Image is for reference only, refer to product info for complete details.
This RTD temperature transmitter uses a Pt100 platinum sensing element with M12 connector, rated Class A per IEC 60751 over -58 to 248°F (-50 to 120°C) in a 3 x 13 mm probe. It suits industrial process temperature transmission.
This RTD temperature transmitter uses a Pt100 platinum sensing element with M12 connector, rated Class A per IEC 60751 over -58 to 248°F (-50 to 120°C) in a 3 x 13 mm probe. It suits industrial process temperature transmission.
RTD 100 Ω sensor with built-in transmitter is programmable by a computer. This unique probe is ideal for areas with space limitations where traditional head connections are too large to fit. The M12 thread design offers a secure industrial connection.
Features
Applications
| Series | M12TXSS Series |
| Type | RTD Temperature Transmitter |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -58 to 248°F (-50 to 120°C) |
| Sheath material | 316 SS |
| Connection | M12 Connector |
| Output | 4 to 20 mA (2-wire transmitter) |
| Body | Stainless steel AISI 316L |
| Probe Type | Thermowell AISI 316L SS |
| Diameter | Ø0.1" (3 mm) |
| Diameter (To Order) | 0.118" (3 mm) |
| Probe Length | 0.51" (13 mm) and 0.94" (24 mm) |
| Probe Minimum Bending Radius | Three-times the outer diameter [except the sensing tip which length is 1.2" (30 mm)] |
| Output Connection | M12x1 male |
| Range | -58 to 248°F (-50 to 120°C) |
| Tmax. Electronic | 176°F (80°C) |
| Environment Conditions: Temperature | -40 to 176°F (-40 to 80°C) for plastic body |
| Relative Humidity | 0 to 100% |
| Degree of Protection | IP65 and IP67 in accordance to IEC60529 |
| EMC | In accordance to EN 61326 |
| Accuracy: Transmitter | Maximum of ±0.2°C or ±0.2% of span |
| Accuracy: Sensor | Class A in accordance to IEC751 |
| Temperature Influence [Deviation from 20°C (68°F)] | Maximum of ±0.3°C/77°F (25°C) or ±0.3% of span/77°F (25°C) |
| Supply Voltage Influence | Negligible |
| Response Time | Diameter 0.12" (3 mm) <3.5 seconds, diameter 0.24" (6 mm) <13 seconds (test in water to IEC751-time for reaching 63.2% of instantaneous temperature change) |
| Response Time (90%) | <50 ms |
| Sensor Error Compensation | Over 2 points (maximum 1% of span) |
| Zero Adjustments | Any value between -58 to 122°F (-50 to 50°C) |
| Minimum Span | 122°F (50°C) [if the zero value is set between one of these values: -40°F (-40°C), -4°F (-20°C), 32°F (0°C), 68°F (20°C), 104°F (40°C), the minimum span is 68°F (20°C) rather than 122°F (50°C)] |
| Output Signal | 4 to 20 mA |
| Factory Default | 4 to 20 mA = 32 to 212°F (0 to 100°C) |
| Sensor Break Monitoring | Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action; Factory Setting: 32 to 212°F (0 to 100°C)/sensor break >21 mA (upscale) |
| Sensor Short-Circuit | Fixed to downscale (<3.6 mA) action |
| Permissible Load | 700 @ 24 V DC [RLo= (Vsupply-8,5)/0,020] |
| Isolation In-Out | Non-isolated |
| Power Supply | 8.5 to 32 V DC (polarity protected) |
| Programming | Programmable by a computer; configuration kit required is M12TX-CONFIG-SET |
| Configurable Parameters | Temperature range (-58 to 1472°F (-50 to 800°C)), measurement unit (°C/°F/°K), sensor break monitoring (upscale/downscale), identifying name of the transmitter (16 alphanumeric characters), input sensor error compensation over one or two points |
| Probe dimensions | 0.118 x 0.512" (3 x 13 mm) |
| Series | M12TXSS Series |
| Type | RTD Temperature Transmitter |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -58 to 248°F (-50 to 120°C) |
| Sheath material | 316 SS |
| Connection | M12 Connector |
| Output | 4 to 20 mA (2-wire transmitter) |
| Body | Stainless steel AISI 316L |
| Probe Type | Thermowell AISI 316L SS |
| Diameter | Ø0.1" (3 mm) |
| Diameter (To Order) | 0.118" (3 mm) |
| Probe Length | 0.51" (13 mm) and 0.94" (24 mm) |
| Probe Minimum Bending Radius | Three-times the outer diameter [except the sensing tip which length is 1.2" (30 mm)] |
| Output Connection | M12x1 male |
| Range | -58 to 248°F (-50 to 120°C) |
| Tmax. Electronic | 176°F (80°C) |
| Environment Conditions: Temperature | -40 to 176°F (-40 to 80°C) for plastic body |
| Relative Humidity | 0 to 100% |
| Degree of Protection | IP65 and IP67 in accordance to IEC60529 |
| EMC | In accordance to EN 61326 |
| Accuracy: Transmitter | Maximum of ±0.2°C or ±0.2% of span |
| Accuracy: Sensor | Class A in accordance to IEC751 |
| Temperature Influence [Deviation from 20°C (68°F)] | Maximum of ±0.3°C/77°F (25°C) or ±0.3% of span/77°F (25°C) |
| Supply Voltage Influence | Negligible |
| Response Time | Diameter 0.12" (3 mm) <3.5 seconds, diameter 0.24" (6 mm) <13 seconds (test in water to IEC751-time for reaching 63.2% of instantaneous temperature change) |
| Response Time (90%) | <50 ms |
| Sensor Error Compensation | Over 2 points (maximum 1% of span) |
| Zero Adjustments | Any value between -58 to 122°F (-50 to 50°C) |
| Minimum Span | 122°F (50°C) [if the zero value is set between one of these values: -40°F (-40°C), -4°F (-20°C), 32°F (0°C), 68°F (20°C), 104°F (40°C), the minimum span is 68°F (20°C) rather than 122°F (50°C)] |
| Output Signal | 4 to 20 mA |
| Factory Default | 4 to 20 mA = 32 to 212°F (0 to 100°C) |
| Sensor Break Monitoring | Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action; Factory Setting: 32 to 212°F (0 to 100°C)/sensor break >21 mA (upscale) |
| Sensor Short-Circuit | Fixed to downscale (<3.6 mA) action |
| Permissible Load | 700 @ 24 V DC [RLo= (Vsupply-8,5)/0,020] |
| Isolation In-Out | Non-isolated |
| Power Supply | 8.5 to 32 V DC (polarity protected) |
| Programming | Programmable by a computer; configuration kit required is M12TX-CONFIG-SET |
| Configurable Parameters | Temperature range (-58 to 1472°F (-50 to 800°C)), measurement unit (°C/°F/°K), sensor break monitoring (upscale/downscale), identifying name of the transmitter (16 alphanumeric characters), input sensor error compensation over one or two points |
| Probe dimensions | 0.118 x 0.512" (3 x 13 mm) |