The CTi LT series is a reliable solution for continuous temperature monitoring, with precise non-contact temperature measurements and easy-to-access programming keys. This has a measurement temperature range of -58 to 1922°F (-50 to 1050°C), optical resolution of 22:1, spectral range of 8 to 14 μm and 3.3' (1 m) cable.
The CTi LT series is a reliable solution for continuous temperature monitoring, with precise non-contact temperature measurements and easy-to-access programming keys. This has a measurement temperature range of -58 to 1922°F (-50 to 1050°C), optical resolution of 22:1, spectral range of 8 to 14 μm and 3.3' (1 m) cable.
The Optris CTi LT series pyrometers feature one of the world's smallest infrared sensing heads with an optical resolution of up to 22:1 and a spectral bandwidth of 8 μm to 14μm, ideal for high-emissivity targets even at low temperatures. With a wide temperature range from -58 to 1922°F (50 to 1050°C) , these pyrometers excel in non-reflecting object measurement. Their robust design allows operation up to 356°F (180°C) without additional cooling, making them optimal for high-temperature environments. Engineered in Germany, they offer precise non-contact temperature measurement with analog and digital outputs for seamless integration into machinery. Optional accessories, including mounting fork, sighting tube, close-focus lens, and air purge, enhance functionality, ensuring versatility across industrial applications.
Features
Applications
| Environmental Rating | IP 65 (NEMA-4) |
| Operating Temperature | -4 to 356°F (- 20 to 180°C) (sensing head) -4 to 356°F (-20 to 85°C) (electronics) |
| Storage Temperature | -40 to 356°F (-40 to 180°C) (sensing head) -40 to 185°F (-40 to 85°C) (electronics) |
| Operating air Humidity Range | 10 to 95 %, non condensing |
| Vibration (sensor) | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
| Shock (Sensor) | IEC 60068-2-27 (25G and 50G) |
| Output/Analog 2x) | 0/4 to 20 mA, 0 to 5/10 V, thermocouple K, alarm |
| Output/Alarm | 24V / 50 mA (open collector) |
| Relay Outputs (optional) | 2 x 60 V DC/ 42 V ACRMS; 0.4 A; optically isolated |
| Digital Interfaces | Built-in USB-interface Optional: EtherNet/IP, Profinet, Ethernet TCP/IP / Modbus TCP, Modbus RTU, RS485, RS232 or relay outputs (2 x optically isolated) |
| Output Impendances | mA max. 500 Ω (with 8 to 36 V DC) mV min. 100 kΩ load impedance Thermocouple 20 Ω |
| I/O Pins (3x) | Flexible programming as in- or output: external emissivity adjustment, ambient tempe-rature compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V/ 50 mA) |
| Cable Length | 3.3' (1 m) |
| Power Supply | 8 to 30 V DC / 1.2W |
| Measuring Temperature Range | -58 to 1922°F (- 50 to 1050°C) |
| Spectral Range | 8 to 14 μm |
| Optical Resolution (90%) | 22:1 |
| Measurment Uncertainty | ±1 % or ±1°C |
| Repeatability | ±0.15°C or ± 0.1% |
| Temperature Resolution (Display) | 0.1 K |
| NETD (Typically) | 35 mK |
| Response Time (90% energy) | 115 ms |
| Emmisivity/Gain | 0.05 to 1.1 |
| Transmissivity/Gain | 0.05 to 1.1 |
| Signal Processing | Peak hold, valley hold, average; extended hold functions with threshold and hysteresis |
| Software/App | Optris CompactPlus Connect / IR Mobile App |
| Dimension | Sensing head: Ø0.47 x 1.38" (Ø12 x 35 mm), M12x1 Electronics: 4.8 x 2.8 x 1.1" (122 x 70 x 27 mm) |
| Weight | 1.41 oz (40 g) (sensing head) 14.82 oz (420 g) (electronics) |
| Environmental Rating | IP 65 (NEMA-4) |
| Operating Temperature | -4 to 356°F (- 20 to 180°C) (sensing head) -4 to 356°F (-20 to 85°C) (electronics) |
| Storage Temperature | -40 to 356°F (-40 to 180°C) (sensing head) -40 to 185°F (-40 to 85°C) (electronics) |
| Operating air Humidity Range | 10 to 95 %, non condensing |
| Vibration (sensor) | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
| Shock (Sensor) | IEC 60068-2-27 (25G and 50G) |
| Output/Analog 2x) | 0/4 to 20 mA, 0 to 5/10 V, thermocouple K, alarm |
| Output/Alarm | 24V / 50 mA (open collector) |
| Relay Outputs (optional) | 2 x 60 V DC/ 42 V ACRMS; 0.4 A; optically isolated |
| Digital Interfaces | Built-in USB-interface Optional: EtherNet/IP, Profinet, Ethernet TCP/IP / Modbus TCP, Modbus RTU, RS485, RS232 or relay outputs (2 x optically isolated) |
| Output Impendances | mA max. 500 Ω (with 8 to 36 V DC) mV min. 100 kΩ load impedance Thermocouple 20 Ω |
| I/O Pins (3x) | Flexible programming as in- or output: external emissivity adjustment, ambient tempe-rature compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V/ 50 mA) |
| Cable Length | 3.3' (1 m) |
| Power Supply | 8 to 30 V DC / 1.2W |
| Measuring Temperature Range | -58 to 1922°F (- 50 to 1050°C) |
| Spectral Range | 8 to 14 μm |
| Optical Resolution (90%) | 22:1 |
| Measurment Uncertainty | ±1 % or ±1°C |
| Repeatability | ±0.15°C or ± 0.1% |
| Temperature Resolution (Display) | 0.1 K |
| NETD (Typically) | 35 mK |
| Response Time (90% energy) | 115 ms |
| Emmisivity/Gain | 0.05 to 1.1 |
| Transmissivity/Gain | 0.05 to 1.1 |
| Signal Processing | Peak hold, valley hold, average; extended hold functions with threshold and hysteresis |
| Software/App | Optris CompactPlus Connect / IR Mobile App |
| Dimension | Sensing head: Ø0.47 x 1.38" (Ø12 x 35 mm), M12x1 Electronics: 4.8 x 2.8 x 1.1" (122 x 70 x 27 mm) |
| Weight | 1.41 oz (40 g) (sensing head) 14.82 oz (420 g) (electronics) |