Suited for signal transmission, this programmable transmitter supports universal sensor input and 4 to 20 mA process output. In addition, it features hockey-puck mounting, 2-wire DC supply, -12 to 800 mV input range, and universal input/process output configuration. It suits converting sensor inputs into standard process output signals.
Suited for signal transmission, this programmable transmitter supports universal sensor input and 4 to 20 mA process output. In addition, it features hockey-puck mounting, 2-wire DC supply, -12 to 800 mV input range, and universal input/process output configuration. It suits converting sensor inputs into standard process output signals.
Features
Applications
| ADC Resolution | 20 bit |
| Specifications range | -40°C to +85°C |
| Accuracy | ±0.05 % ≤ ±0.05% of span |
| Supply voltage, DC (Standard) | 7.2 to 35 VDC |
| Cable Resistance | 5 Ω |
| Internal power dissipation (Standard) | 25 mW to 0.8 W |
| Input Control Signal | -12 to 800 mV |
| Voltage drop | 7.2 VDC |
| Input Resistance | 10 MΩ |
| Isolation voltage, test / operation | 1.5 kVAC / 50 VAC |
| Isolation | 1500 V |
| Warm-up time | 5 min |
| Electrical Connection | Screw terminal |
| Communications interface | Loop Link |
| Electrical Output | 4 to 20 mA |
| Signal / noise ratio | Min. 60 dB |
| Operating Temperature | -40 to 185°F (-40 to 85°C) |
| Response time (programmable) | 1 to 60 s |
| EEprom error check | < 3.5 s |
| Signal dynamics, input | 20 bit |
| Signal dynamics, output | 16 bit |
| Calibration temperature | 20 to 28°C |
| Absolute accuracy (all input types) | ≤ ±0.05% of span |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| Basic accuracy, RTD | ≤ ±0.2°C |
| Temperature coefficient, RTD | ≤ ±0.01°C/°C |
| Basic accuracy, Lin. R | ≤ ±0.1 Ω |
| Temperature coefficient, Lin. R | ≤ ±10 mΩ / °C |
| Basic accuracy, Volt | ≤ ±10 µV |
| Temperature coefficient, Volt | ≤ ±1 µV / °C |
| Basic accuracy, TC type E, J, K, L, N, T, U | ≤ ±1°C |
| Temperature coefficient, TC type E, J, K, L, N, T, U | ≤ ±0.05°C / °C |
| Basic accuracy, TC type B, R, S, W3, W5, LR | ≤ ±2°C |
| Temperature coefficient, TC type B, R, S, W3, W5, LR | ≤ ±0.2°C / °C |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Effect of supply voltage variation | < 0.005% of span/VDC |
| Vibration | IEC 60068-2-6 : 2007 |
| Vibration, 2 to 25 Hz | ±1.6 mm |
| Vibration, 25 to 100 Hz | ±4 g |
| Max. wire size | 1 x 1.5 mm2 stranded wire |
| Screw terminal torque | 0.4 Nm |
| Humidity | < 95% RH (non-cond.) |
| Protection degree (enclosure / terminal) | IP68/IP00 |
| RTD and linear resistance input, max. offset | 50% of selected max. value |
| Cable resistance per wire (max.) | 5 Ω |
| Sensor current | nom. 0.2 mA |
| Effect of sensor cable resistance (3- / 4-wire) | < 0.002 Ω/Ω |
| Sensor error detection (RTD/resistance input) | Yes |
| TC input, max. offset | 50% of selected max. value |
| Cold junction compensation | < ±1.0°C |
| Sensor error detection (TC input) | Yes |
| Sensor error current, when detecting | Nom. 33 mA |
| Sensor error current, else | 0 mA |
| Voltage input, measurement range | -12 to 800 mV |
| Voltage input, min. span | 5 mV |
| Voltage input, max. offset | 50% of selected max. value |
| Input resistance | 10 MΩ |
| Current output, signal range | 4 to 20 mA |
| Current output, min. signal range | 16 mA |
| Updating time | 440 ms |
| Output signal at EEprom error | ≤ 3.5 mA |
| Load resistance | ≤ (Vsupply - 7.2) / 0.023 [Ω] |
| Load stability | < ±0.01% of span / 100 Ω |
