Omega OM-CP-RFPRHTEMP2000A Wireless Pressure, Humidity and Temperature Data Logger, USB

Model: OM-CP-RFPRHTEMP2000A

Omega OM-CP-RFPRHTEMP2000A Wireless Pressure, Humidity and Temperature Data Logger, USB

Model: OM-CP-RFPRHTEMP2000A

With Humidity & Temperature Data Logger, 3-CH, Battery, this wireless pressure, humidity and temperature data logger is used for weather data monitoring and storage and warehouse environment monitoring. It has temperature range of -4 to 140°F (-20 to 60°C).

With Humidity & Temperature Data Logger, 3-CH, Battery, this wireless pressure, humidity and temperature data logger is used for weather data monitoring and storage and warehouse environment monitoring. It has temperature range of -4 to 140°F (-20 to 60°C).

Your Price $714.61 USD
Availability 2 to 3 Weeks
Quantity

OMEGA OM-CP-RFPRHTEMP2000A Offers

The OM-CP-RFPRHTEMP2000A is a wireless data logger that measures and records ambient pressure, humidity and temperature. This dynamic data logger is ideal for monitoring weather data, measuring barometric pressure in high-rise buildings or monitoring storage or warehouse environments that contain sensitive material. The OM-CP-RFPRHTEMP2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics.

Features

  • Wireless 2-way communication
  • View data in real-time
  • 5-year battery life
  • Battery life indicator
  • Field upgradeable
  • Audible and led alarm indicators
  • Cumulative alarm delay

Applications

  • Weather data monitoring
  • Barometric pressure measurement in high-rise buildings
  • Storage and warehouse environment monitoring
  • Clinical laboratory monitoring
  • Clean room pressure, humidity and temperature control

OMEGA OM-CP-RFPRHTEMP2000A Specifications

Series OM-CP-RFPRHTEMP2000A Series
Type wireless pressure, humidity and temperature data logger
Configuration Humidity & Temperature Data Logger
Channels 3-CH
Configuration Battery
Configuration LCD
Configuration USB
Configuration Field Upgradeable
Temperature Range -4 to 140°F (-20 to 60°C)
Temperature Resolution 0.018°F (0.01°C)
Temperature Calibrated Accuracy ±0.5°C (±0.9°F) 32 to 122°F (0 to 50°C)
Humidity Range 0 to 95% RH
Humidity Resolution 0.1% RH
Humidity Calibrated Accuracy ±3% RH
Pressure Resolution 0.02 mbar (0.008 inH2O)
Pressure Calibrated Accuracy ±10 mbar (4.0 inH2O)
RF Frequency 2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band ISM band 2.405 to 2.48 GHz (channels 11 through 25) @ 250 kbps data rate
Output Power +0 dBm typical
Reading Rate One reading every second up to one every 24 hours
Memory 10,752 readings per channel
Computer Interface USB to mini USB, 250,000 baud for stand-alone operation or OM-CP-RFC1000-EXT required for wireless operation
Operating Environment -4 to 140°F (-20 to 60°C), 0 to 95% RH non-condensing, 0.002 to 100 psia (0 to 6.89 bar)
Battery Type 9 V lithium battery (included); user replaceable
Battery Life 5 years typical at 15 minute reading rate
Enclosure Material ABS plastic
Pressure Range 250 to 522.42 inH2O (1300 mbar)
Transceiver Sensitivity (OM-CP-RFC1000-EXT) -95dBm typical
Transmission Distance (to other OM-CP-RFC1000-EXTs) OM-CP-RFC1000-EXT:4000' (1220 m) maximum outdoors (line of sight unobstructed);1000' (305 m) maximum indoors (typical urban environment); OM-CP-RFC1000-EXT-EUR:2500' (762 m) maximum outdoors (line of sight unobstructed);700' (213 m) maximum indoors (typical urban environment); OM-CP-RFC1000-IP69K:4000' (1220 m) maximum outdoors (line of sight unobstructed);1000' (305 m) maximum indoors (typical urban environment)
Transmission Distance (to Data Loggers) OM-CP-RFC1000-EXT, OM-CP-RFC1000-EXT-EUR, OM-CP-RFC1000-IP69K:2000' (610 m) maximum outdoors (line of sight unobstructed);500' (152 m) maximum indoors (typical urban environment)
Memory Wrap Around Yes
Start Modes Immediate start and delayed start
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Data Format (Display and Software) Date and time stamped °C, °F, °R, K for the temperature channel, %RH, mg/mL, dew point for the humidity channel and mbar, PSI, inHg, mmHg, atm, Torr, Pa, m, kPa, MPa for the pressure channel.
Time Accuracy ±1 minute/month
Software Windows XP SP3/Vista/7 and 8 (32 and 64-bit)
Alarm User configurable audible, on-screen, email and text (SMS) alarms.
Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.
Audible Alarm Functionality 1 beep per second for reading alarm above/below threshold
Display LCD screen (current reading, minimum, maximum and average statistics)
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm)
Weight 4.9 oz (139 g)

