Omega OM-CP-OCTPRO Programmable Data Logger, 8-channel, universal input, touch screen

Model: OM-CP-OCTPRO

Omega OM-CP-OCTPRO Programmable Data Logger, 8-channel, universal input, touch screen

Model: OM-CP-OCTPRO

Designed for multi-channel measurement and recording, this programmable data logger accepts eight universal input channels. Each channel can be configured for thermocouple, RTD, thermistor, mA, voltage and pulse signals, viewed on a graphical touch screen display. Battery-powered with USB flash-drive offload, it works great for multi-point temperature and process logging.

Designed for multi-channel measurement and recording, this programmable data logger accepts eight universal input channels. Each channel can be configured for thermocouple, RTD, thermistor, mA, voltage and pulse signals, viewed on a graphical touch screen display. Battery-powered with USB flash-drive offload, it works great for multi-point temperature and process logging.

Your Price $1339.62 USD
Availability 2 to 3 Weeks
Quantity

OMEGA OM-CP-OCTPRO Offers

The Omega OM-CP-OCTPRO is a portable, multi-use industrial data logger with eight channels and a user-friendly touchscreen interface. This versatile logger measures and records temperature, current, voltage and pulse simultaneously and displays data in real time. The OM-CP-OCTPRO is compatible for use with many thermocouple, RTD or thermistor probes as well as a number of voltage output sensors, current switches, transmitters and transducers.

Versatility makes OM-CP-OCTPRO the perfect companion for industrial engineers, quality assurance professionals, compliance officers or automotive technicians. The OM-CP-OCTPRO is very easy to use and configure via the built in capacitive touchscreen graphic display.

The OM-CP-OCTPRO is a powerful, independent tool. Unlike many other data loggers, the OM-CP-OCTPRO delivers an all-in-one data collection and monitoring solution that does not require a PC or any downloaded software for operation.

Applications

  • Recording multi-channel temperature, current, voltage and pulse data in industrial process monitoring
  • Verifying thermal profiles with thermocouple, RTD or thermistor probes for quality assurance
  • Documenting environmental and equipment conditions for regulatory compliance audits
  • Capturing sensor data during automotive component and vehicle testing
  • Offloading logged sessions to a USB flash drive for field data collection without a PC