| Sensor error detection, programmable | 3.5 to 23 mA |
| Namur NE43 Upscale | 23 mA |
| Namur NE43 Downscale | 3.5 mA |
| EMC | 2014/30/EU |
| CCOE | P337392/1 |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
| FM certificate | FM17US0013X |
| Dimensions | Ø 44 mm x 20.2 mm mounting hole: ø 6 mm width across flats: 33 mm |
| Weight | 50 g |
| ADC Resolution | 20 bit |
| Specifications range | -40°C to +85°C |
| Accuracy | ±0.05 % ≤ ±0.05% of span |
| Supply voltage, DC (Standard) | 7.2 to 35 VDC |
| Cable Resistance | 5 Ω |
| Internal power dissipation (Standard) | 25 mW to 0.8 W |
| Input Control Signal | -12 to 800 mV |
| Voltage drop | 7.2 VDC |
| Input Resistance | 10 MΩ |
| Isolation voltage, test / operation | 1.5 kVAC / 50 VAC |
| Isolation | 1500 V |
| Warm-up time | 5 min |
| Electrical Connection | Screw terminal |
| Communications interface | Loop Link |
| Electrical Output | 4 to 20 mA |
| Signal / noise ratio | Min. 60 dB |
| Operating Temperature | -40 to 185°F (-40 to 85°C) |
| Response time (programmable) | 1 to 60 s |
| EEprom error check | < 3.5 s |
| Signal dynamics, input | 20 bit |
| Signal dynamics, output | 16 bit |
| Calibration temperature | 20 to 28°C |
| Absolute accuracy (all input types) | ≤ ±0.05% of span |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| Basic accuracy, RTD | ≤ ±0.2°C |
| Temperature coefficient, RTD | ≤ ±0.01°C/°C |
| Basic accuracy, Lin. R | ≤ ±0.1 Ω |
| Temperature coefficient, Lin. R | ≤ ±10 mΩ / °C |
| Basic accuracy, Volt | ≤ ±10 µV |
| Temperature coefficient, Volt | ≤ ±1 µV / °C |
| Basic accuracy, TC type E, J, K, L, N, T, U | ≤ ±1°C |
| Temperature coefficient, TC type E, J, K, L, N, T, U | ≤ ±0.05°C / °C |
| Basic accuracy, TC type B, R, S, W3, W5, LR | ≤ ±2°C |
| Temperature coefficient, TC type B, R, S, W3, W5, LR | ≤ ±0.2°C / °C |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Effect of supply voltage variation | < 0.005% of span/VDC |
| Vibration | IEC 60068-2-6 : 2007 |
| Vibration, 2 to 25 Hz | ±1.6 mm |
| Vibration, 25 to 100 Hz | ±4 g |
| Max. wire size | 1 x 1.5 mm2 stranded wire |
| Screw terminal torque | 0.4 Nm |
| Humidity | < 95% RH (non-cond.) |
| Protection degree (enclosure / terminal) | IP68/IP00 |
| RTD and linear resistance input, max. offset | 50% of selected max. value |
| Cable resistance per wire (max.) | 5 Ω |
| Sensor current | nom. 0.2 mA |
| Effect of sensor cable resistance (3- / 4-wire) | < 0.002 Ω/Ω |
| Sensor error detection (RTD/resistance input) | Yes |
| TC input, max. offset | 50% of selected max. value |
| Cold junction compensation | < ±1.0°C |
| Sensor error detection (TC input) | Yes |
| Sensor error current, when detecting | Nom. 33 mA |
| Sensor error current, else | 0 mA |
| Voltage input, measurement range | -12 to 800 mV |
| Voltage input, min. span | 5 mV |
| Voltage input, max. offset | 50% of selected max. value |
| Input resistance | 10 MΩ |
| Current output, signal range | 4 to 20 mA |
| Current output, min. signal range | 16 mA |
| Updating time | 440 ms |
| Output signal at EEprom error | ≤ 3.5 mA |
| Load resistance | ≤ (Vsupply - 7.2) / 0.023 [Ω] |
| Load stability | < ±0.01% of span / 100 Ω |
| Sensor error detection, programmable | 3.5 to 23 mA |
| Namur NE43 Upscale | 23 mA |
| Namur NE43 Downscale | 3.5 mA |
| EMC | 2014/30/EU |
| CCOE | P337392/1 |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
| FM certificate | FM17US0013X |
| Dimensions | Ø 44 mm x 20.2 mm mounting hole: ø 6 mm width across flats: 33 mm |
| Weight | 50 g |