What's included with the OMEGA OM-CP-RFPRHTEMP2000A

  • Omega OM-CP-RFPRHTEMP2000A Wireless Pressure, Humidity and Temperature Data Logger, USB

OMEGA OM-CP-RFPRHTEMP2000A Offers

The OM-CP-RFPRHTEMP2000A is a wireless data logger that measures and records ambient pressure, humidity and temperature. This dynamic data logger is ideal for monitoring weather data, measuring barometric pressure in high-rise buildings or monitoring storage or warehouse environments that contain sensitive material. The OM-CP-RFPRHTEMP2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics.

Features

  • Wireless 2-way communication
  • View data in real-time
  • 5-year battery life
  • Battery life indicator
  • Field upgradeable
  • Audible and led alarm indicators
  • Cumulative alarm delay

Applications

  • Weather data monitoring
  • Barometric pressure measurement in high-rise buildings
  • Storage and warehouse environment monitoring
  • Clinical laboratory monitoring
  • Clean room pressure, humidity and temperature control

OMEGA OM-CP-RFPRHTEMP2000A Specifications

Series OM-CP-RFPRHTEMP2000A Series
Type wireless pressure, humidity and temperature data logger
Configuration Humidity & Temperature Data Logger
Channels 3-CH
Configuration Battery
Configuration LCD
Configuration USB
Configuration Field Upgradeable
Temperature Range -4 to 140°F (-20 to 60°C)
Temperature Resolution 0.018°F (0.01°C)
Temperature Calibrated Accuracy ±0.5°C (±0.9°F) 32 to 122°F (0 to 50°C)
Humidity Range 0 to 95% RH
Humidity Resolution 0.1% RH
Humidity Calibrated Accuracy ±3% RH
Pressure Resolution 0.02 mbar (0.008 inH2O)
Pressure Calibrated Accuracy ±10 mbar (4.0 inH2O)
RF Frequency 2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band ISM band 2.405 to 2.48 GHz (channels 11 through 25) @ 250 kbps data rate
Output Power +0 dBm typical
Reading Rate One reading every second up to one every 24 hours
Memory 10,752 readings per channel
Computer Interface USB to mini USB, 250,000 baud for stand-alone operation or OM-CP-RFC1000-EXT required for wireless operation
Operating Environment -4 to 140°F (-20 to 60°C), 0 to 95% RH non-condensing, 0.002 to 100 psia (0 to 6.89 bar)
Battery Type 9 V lithium battery (included); user replaceable
Battery Life 5 years typical at 15 minute reading rate
Enclosure Material ABS plastic
Pressure Range 250 to 522.42 inH2O (1300 mbar)
Transceiver Sensitivity (OM-CP-RFC1000-EXT) -95dBm typical
Transmission Distance (to other OM-CP-RFC1000-EXTs) OM-CP-RFC1000-EXT:4000' (1220 m) maximum outdoors (line of sight unobstructed);1000' (305 m) maximum indoors (typical urban environment); OM-CP-RFC1000-EXT-EUR:2500' (762 m) maximum outdoors (line of sight unobstructed);700' (213 m) maximum indoors (typical urban environment); OM-CP-RFC1000-IP69K:4000' (1220 m) maximum outdoors (line of sight unobstructed);1000' (305 m) maximum indoors (typical urban environment)
Transmission Distance (to Data Loggers) OM-CP-RFC1000-EXT, OM-CP-RFC1000-EXT-EUR, OM-CP-RFC1000-IP69K:2000' (610 m) maximum outdoors (line of sight unobstructed);500' (152 m) maximum indoors (typical urban environment)
Memory Wrap Around Yes
Start Modes Immediate start and delayed start
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Data Format (Display and Software) Date and time stamped °C, °F, °R, K for the temperature channel, %RH, mg/mL, dew point for the humidity channel and mbar, PSI, inHg, mmHg, atm, Torr, Pa, m, kPa, MPa for the pressure channel.
Time Accuracy ±1 minute/month
Software Windows XP SP3/Vista/7 and 8 (32 and 64-bit)
Alarm User configurable audible, on-screen, email and text (SMS) alarms.
Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.
Audible Alarm Functionality 1 beep per second for reading alarm above/below threshold
Display LCD screen (current reading, minimum, maximum and average statistics)
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm)
Weight 4.9 oz (139 g)

What's included with the OMEGA OM-CP-RFPRHTEMP2000A

  • Omega OM-CP-RFPRHTEMP2000A Wireless Pressure, Humidity and Temperature Data Logger, USB

More OMEGA Products