ±1.0
CPR at 1300 nm 21 to 25 dB ±0.5
Modulation CW, 30 Hz, 500 Hz, 2 kHz
Warm Up Time 15 minutes
POWER METER PX-B220M
Wavelength Range 800 to 1600 nm
Calibration Points 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Range +3 to -55 dBm
Resolution 0.01 dB
Accuracy (dB) ±0.25
Linearity (+3 to -40 dBm) ±0.30 dB
Linearity (-40 to -55 dBm) ±0.50 dB
Detector Ge, 2 mm
Operation Modes dB, dBm, Watts
Light Susceptibility 55 dBm
Operating Temperature 32 to 122°F (0 to 50°C)
Storage Temperature -4 to 140°F (0 to 50°C)
Humidity 10 to 90% non-condensing
Line Power 110/220 V AC, 50 to 60 Hz
Battery Power NiCd 4-AA or ALKALINE
Typical Battery Life 10 Hours typical
Charge Time (Trickle) 12 hours typical
Charge Time (Quick) 3 hours typical

What's included with the Photonix PX-D108M

  • Techlite Series Datalogging Optical Power Meter
  • Light Source
  • Meter Adapter Cap
  • AC Wall Pack
  • Mating Adapter and appropriate patch cords
  • Recording pads and pen
  • Serial Port cable
  • Two-Year warranty

More Photonix Products