Record temperatures in indoor environments with this single-channel thermocouple data logger. Designed for a broad range of temperature monitoring applications, this data logger is compatible with J, K, T, E, R, S, B, or N-type thermocouple probes.
Record temperatures in indoor environments with this single-channel thermocouple data logger. Designed for a broad range of temperature monitoring applications, this data logger is compatible with J, K, T, E, R, S, B, or N-type thermocouple probes.
| Thermocouple | |
| J | Range: -346 to 1400°F (-210 to 760°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.06°F (0.03°C) |
| Internal 10K Thermistor (Temperature) | |
| Drift | 0.18°F (<0.1°C) per year |
| Thermocouple | |
| K | Range: -436 to 2498°F (-260 to 1370°C) Accuracy: ±1.26°F (±0.7°C) ±thermocouple probe accuracy Resolution: 0.07°F (0.04°C) |
| T | Range: -436 to 752°F (-260 to 400°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.03°F (0.02°C) |
| E | Range: -436 to 1742°F (-260 to 950°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.05°F at (0.03°C) |
| R | Range: -58 to 2822°F (-50 to 1550°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
| S | Range: -58 to 3128°F (-50 to 1720°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
| B | Range: 1022 to 3308°F (550 to 1820°C) Accuracy: ±4.5°F (±2.5°C) ±thermocouple probe accuracy Resolution: 0.18°F (0.1°C) |
| N | Range: -436 to 2372°F (-260 to 1300°C) Accuracy: ±1.8°F (±1.0°C) ±thermocouple probe accuracy Resolution: 0.11°F (0.06°C) |
| Internal 10K Thermistor (Temperature) | |
| Logging Range | -4 to 158°F (-20 to 70°C) |
| Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
| Resolution | 0.04°F at 77°F (0.024°C at 25°C) |
| Logger | |
| Operating Range | Logging: -4 to 158°F (-20 to 70°C); 0 to 95% RH (non-condensing); logger accuracy from 32 to 122°F (0 to 50°C) Launch/Readout: 32 to 122°F (0 to 50°C) per USB specification |
| Resolution | 22-bit |
| Logging | Rate: 1 second to 18 hours, 12 minutes, 15 seconds Modes: Normal, Burst or Statistics |
| Modes | Memory: Wrap when full or stop when full Start: Immediately, push button, date and time or next interval Stop: When memory full, push button, or date and time Restart: Push button |
| Time Accuracy | ±1 minute per month at 77°F (25°C) |
| Battery | Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Type: 1 x 3 V CR2032 lithium battery |
| Environmental Rating | IP50 |
| Dimensions | 1.44 x 2.34 x 0.6" (3.66 x 5.94 x 1.52 cm) |
| Weight | 1.06 oz (30 g) |
Click on a category to view a selection of compatible accessories with the Onset HOBO UX100-014M Thermocouple Data Logger, single-channel.