OMEGA OM-CP-OCTPRO Specifications

Touch screen dimensions 5"
Number of channels 8
IP rating IP20
Start modes Immediate Start & Delay Start
Memory 1,000,000 or 5,000,000 readings
Battery type Rechargeable 3.7 V Lithium Ion Battery Pack
Battery life Continuous on-screen sampling: 7-9 hours depending on display setting and reading rate
Stand-by mode: 100 hours
Data format Exported .csv file format, .mtb or both
Time accuracy ±1 minute/month
Operating environment 32°F to +122°F (0°C to +50°C)
0 %RH to 95 %RH non-condensing
Enclosure material Polycarbonate, TPE Protective Boot
Calibration Factory calibration is recommended annually
Current range (0 - 24 mA) -5 mA to 50 mA
Current resolution (0 - 24 mA) 0.0001 mA
Current accuracy (0 - 24 mA) ±0.024 mA (0 to 24 mA)
Current input impedance (0 - 24 mA) 30 Ω
Millivolt range (0 - 100 mV) -100 mV to 2450 mV
Millivolt resolution (0 - 100 mV) 0.0001 mV
Millivolt accuracy (0 - 100 mV) ±0.1 mV (0 to 100 mV)
Millivolt input impedance (0 - 100 mV) 1 GΩ
Millivolt maximum voltage (0 - 100 mV) 3.0 V
Voltage range (0 - 10 V) -0.5 V to 12.0 V
Voltage resolution (0 - 10 V) 0.0001 V
Voltage accuracy (0 - 10 V) ±0.01 V (-0.5 V to 12.0 V)
Voltage input impedance (0 - 10 V) 1 GΩ
Voltage maximum voltage (0 - 10 V) 25 V
Frequency/pulse maximum count 4,000,000,000
Frequency/pulse maximum frequency 25 KHz
Frequency/pulse input signal 0 V to 12 V
Frequency/pulse input impedance 58 KΩ
PT-100 2-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 2-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
PT-100 3-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 3-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
PT-100 4-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 4-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
NTC-1 (2252) range -25°C to +150°C (Probe Dependent) (29,380 Ω to 41.9 Ω)
NTC-1 (2252) resolution 0.01°C
NTC-1 (2252) accuracy ±0.50% FSR (Probe Dependent)
NTC-2 (10K) range -25°C to +150°C (Probe Dependent) (102,900 Ω to 238 Ω)
NTC-2 (10K) resolution 0.01°C
NTC-2 (10K) accuracy ±0.50% FSR (Probe Dependent)
RTD note (all RTD configurations) Temperature Specifications based on ideal 100 Ω PT RTD Compliant with IEC 751(1983) and ITS-90. Accuracy based on 4-wire configuration.
RTD range (all configurations) -200°C to +850°C (Probe Dependent) (18.5 Ω to 390.5 Ω)
Thermocouple J range -200°C to +760°C
Thermocouple J resolution 0.1°C
Thermocouple J accuracy ±0.5°C
Thermocouple K range -270°C to +1370°C
Thermocouple K resolution 0.1°C
Thermocouple K accuracy ±0.5°C
Thermocouple T range -270°C to +400°C
Thermocouple T resolution 0.1°C
Thermocouple T accuracy ±0.5°C
Thermocouple E range -270°C to +980°C
Thermocouple E resolution 0.1°C
Thermocouple E accuracy ±0.5°C
Thermocouple R range -50°C to +1760°C
Thermocouple R resolution 0.5°C
Thermocouple R accuracy ±2.0°C
Thermocouple S range -50°C to +1760°C
Thermocouple S resolution 0.5°C
Thermocouple S accuracy ±2.0°C
Thermocouple N range -270°C to +1300°C
Thermocouple N resolution 0.1°C
Thermocouple N accuracy ±0.5°C
Thermocouple B range 50°C to 1820°C
Thermocouple B resolution 0.5°C
Thermocouple B accuracy ±2.0°C
Thermocouple measurement accuracy At room temperature (25°C ±10°C) after 60 minute warm-up period. Temperature calibrated accuracy is thermocouple dependent. Accuracy does not include Cold Junction Compensation (CJC). CJC error: ±1.5°C
Dimensions 6.65" x 4.40" x 1.41" (168.9 mm x 111.8 mm x 35.8 mm)
Data logger only
Weight 1.3 lbs (20.8 oz)

What's included with the OMEGA OM-CP-OCTPRO

  • 8-Channel Portable Data Logger
  • USB-C Charging Cable

OMEGA OM-CP-OCTPRO Offers

The Omega OM-CP-OCTPRO is a portable, multi-use industrial data logger with eight channels and a user-friendly touchscreen interface. This versatile logger measures and records temperature, current, voltage and pulse simultaneously and displays data in real time. The OM-CP-OCTPRO is compatible for use with many thermocouple, RTD or thermistor probes as well as a number of voltage output sensors, current switches, transmitters and transducers.

Versatility makes OM-CP-OCTPRO the perfect companion for industrial engineers, quality assurance professionals, compliance officers or automotive technicians. The OM-CP-OCTPRO is very easy to use and configure via the built in capacitive touchscreen graphic display.

The OM-CP-OCTPRO is a powerful, independent tool. Unlike many other data loggers, the OM-CP-OCTPRO delivers an all-in-one data collection and monitoring solution that does not require a PC or any downloaded software for operation.

Applications

  • Recording multi-channel temperature, current, voltage and pulse data in industrial process monitoring
  • Verifying thermal profiles with thermocouple, RTD or thermistor probes for quality assurance
  • Documenting environmental and equipment conditions for regulatory compliance audits
  • Capturing sensor data during automotive component and vehicle testing
  • Offloading logged sessions to a USB flash drive for field data collection without a PC

