Made for timing control of machinery and process equipment, this DIN-rail digital timer uses a 4-digit backlit LCD with 24 programmable timing modes and time ranges from 1 sec to 9999 minimum. It provides one changeover and one N/O relay output and is powered from 24 to 240 V AC/DC. It measures only 36 mm wide, has a clear hinged tamperproof cover, and uses EEPROM memory.
Made for timing control of machinery and process equipment, this DIN-rail digital timer uses a 4-digit backlit LCD with 24 programmable timing modes and time ranges from 1 sec to 9999 minimum. It provides one changeover and one N/O relay output and is powered from 24 to 240 V AC/DC. It measures only 36 mm wide, has a clear hinged tamperproof cover, and uses EEPROM memory.
The Omega PTC-16-A digital timer is a 4 digit multifunction, multi-time range timer suitable for controlling the operation of equipment, machinery, systems or processes in a wide range of industrial applications. This dual digital timer has two relay outputs which can be configured as two independent timed outputs. A choice of 24 timing function modes can be selected for each of the outputs, together with a time range from 1 second to 9999 minutes. The output contacts are fully isolated from the supply voltage. These timers are housed in a compact DIN rail mounting enclosure measuring only 36 mm in width and are powered from a wide range of 24 to 240 V AC/dc.
Features
Applications
| Accuracy | ±3 sec/24 hours |
| Power supply voltage | 24 to 240 V AC |
| Burden | <3 VA |
| Frequency | 50/60 Hz |
| Time ranges | 0 to 9999 sec, 0 to 9999 minimum |
| Relay output | Single pole changeover contact and single pole N/O contact |
| Contact rating | OP1 8 A at 250 V AC/30 V DC (resistive); OP2 8 A at 250 V AC/30 V DC (resistive) |
| Electrical contact life | 100,000 operations |
| Reset time | 100 ms approx. |
| Enclosure | Panel mounting to DIN 43700, self extinguishing plastic case, plug in connection terminals |
| Enclosure code | Case IP20 |
| Operating temperature | 23°F to 113°F (-5°C to 45°C) |
| Storage temperature | 14°F to 131°F (-10°C to 55°C) |
| Markings | CE marked (meets EN61010-1:2010 low voltage and EN61326-1:2013 EMC directives) |
| Weight | Weight: 0.31 lb (140 g) |
| Accuracy | ±3 sec/24 hours |
| Power supply voltage | 24 to 240 V AC |
| Burden | <3 VA |
| Frequency | 50/60 Hz |
| Time ranges | 0 to 9999 sec, 0 to 9999 minimum |
| Relay output | Single pole changeover contact and single pole N/O contact |
| Contact rating | OP1 8 A at 250 V AC/30 V DC (resistive); OP2 8 A at 250 V AC/30 V DC (resistive) |
| Electrical contact life | 100,000 operations |
| Reset time | 100 ms approx. |
| Enclosure | Panel mounting to DIN 43700, self extinguishing plastic case, plug in connection terminals |
| Enclosure code | Case IP20 |
| Operating temperature | 23°F to 113°F (-5°C to 45°C) |
| Storage temperature | 14°F to 131°F (-10°C to 55°C) |
| Markings | CE marked (meets EN61010-1:2010 low voltage and EN61326-1:2013 EMC directives) |
| Weight | Weight: 0.31 lb (140 g) |