Designed for boiler level measurement and high pressure tank level measurement, this float level transmitter provides NEMA 4X, Liquid, 2" (5.1 cm) NPT Male. It has accuracy of 0.25% span in water.
Designed for boiler level measurement and high pressure tank level measurement, this float level transmitter provides NEMA 4X, Liquid, 2" (5.1 cm) NPT Male. It has accuracy of 0.25% span in water.
The LVR500 Series float level transmitter provides continuous level measurement up to 6.5' (2 m) with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils.
Features
Applications
| Series | LVR500 Series |
| Type | float level transmitter |
| Configuration | NEMA 4X |
| Configuration | Liquid |
| Configuration | 2" (5.1 cm) NPT Male |
| Accuracy | ± 0.25 % |
| Configuration | 200 psi (13.79 bar) |
| Range | 185°F (85°C) |
| Supply voltage | 10 V DC to 30 V DC |
| Output | 4 mA to 20 mA |
| Material | 316 SS |
| Configuration | 16" (40.6 cm) L |
| Accuracy | 0.25% span in water |
| Configuration | None, fixed span |
| Orientation | ±20° from vertical |
| Specific Gravity | 0.55 minimum |
| Supply Voltage | 10 to 30 V DC |
| Loop Resistance | 600 Ω @ 24 V DC |
| Signal Output | 4 to 20 mA, two-wire |
| Process Temperature | -40 to 185°F (-40 to 85°C) |
| Ambient Temperature | -40 to 140°F (-40 to 60°C) |
| Pressure | 200 psi (13.8 bar) |
| Enclosure Rating | NEMA 4X (IP65) |
| Enclosure Material | PP |
| Conduit Entrance | Single, 1/2 NPT |
| Process Mount | 2 NPT |
| Guide-Float Material | 316 SS |
| Classification | General purpose |
| Compliance | CE |
| Process Temp | -40 to 185°F (-40 to 85°C) |
| Ambient Temp | -40 to 140°F (-40 to 60°C) |
| Series | LVR500 Series |
| Type | float level transmitter |
| Configuration | NEMA 4X |
| Configuration | Liquid |
| Configuration | 2" (5.1 cm) NPT Male |
| Accuracy | ± 0.25 % |
| Configuration | 200 psi (13.79 bar) |
| Range | 185°F (85°C) |
| Supply voltage | 10 V DC to 30 V DC |
| Output | 4 mA to 20 mA |
| Material | 316 SS |
| Configuration | 16" (40.6 cm) L |
| Accuracy | 0.25% span in water |
| Configuration | None, fixed span |
| Orientation | ±20° from vertical |
| Specific Gravity | 0.55 minimum |
| Supply Voltage | 10 to 30 V DC |
| Loop Resistance | 600 Ω @ 24 V DC |
| Signal Output | 4 to 20 mA, two-wire |
| Process Temperature | -40 to 185°F (-40 to 85°C) |
| Ambient Temperature | -40 to 140°F (-40 to 60°C) |
| Pressure | 200 psi (13.8 bar) |
| Enclosure Rating | NEMA 4X (IP65) |
| Enclosure Material | PP |
| Conduit Entrance | Single, 1/2 NPT |
| Process Mount | 2 NPT |
| Guide-Float Material | 316 SS |
| Classification | General purpose |
| Compliance | CE |
| Process Temp | -40 to 185°F (-40 to 85°C) |
| Ambient Temp | -40 to 140°F (-40 to 60°C) |