OMEGA OM-CP-OCTPRO Specifications

Touch screen dimensions 5"
Number of channels 8
IP rating IP20
Start modes Immediate Start & Delay Start
Memory 1,000,000 or 5,000,000 readings
Battery type Rechargeable 3.7 V Lithium Ion Battery Pack
Battery life Continuous on-screen sampling: 7-9 hours depending on display setting and reading rate
Stand-by mode: 100 hours
Data format Exported .csv file format, .mtb or both
Time accuracy ±1 minute/month
Operating environment 32°F to +122°F (0°C to +50°C)
0 %RH to 95 %RH non-condensing
Enclosure material Polycarbonate, TPE Protective Boot
Calibration Factory calibration is recommended annually
Current range (0 - 24 mA) -5 mA to 50 mA
Current resolution (0 - 24 mA) 0.0001 mA
Current accuracy (0 - 24 mA) ±0.024 mA (0 to 24 mA)
Current input impedance (0 - 24 mA) 30 Ω
Millivolt range (0 - 100 mV) -100 mV to 2450 mV
Millivolt resolution (0 - 100 mV) 0.0001 mV
Millivolt accuracy (0 - 100 mV) ±0.1 mV (0 to 100 mV)
Millivolt input impedance (0 - 100 mV) 1 GΩ
Millivolt maximum voltage (0 - 100 mV) 3.0 V
Voltage range (0 - 10 V) -0.5 V to 12.0 V
Voltage resolution (0 - 10 V) 0.0001 V
Voltage accuracy (0 - 10 V) ±0.01 V (-0.5 V to 12.0 V)
Voltage input impedance (0 - 10 V) 1 GΩ
Voltage maximum voltage (0 - 10 V) 25 V
Frequency/pulse maximum count 4,000,000,000
Frequency/pulse maximum frequency 25 KHz
Frequency/pulse input signal 0 V to 12 V
Frequency/pulse input impedance 58 KΩ
PT-100 2-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 2-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
PT-100 3-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 3-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
PT-100 4-wire RTD resolution (0.00385 curve) 0.01°C
PT-100 4-wire RTD accuracy (0.00385 curve) ±0.1°C (-200°C to +400°C) (Probe Dependent)
±0.034 Ω (18.5 Ω to 247.1 Ω)
NTC-1 (2252) range -25°C to +150°C (Probe Dependent) (29,380 Ω to 41.9 Ω)
NTC-1 (2252) resolution 0.01°C
NTC-1 (2252) accuracy ±0.50% FSR (Probe Dependent)
NTC-2 (10K) range -25°C to +150°C (Probe Dependent) (102,900 Ω to 238 Ω)
NTC-2 (10K) resolution 0.01°C
NTC-2 (10K) accuracy ±0.50% FSR (Probe Dependent)
RTD note (all RTD configurations) Temperature Specifications based on ideal 100 Ω PT RTD Compliant with IEC 751(1983) and ITS-90. Accuracy based on 4-wire configuration.
RTD range (all configurations) -200°C to +850°C (Probe Dependent) (18.5 Ω to 390.5 Ω)
Thermocouple J range -200°C to +760°C
Thermocouple J resolution 0.1°C
Thermocouple J accuracy ±0.5°C
Thermocouple K range -270°C to +1370°C
Thermocouple K resolution 0.1°C
Thermocouple K accuracy ±0.5°C
Thermocouple T range -270°C to +400°C
Thermocouple T resolution 0.1°C
Thermocouple T accuracy ±0.5°C
Thermocouple E range -270°C to +980°C
Thermocouple E resolution 0.1°C
Thermocouple E accuracy ±0.5°C
Thermocouple R range -50°C to +1760°C
Thermocouple R resolution 0.5°C
Thermocouple R accuracy ±2.0°C
Thermocouple S range -50°C to +1760°C
Thermocouple S resolution 0.5°C
Thermocouple S accuracy ±2.0°C
Thermocouple N range -270°C to +1300°C
Thermocouple N resolution 0.1°C
Thermocouple N accuracy ±0.5°C
Thermocouple B range 50°C to 1820°C
Thermocouple B resolution 0.5°C
Thermocouple B accuracy ±2.0°C
Thermocouple measurement accuracy At room temperature (25°C ±10°C) after 60 minute warm-up period. Temperature calibrated accuracy is thermocouple dependent. Accuracy does not include Cold Junction Compensation (CJC). CJC error: ±1.5°C
Dimensions 6.65" x 4.40" x 1.41" (168.9 mm x 111.8 mm x 35.8 mm)
Data logger only
Weight 1.3 lbs (20.8 oz)

What's included with the OMEGA OM-CP-OCTPRO

  • 8-Channel Portable Data Logger
  • USB-C Charging Cable