Image is for reference only, refer to product info for complete details.
Made for instrument calibration, this RTD capsule pairs a Pt100 element 3-wire at high-accuracy tolerance with a measuring range of 500°F (260°C).
Made for instrument calibration, this RTD capsule pairs a Pt100 element 3-wire at high-accuracy tolerance with a measuring range of 500°F (260°C).
Ready to use platinum RTD capsules have insulated lead wires welded and anchored internally. No splicing to fragile elements is required. This construction assures reliable rugged embedment, insertion or probe assembly.
Tip diameters from 0.086 to 0.125" (2.2 to 3.2 mm). Standard sensors and encapsulation materials rated up to 1004°F (540°C). Choose the moisture resistant version for condensing conditions.
Features
Applications
| Series | RTDCAP Series |
| Type | RTD Capsule |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | ± 0.15 + 0.002* t °C |
| Temperature range | 500°F (260°C) |
| Wiring | 3 wire |
| Standard Lead Length | 40" (1 m) |
| Operating Range - TFE Leads | -328 to 500°F (-200 to 260°C) |
| Operating Range - Polyimide Leads | -328 to 662°F (-200 to 350°C) |
| Operating Range - Fiberglass Leads | -103 to 950°F (-75 to 510°C) |
| Operating Range - Moisture Resistant | -58 to 392°F (-50 to 200°C) |
| Ice Point Resistance | 100.00±0.06 Ω or 1000.0±0.6 Ω at 0°C |
| Time Constant (Water at 3'/Second) | 0.086 Diameter = 0.5 seconds; 0.098 Diameter = 0.6 seconds; 0.125 Diameter = 0.8 seconds; 0.187 Diameter = 1.5 seconds |
| Self-Heating | Greater than 15 mW/°C |
| Insulation Resistance | Greater than 50 Megohms at 50 V DC at 77°F (25°C) |
| Interchangeability/Accuracy | Class A (±0.15+.002*|t|°C [where |t|= absolute value of temperature in °C]) between -50 and 300°C, Class B above and below these temperatures |
| Maximum Current | 100 Ω = 5 mA, 1000 Ω = 2 mA for limited self-heating; also suitable as self-heated sensors |
| Recommended Current | 1 mA maximum for temperature sensing |
| Long Term Stability | Better than 0.05°C (0.02% of resistance) per 5 years, -58 to 572°F (-50 to 300°C), 0.25°C per year to 1004°F (540°C) |
| Case Materials | Alumina on 0.125 and 0.086 diameter, Polyimide [662°F (350°C)] on 0.098 diameter |
| Lead Materials (Nickel-Coated Copper-Insulated) | 28 AWG Fiberglass: Rated to 950°F (510°C); 28 AWG TFE: Rated to 500°F (260°C); 28 AWG Polyimide: Rated to 662°F (350°C) |
| Encapsulation rating | Standard sensors and encapsulation materials rated up to 1004°F (540°C) |
| Tip diameters | 0.086 to 0.125" (2.2 to 3.2 mm) |
| Length Tolerance | ±0.06" (1.5 mm) |
| Diameter Tolerance | ±0.01" (0.3 mm) |
| Series | RTDCAP Series |
| Type | RTD Capsule |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | ± 0.15 + 0.002* t °C |
| Temperature range | 500°F (260°C) |
| Wiring | 3 wire |
| Standard Lead Length | 40" (1 m) |
| Operating Range - TFE Leads | -328 to 500°F (-200 to 260°C) |
| Operating Range - Polyimide Leads | -328 to 662°F (-200 to 350°C) |
| Operating Range - Fiberglass Leads | -103 to 950°F (-75 to 510°C) |
| Operating Range - Moisture Resistant | -58 to 392°F (-50 to 200°C) |
| Ice Point Resistance | 100.00±0.06 Ω or 1000.0±0.6 Ω at 0°C |
| Time Constant (Water at 3'/Second) | 0.086 Diameter = 0.5 seconds; 0.098 Diameter = 0.6 seconds; 0.125 Diameter = 0.8 seconds; 0.187 Diameter = 1.5 seconds |
| Self-Heating | Greater than 15 mW/°C |
| Insulation Resistance | Greater than 50 Megohms at 50 V DC at 77°F (25°C) |
| Interchangeability/Accuracy | Class A (±0.15+.002*|t|°C [where |t|= absolute value of temperature in °C]) between -50 and 300°C, Class B above and below these temperatures |
| Maximum Current | 100 Ω = 5 mA, 1000 Ω = 2 mA for limited self-heating; also suitable as self-heated sensors |
| Recommended Current | 1 mA maximum for temperature sensing |
| Long Term Stability | Better than 0.05°C (0.02% of resistance) per 5 years, -58 to 572°F (-50 to 300°C), 0.25°C per year to 1004°F (540°C) |
| Case Materials | Alumina on 0.125 and 0.086 diameter, Polyimide [662°F (350°C)] on 0.098 diameter |
| Lead Materials (Nickel-Coated Copper-Insulated) | 28 AWG Fiberglass: Rated to 950°F (510°C); 28 AWG TFE: Rated to 500°F (260°C); 28 AWG Polyimide: Rated to 662°F (350°C) |
| Encapsulation rating | Standard sensors and encapsulation materials rated up to 1004°F (540°C) |
| Tip diameters | 0.086 to 0.125" (2.2 to 3.2 mm) |
| Length Tolerance | ±0.06" (1.5 mm) |
| Diameter Tolerance | ±0.01" (0.3 mm) |