Omega FMA904A-MA Hot-Wire Air Velocity Transmitter, 0 to 5000 FPM, 1/4 dia x 12", Fixed Probe

Model: FMA904A-MA

Omega FMA904A-MA Hot-Wire Air Velocity Transmitter, 0 to 5000 FPM, 1/4 dia x 12", Fixed Probe

Model: FMA904A-MA

Designed for air velocity measurement, this hot-wire air velocity transmitter reads 0 to 5000 FPM (0 to 25.4 m/s) with an accuracy of ±2% of full scale or ±15 FPM, whichever is greater. It uses a fixed 1/4" (6.35 mm) dia x 12" (30.5 cm) sensor and provides a 4 to 20 mA output and an SPST alarm relay on 15 to 24 V DC. Great for HVAC duct and airflow monitoring.

Designed for air velocity measurement, this hot-wire air velocity transmitter reads 0 to 5000 FPM (0 to 25.4 m/s) with an accuracy of ±2% of full scale or ±15 FPM, whichever is greater. It uses a fixed 1/4" (6.35 mm) dia x 12" (30.5 cm) sensor and provides a 4 to 20 mA output and an SPST alarm relay on 15 to 24 V DC. Great for HVAC duct and airflow monitoring.

Your Price $764.87 USD
Availability 2 to 3 Weeks
Quantity

OMEGA FMA904A-MA Offers

The FMA900A Series measures air velocity and provides an analog output proportional to the air flow, and one SPST relay contact closure for high alarm operation. The alarm set point is adjustable from 0 to 100% of the air flow range. The unit comes with one green power LED, and one red LED for alarm indication.

The FMA900A Series are used in research and development labs, HVAC applications, exhaust/ventilation hoods and other manufacturing processes. The sensor probe comes in two configurations, fixed mount 12" (305 mm) probe and remote 12" (305 mm) probe with 15' (4.5 m) of shielded cable.

Features

  • Air velocity range 0 to 5000 FPM (0 to 25.4 m/sec)
  • 2% full scale accuracy
  • Hot wire air velocity sensor design
  • Two sensor probe configurations: fixed mount and remote probe
  • 250 msec response time
  • Adjustable high alarm set point
  • One SPST relay contact closure with red LED indication
  • Linear 0 to 5 Vdc or 4 to 20 mA analog output
  • Used in HVAC monitoring, exhaust/ventilation hoods

Applications

  • Monitoring air velocity in HVAC duct systems
  • Measuring airflow in exhaust and ventilation hoods
  • Air velocity testing in research and development labs
  • Monitoring air flow in manufacturing processes
  • Verifying exhaust flow for fume hood safety

OMEGA FMA904A-MA Specifications

Accuracy 2% of FS or 15 FPM, whichever larger
High alarm set point Adjustable from 0 to 100% of air flow range
Alarm indication Red LED on the back plate
Alarm deadband 5% of FS
Relay One 12 V SPST NO relay
Contact rating 10 A @ 24 Vdc
Power indicator Green LED
Power 15 Vdc to 24 Vdc @ 200 mA
Operating ambient temperature, sensor probe -40°F to 199°F (-40°C to 93°C)
Operating ambient temperature, electronic case 32°F to 122°F (0°C to 50°C)
NIST traceable Up to 8500 FPM
Air velocity range 0 to 5000 FPM (0 to 25.4 m/sec)
Probe configuration Fixed probe
Analog output 4 to 20 mA
Dimensions 3.5 x 2 x 1.25" (89 x 51 x 32 mm) (H x W x D)
Air velocity probe: 1/4" OD x 12" L (6 mm OD x 305 mm L)
Weight 5.6 oz (160 g)

What's included with the OMEGA FMA904A-MA

  • Air Velocity Transmitter
  • 12" (305 mm) Long Sensor Probe or Remote Probe
  • Operator's Manual

OMEGA FMA904A-MA Offers

The FMA900A Series measures air velocity and provides an analog output proportional to the air flow, and one SPST relay contact closure for high alarm operation. The alarm set point is adjustable from 0 to 100% of the air flow range. The unit comes with one green power LED, and one red LED for alarm indication.

The FMA900A Series are used in research and development labs, HVAC applications, exhaust/ventilation hoods and other manufacturing processes. The sensor probe comes in two configurations, fixed mount 12" (305 mm) probe and remote 12" (305 mm) probe with 15' (4.5 m) of shielded cable.

Features

  • Air velocity range 0 to 5000 FPM (0 to 25.4 m/sec)
  • 2% full scale accuracy
  • Hot wire air velocity sensor design
  • Two sensor probe configurations: fixed mount and remote probe
  • 250 msec response time
  • Adjustable high alarm set point
  • One SPST relay contact closure with red LED indication
  • Linear 0 to 5 Vdc or 4 to 20 mA analog output
  • Used in HVAC monitoring, exhaust/ventilation hoods

Applications

  • Monitoring air velocity in HVAC duct systems
  • Measuring airflow in exhaust and ventilation hoods
  • Air velocity testing in research and development labs
  • Monitoring air flow in manufacturing processes
  • Verifying exhaust flow for fume hood safety

OMEGA FMA904A-MA Specifications

Accuracy 2% of FS or 15 FPM, whichever larger
High alarm set point Adjustable from 0 to 100% of air flow range
Alarm indication Red LED on the back plate
Alarm deadband 5% of FS
Relay One 12 V SPST NO relay
Contact rating 10 A @ 24 Vdc
Power indicator Green LED
Power 15 Vdc to 24 Vdc @ 200 mA
Operating ambient temperature, sensor probe -40°F to 199°F (-40°C to 93°C)
Operating ambient temperature, electronic case 32°F to 122°F (0°C to 50°C)
NIST traceable Up to 8500 FPM
Air velocity range 0 to 5000 FPM (0 to 25.4 m/sec)
Probe configuration Fixed probe
Analog output 4 to 20 mA
Dimensions 3.5 x 2 x 1.25" (89 x 51 x 32 mm) (H x W x D)
Air velocity probe: 1/4" OD x 12" L (6 mm OD x 305 mm L)
Weight 5.6 oz (160 g)

What's included with the OMEGA FMA904A-MA

  • Air Velocity Transmitter
  • 12" (305 mm) Long Sensor Probe or Remote Probe
  • Operator's Manual