Rated at ±0.4% accuracy, this thin-film transducer measures 0 to 5000 psi gauge pressure and provides a 4 to 20 mA output through a cable lead. Zero and span adjustments allow field tuning. It is used for gas pressure measurement and pump and compressor monitoring.
Rated at ±0.4% accuracy, this thin-film transducer measures 0 to 5000 psi gauge pressure and provides a 4 to 20 mA output through a cable lead. Zero and span adjustments allow field tuning. It is used for gas pressure measurement and pump and compressor monitoring.
These thin-film transducers measure gauge, vacuum, or compound ranges in rugged stainless steel construction from vacuum to 20,000 psi (1380 bar). The thin-film design provides high reliability and excellent long-term stability, and every unit includes zero and span adjustments. The wetted diaphragm is 17-4 PH stainless steel and the case is 300 series stainless steel for use with liquid or gas media.
Features
Applications
| Series | PX605 Series |
| Type | Thin-film pressure transducer |
| Pressure type | Gauge |
| Pressure range | 0 to 5000 psi (0 to 345 bar) |
| Output | 4 to 20 mA |
| Excitation | 10 to 36 V DC |
| Supply current | <3.0 mA |
| Accuracy | ±0.4% BFSL |
| Hysteresis | ±0.2% of full scale |
| Repeatability | ±0.05% of full scale |
| Zero and span | Adjustable |
| Insulation resistance | 100 MΩ at 50 V |
| Stability | ±1.0% per year |
| Durability | 100 million cycles |
| Proof pressure | 150% of full scale |
| Burst pressure | 500% of full scale |
| Operating temperature | -55 to 195°F (-48 to 90°C) |
| Compensated temperature | -20 to 180°F (-29 to 82°C) |
| Thermal zero effect | ±0.07% of full scale/°C |
| Thermal span effect | ±0.07% of full scale/°C |
| Response time | 5 milliseconds |
| Sensing element | Thin-film polysilicone gauges |
| Wetted diaphragm | 17-4 PH stainless steel |
| Case | 300 series stainless steel |
| Pressure port | 1/4 NPT Male |
| Electrical connection | 36" (0.9 m) braided-shield PVC cable |
| Construction | Sealed |
| Enclosure rating | NEMA 4 (IP65) |
| Dimensions | 3.78" (96 mm) length x 0.8" (20.3 mm) diameter |
| Weight | 4.5 oz (128 g) without cable |
| Series | PX605 Series |
| Type | Thin-film pressure transducer |
| Pressure type | Gauge |
| Pressure range | 0 to 5000 psi (0 to 345 bar) |
| Output | 4 to 20 mA |
| Excitation | 10 to 36 V DC |
| Supply current | <3.0 mA |
| Accuracy | ±0.4% BFSL |
| Hysteresis | ±0.2% of full scale |
| Repeatability | ±0.05% of full scale |
| Zero and span | Adjustable |
| Insulation resistance | 100 MΩ at 50 V |
| Stability | ±1.0% per year |
| Durability | 100 million cycles |
| Proof pressure | 150% of full scale |
| Burst pressure | 500% of full scale |
| Operating temperature | -55 to 195°F (-48 to 90°C) |
| Compensated temperature | -20 to 180°F (-29 to 82°C) |
| Thermal zero effect | ±0.07% of full scale/°C |
| Thermal span effect | ±0.07% of full scale/°C |
| Response time | 5 milliseconds |
| Sensing element | Thin-film polysilicone gauges |
| Wetted diaphragm | 17-4 PH stainless steel |
| Case | 300 series stainless steel |
| Pressure port | 1/4 NPT Male |
| Electrical connection | 36" (0.9 m) braided-shield PVC cable |
| Construction | Sealed |
| Enclosure rating | NEMA 4 (IP65) |
| Dimensions | 3.78" (96 mm) length x 0.8" (20.3 mm) diameter |
| Weight | 4.5 oz (128 g) without cable |