Best for transport and environmental monitoring, this portable temperature data logger records to ±0.3°C. It stores 65,520 temperature readings, with configurable alarms and over 4 years of battery life. It also comes with a USB cable, 3 V battery, and software.
Best for transport and environmental monitoring, this portable temperature data logger records to ±0.3°C. It stores 65,520 temperature readings, with configurable alarms and over 4 years of battery life. It also comes with a USB cable, 3 V battery, and software.
The OM-90 Series are portable, battery operated, temperature (OM-91) and temperature/humidity (OM-92) data loggers. The OM-90 Series data loggers offer accurate and repeatable logging for temperature and relative humidity. Temperature is measured to an accuracy of ±0.3°C over the range of 41 to 140°F (5 to 60°C) and ±2.0°C over the full range of -22 to 176°F (-30 to 80°C).
Relative humidity is measured to an accuracy of ±3.0% RH over the 20 to 80% RH range and ±5.0% RH over the 0 to 100% RH range. Both temperature and relative humidity are logged at a user configurable logging rate which is software selectable. These data loggers are ideal for transportation applications where it is necessary to document that the material in-transit has stayed within particular environmental limits.
High/low alarm limits can be set above or below which LED indicators will be activated so that the user can become aware that the desired transportation conditions have been exceeded. Each data logger can be assigned a 16 character name. This can be helpful in applications where multiple data loggers are used and there is a need to distinguish between them (for example based on location).
The data logger includes a very easy to use software application. The application is used for configuration of the logger, extraction of logger data, graphically viewing data, spread sheet analysis of data and saving data to file (typically in comma separated value CSV file format) for third party applications such as Microsoft Excel. The graphical user interface is completely intuitive in terms of configuring new devices and extracting data from a field device.
When the user has multiple devices requiring the same setup then a logger setup from a saved configuration file can be preloaded into the application to help expedite the process and ensure all loggers get setup identically. The application does not require any driver installations to connect to the data logger. Just install the software, run it and then connect the data logger.
Features
Applications
| Temperature range | -22 to 176°F (-30 to 80°C) |
| Temperature resolution | 0.01°C |
| Temperature accuracy | ±0.3°C from 41 to 140°F (5 to 60°C); ±2.0°C over full range |
| Calibration accuracy | ±0.1°C at 25°C ±20°C |
| Memory | 65,520 temperature measurements |
| Start modes | Immediate start on disconnect from PC, delayed (scheduled date/time) or pushbutton start |
| Recording mode | Stop on memory full; last memory location retained on user start/stop |
| Recording interval | 1 sec, 10 sec, 30 sec, 1 minimum, 10 minimum, 30 minimum, 1 hr (software selectable) |
| Real-time logging | Displays real-time data when connected to a PC |
| Real-time clock | Time synced to PC; battery backup; 0.50 sec/day (~3 minutes/year) |
| Alarms | High and low alarms for temperature and humidity; dedicated alarm LED |
| LED indicators | Alarm and status LEDs |
| Device ID | 16 character name |
| Connections | 3' (0.9 m) USB Micro-B to PC cable (included) |
| Battery | 3 V lithium CR2450 included, user replaceable |
| Battery life | Over 4 years while logging |
| Software compatibility | Windows XP/Vista/7/8/10 (32- and 64-bit) |
| Dimensions | 1.38 x 2.36 x 0.6" (53 x 33 x 15 mm) |
| Weight | Net weight: 0.9 oz (25 g) |
| Temperature range | -22 to 176°F (-30 to 80°C) |
| Temperature resolution | 0.01°C |
| Temperature accuracy | ±0.3°C from 41 to 140°F (5 to 60°C); ±2.0°C over full range |
| Calibration accuracy | ±0.1°C at 25°C ±20°C |
| Memory | 65,520 temperature measurements |
| Start modes | Immediate start on disconnect from PC, delayed (scheduled date/time) or pushbutton start |
| Recording mode | Stop on memory full; last memory location retained on user start/stop |
| Recording interval | 1 sec, 10 sec, 30 sec, 1 minimum, 10 minimum, 30 minimum, 1 hr (software selectable) |
| Real-time logging | Displays real-time data when connected to a PC |
| Real-time clock | Time synced to PC; battery backup; 0.50 sec/day (~3 minutes/year) |
| Alarms | High and low alarms for temperature and humidity; dedicated alarm LED |
| LED indicators | Alarm and status LEDs |
| Device ID | 16 character name |
| Connections | 3' (0.9 m) USB Micro-B to PC cable (included) |
| Battery | 3 V lithium CR2450 included, user replaceable |
| Battery life | Over 4 years while logging |
| Software compatibility | Windows XP/Vista/7/8/10 (32- and 64-bit) |
| Dimensions | 1.38 x 2.36 x 0.6" (53 x 33 x 15 mm) |
| Weight | Net weight: 0.9 oz (25 g) |