Designed for humidifying control and environmental chambers, this relative humidity on/off controller provides 0 to 3 V DC I/P, 110 V AC Supply, 25 to 90 %RH. It has relative humidity range of 0 to 100% RH.
Designed for humidifying control and environmental chambers, this relative humidity on/off controller provides 0 to 3 V DC I/P, 110 V AC Supply, 25 to 90 %RH. It has relative humidity range of 0 to 100% RH.
The microprocessor based RHCN-7000 Series on/off controller provides control for humidifying or de-humidifying. Relative humidity, output status, and error messaging can be viewed on the bright green LED display. The controller features user defined parameters including setpoint, hysteresis, control type, and probe adjustment.
Features
Applications
| Series | RHCN-7000 Series |
| Type | relative humidity on/off controller |
| Input | 0 V DC to 3 V DC I/P |
| Supply voltage | 110 V AC Supply |
| Configuration | 25 %RH to 90 %RH |
| Display | 3 Digit |
| Configuration | LED Display |
| Output type | 8 A SPDT Relay O/P |
| Relative Humidity Range | 0 to 100% RH |
| Input | 0 to 3 or 0 to 1 V DC or 4 to 20 mA (depending on model) |
| Accuracy | ±1% RH |
| Display | 3-digit, green, 0.5" (12.7 mm) digits |
| Resolution | 1-digit |
| Output | 8 A SPDT relay @ 250 V AC resistive |
| Horsepower Rating (HP) | 1/3 HP |
| Control Type | ON/OFF |
| Power Requirements | 110 or 230 V AC (depending on model) |
| Memory Backup | Nonvolatile memory |
| Temperature Limits | 32 to 158°F (0 to 70°C) |
| Front Panel Rating | IP64 |
| Storage Temperature | -4 to 176°F (-20 to 80°C) |
| Optional Probe Output (RHCN-7000-RP) | 0 to 3 V DC |
| Optional Probe Relative Humidity Range | 25 to 90% RH (probe only) |
| Optional Probe Accuracy | ±5% RH @ 77°F (25°C) |
| System Accuracy (Instrument and Optional Probe) | ±6% RH |
| Panel Cutout Dimensions | 2.80 x 1.14" (71 x 29 mm) |
| Optional Probe Dimensions | 2.5 x 0.98" (64 x 25 mm),4' (1.22 m) cable |
| Weight | 2.3 oz (65 g) |
| Series | RHCN-7000 Series |
| Type | relative humidity on/off controller |
| Input | 0 V DC to 3 V DC I/P |
| Supply voltage | 110 V AC Supply |
| Configuration | 25 %RH to 90 %RH |
| Display | 3 Digit |
| Configuration | LED Display |
| Output type | 8 A SPDT Relay O/P |
| Relative Humidity Range | 0 to 100% RH |
| Input | 0 to 3 or 0 to 1 V DC or 4 to 20 mA (depending on model) |
| Accuracy | ±1% RH |
| Display | 3-digit, green, 0.5" (12.7 mm) digits |
| Resolution | 1-digit |
| Output | 8 A SPDT relay @ 250 V AC resistive |
| Horsepower Rating (HP) | 1/3 HP |
| Control Type | ON/OFF |
| Power Requirements | 110 or 230 V AC (depending on model) |
| Memory Backup | Nonvolatile memory |
| Temperature Limits | 32 to 158°F (0 to 70°C) |
| Front Panel Rating | IP64 |
| Storage Temperature | -4 to 176°F (-20 to 80°C) |
| Optional Probe Output (RHCN-7000-RP) | 0 to 3 V DC |
| Optional Probe Relative Humidity Range | 25 to 90% RH (probe only) |
| Optional Probe Accuracy | ±5% RH @ 77°F (25°C) |
| System Accuracy (Instrument and Optional Probe) | ±6% RH |
| Panel Cutout Dimensions | 2.80 x 1.14" (71 x 29 mm) |
| Optional Probe Dimensions | 2.5 x 0.98" (64 x 25 mm),4' (1.22 m) cable |
| Weight | 2.3 oz (65 g) |