Measuring 0 to 2000 psi (0 to 138 bar) gauge pressure, this subminiature pressure transducer provides a 2 mV/V ratiometric output at ±1% accuracy. It suits industrial pressure monitoring and hydraulic measurement.
Measuring 0 to 2000 psi (0 to 138 bar) gauge pressure, this subminiature pressure transducer provides a 2 mV/V ratiometric output at ±1% accuracy. It suits industrial pressure monitoring and hydraulic measurement.
The PX600 Series is a subminiature flush diaphragm pressure transducer with all stainless steel diaphragm and threaded sidewall construction. A rugged stainless steel case protects components in industrial environments. Custom subminiature design techniques provide small size and preserve accuracy, and the unit uses a standard 5 V DC regulated power supply for maximum versatility.
Features
Applications
| Series | PX600 Series |
| Type | Subminiature flush diaphragm pressure transducer |
| Pressure type | Gauge |
| Pressure range | 0 to 2000 psi (0 to 138 bar) |
| Accuracy | ±1% full scale (linearity and hysteresis combined) |
| Repeatability | ±0.1% full scale |
| Output | 10 mV typical at 5 V DC |
| Sensitivity | 2 mV/V nominal |
| Excitation | 5 V DC at 15 mA |
| Input impedance | 350 Ω minimum |
| Output resistance | 350 Ω minimum |
| Insulation resistance | 5 MΩ at 75 V DC |
| Zero balance | ±3% full scale |
| Thermal zero effect | <±0.018% full scale/°C |
| Thermal sensitivity effect | ±0.036% reading/°C |
| Proof pressure | 150% of range |
| Burst pressure | 400% of range |
| Body and diaphragm | 17-4 PH stainless steel |
| Pressure port | 3/8-24 thread |
| O-ring | 2-011 FKM |
| Electrical connection | 4-conductor cable, 5' (1.5 m) |
| Compensated temperature | 60 to 160°F (16 to 71°C) |
| Operating temperature | -65 to 250°F (-54 to 121°C) |
| Weight | Net weight: 0.03 lbs (14 g) |
| Series | PX600 Series |
| Type | Subminiature flush diaphragm pressure transducer |
| Pressure type | Gauge |
| Pressure range | 0 to 2000 psi (0 to 138 bar) |
| Accuracy | ±1% full scale (linearity and hysteresis combined) |
| Repeatability | ±0.1% full scale |
| Output | 10 mV typical at 5 V DC |
| Sensitivity | 2 mV/V nominal |
| Excitation | 5 V DC at 15 mA |
| Input impedance | 350 Ω minimum |
| Output resistance | 350 Ω minimum |
| Insulation resistance | 5 MΩ at 75 V DC |
| Zero balance | ±3% full scale |
| Thermal zero effect | <±0.018% full scale/°C |
| Thermal sensitivity effect | ±0.036% reading/°C |
| Proof pressure | 150% of range |
| Burst pressure | 400% of range |
| Body and diaphragm | 17-4 PH stainless steel |
| Pressure port | 3/8-24 thread |
| O-ring | 2-011 FKM |
| Electrical connection | 4-conductor cable, 5' (1.5 m) |
| Compensated temperature | 60 to 160°F (16 to 71°C) |
| Operating temperature | -65 to 250°F (-54 to 121°C) |
| Weight | Net weight: 0.03 lbs (14 g) |