Designed for portable temperature logging, this handheld thermocouple data logger records up to 14,000 readings from thermocouple inputs (Type J, K, T, E, R, S and N). It shows readings on a 5-digit LCD and transfers data over USB, with minimum/maximum and hold functions. Battery-powered with auto power-off, it works great for field and laboratory temperature logging.
Designed for portable temperature logging, this handheld thermocouple data logger records up to 14,000 readings from thermocouple inputs (Type J, K, T, E, R, S and N). It shows readings on a 5-digit LCD and transfers data over USB, with minimum/maximum and hold functions. Battery-powered with auto power-off, it works great for field and laboratory temperature logging.
The HH147AU is a 2-channel thermometer with data logging capabilities and a capacity of 14,000 records.
Features
Applications
| K Type range | -328 to 2501°F (-200 to 1372°C) |
| J Type range | -346 to 2192°F (-210 to 1200°C) |
| T Type range | -418 to 752°F (-250 to 400°C) |
| E Type range | -346 to 1832°F (-210 to 1000°C) |
| R/S Type range | 32 to 3212°F (0 to 1767°C) |
| N Type range | -238 to 2372°F (-150 to 1300°C) |
| Resolution, K / J / T / E / N Type | 0.1 |
| Resolution, R/S Type | 1 |
| Accuracy, K / J / T / E / N Type | ±(0.05% rdg, 0.7°C/1.4°F) -250 to -100°C (-418 to -148°F); ±(0.05% rdg, 0.6°C/1°F) -100 to 1372°C (-148 to 2501°F) |
| Accuracy, R/S Type | ±(0.05% rdg, 2°C/4°F) 0 to 1767°C (32 to 3212°F) |
| Temperature coefficient | 0.01% 0.03°C of read value/°C (0.06°F/°F) outside 18 to 28°C (64 to 82°F) specified range [Under -100°C (-148°F): 0.04% of read value added to K, J, T, E, and 0.08% read value added to N] |
| Temperature scale | ITS-90 |
| Accuracy ambient | 18 to 28°C (64 to 82°F) |
| Battery life | Approximately 100 hours |
| Operation and storage temperature and humidity | 32 to 122°F (0 to 50°C), < 80% RH |
| USB PC serial interface | Windows XP/7/8/10 |
| Dimensions | 6.10 x 2.20 x 1.57" (155 L x 56 W x 40 D mm) |
| Weight | Approximately 0.37 lb (170 g) |
| K Type range | -328 to 2501°F (-200 to 1372°C) |
| J Type range | -346 to 2192°F (-210 to 1200°C) |
| T Type range | -418 to 752°F (-250 to 400°C) |
| E Type range | -346 to 1832°F (-210 to 1000°C) |
| R/S Type range | 32 to 3212°F (0 to 1767°C) |
| N Type range | -238 to 2372°F (-150 to 1300°C) |
| Resolution, K / J / T / E / N Type | 0.1 |
| Resolution, R/S Type | 1 |
| Accuracy, K / J / T / E / N Type | ±(0.05% rdg, 0.7°C/1.4°F) -250 to -100°C (-418 to -148°F); ±(0.05% rdg, 0.6°C/1°F) -100 to 1372°C (-148 to 2501°F) |
| Accuracy, R/S Type | ±(0.05% rdg, 2°C/4°F) 0 to 1767°C (32 to 3212°F) |
| Temperature coefficient | 0.01% 0.03°C of read value/°C (0.06°F/°F) outside 18 to 28°C (64 to 82°F) specified range [Under -100°C (-148°F): 0.04% of read value added to K, J, T, E, and 0.08% read value added to N] |
| Temperature scale | ITS-90 |
| Accuracy ambient | 18 to 28°C (64 to 82°F) |
| Battery life | Approximately 100 hours |
| Operation and storage temperature and humidity | 32 to 122°F (0 to 50°C), < 80% RH |
| USB PC serial interface | Windows XP/7/8/10 |
| Dimensions | 6.10 x 2.20 x 1.57" (155 L x 56 W x 40 D mm) |
| Weight | Approximately 0.37 lb (170 g) |