Made for measuring molten metals, asphalt, and concrete from a distance, this high-performance infrared thermometer measures -58 to 2822°F (-50 to 1550°C) with a 30:1 field of view. It reads to ±1.5% ± 2°C from 0 to 500°C with a response under 250 ms and adjustable 0.10 to 1.00 emissivity. It uses dual laser sighting for accurate targeting of far-away, very hot surfaces.
Made for measuring molten metals, asphalt, and concrete from a distance, this high-performance infrared thermometer measures -58 to 2822°F (-50 to 1550°C) with a 30:1 field of view. It reads to ±1.5% ± 2°C from 0 to 500°C with a response under 250 ms and adjustable 0.10 to 1.00 emissivity. It uses dual laser sighting for accurate targeting of far-away, very hot surfaces.
The OS836-Series high performance infrared thermometer boasts 30 to 1 field of view, -50 to 1550°C temperature range and ±2% accuracy above 0°C. This series device is great for non-contact measurement of surfaces that are far away and very high temperatures. Applications such as molten metals, asphalt, oil, rubber, concrete and many more. The 30:1 field of view, or distance to spot ratio, allows for precise measurement even from a larger distance.
Features
Applications
| Temperature range | -58 to 2822°F (-50 to 1550°C) |
| Accuracy | ±4.0°C (7.2°F): -50°C to 0°C (-58°F to 32°F) |
| Accuracy | ±1.5% ± 2.0°C (3.6°F): 0°C to 500°C (32°F to 932°F) |
| Accuracy | ±2.0% ± 2.0°C (3.6°F): >500°C (932°F) |
| Field of view | 30:1 |
| Repeatability | 1% of reading or 1°C |
| Response time | <250 ms (95% response) |
| Spectral response | 8 – 14 µm |
| Emissivity | Adjustable 0.10 – 1.00 |
| Operating temperature range | 32 to 120°F (0 to 50°C) |
| Relative humidity | 10 - 90% RH, Storage <80% RH |
| Storage temperature | -4 to 140°F (-20 to 60°C) |
| Record memory | 99 records |
| Power | 9 V battery |
| Estimated battery life | 16 Hours |
| Dimensions | 7.80 x 4.72 x 2.32" (198 x 120 x 59 mm) |
| Weight | Weight: 10.1 oz (286 g) |
| Temperature range | -58 to 2822°F (-50 to 1550°C) |
| Accuracy | ±4.0°C (7.2°F): -50°C to 0°C (-58°F to 32°F) |
| Accuracy | ±1.5% ± 2.0°C (3.6°F): 0°C to 500°C (32°F to 932°F) |
| Accuracy | ±2.0% ± 2.0°C (3.6°F): >500°C (932°F) |
| Field of view | 30:1 |
| Repeatability | 1% of reading or 1°C |
| Response time | <250 ms (95% response) |
| Spectral response | 8 – 14 µm |
| Emissivity | Adjustable 0.10 – 1.00 |
| Operating temperature range | 32 to 120°F (0 to 50°C) |
| Relative humidity | 10 - 90% RH, Storage <80% RH |
| Storage temperature | -4 to 140°F (-20 to 60°C) |
| Record memory | 99 records |
| Power | 9 V battery |
| Estimated battery life | 16 Hours |
| Dimensions | 7.80 x 4.72 x 2.32" (198 x 120 x 59 mm) |
| Weight | Weight: 10.1 oz (286 g) |