Configured for AC/DC Supply, Transmitter I/P, AC Current/Voltage I/P & Process O/P Class, this DIN rail transmitter suits the 0...5 a ac range makes it possible to accurately measure a typical current transformer and converts narrow ac current / voltage inputs to wide bipolar or unipolar outputs.
Configured for AC/DC Supply, Transmitter I/P, AC Current/Voltage I/P & Process O/P Class, this DIN rail transmitter suits the 0...5 a ac range makes it possible to accurately measure a typical current transformer and converts narrow ac current / voltage inputs to wide bipolar or unipolar outputs.
Universal AC/DC transmitter that measures AC current and voltage signals and converts these into uni-/bipolar DC current and voltage signals. Outputs passive or active current signals, with programming, process monitoring and diagnostics via DRSL-DISPLAY.
Features
Applications
| Series | DRST-AC Series |
| Operating temperature | -4°F to 140°F (-20°C to 60°C) |
| Type | DIN rail transmitter |
| Storage temperature | -4°F to 185°F (-20°C to 85°C) |
| Supply voltage | AC/DC Supply |
| Calibration temperature | 68°F to 82°F (20°C to 28°C) |
| Input | Transmitter I/P |
| Relative humidity | < 95% RH (non-cond.) |
| Input | AC Current/Voltage I/P & Process O/P Class |
| Protection degree | IP20 |
| Supply voltage, universal | 21.6...253 V AC, 50...60 Hz or 19.2...300 V DC |
| Installation | Pollution degree 2 & measurement / overvoltage category II |
| Maximum required power | ≤ 1.8 W nominal |
| DIN rail type | DIN EN 60715 - 35 mm |
| Maximum power dissipation | ≤ 2.5 W |
| Wire size | 0.0002 to 0.0032 sq inch (0.13 to 2.08 mm2) / AWG 26 to 14 stranded wire |
| Isolation voltage - test | 2.3 kV AC |
| Screw terminal torque | 0.5 Nm |
| Isolation voltage - working | 250 V AC (reinforced) / 500 V AC (basic) |
| Supply voltage, universal | 21.6 to 253 VAC, 50 to 60 Hz or 19.2 to 300 Vdc |
| Programming | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Max. required power | <= 1.8 W nom. |
| Signal dynamics, input / output | 20 bit / 18 bit |
| Max. power dissipation | <= 2.5 W |
| Signal/noise ratio | > 60 dB |
| Isolation voltage - test | 2.3 kVac |
| Response time (0...90%, 100...10%) | < 0.75 s |
| Isolation voltage - working | 250 Vac (reinforced) / 500 Vac (basic) |
| Absolute accuracy (all input types) | ≤ ±0.3% of span |
| Programming | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| Signal dynamics, input / output | 20 bit / 18 bit |
| EMC - immunity influence | < ±0.5% of span |
| Signal/noise ratio | > 60 dB |
| Protection degree | IP20 |
| Response time (0 to 90%, 100 to 10%) | < 0.75 s |
| DIN rail type | DIN EN DIN EN 60715, 1.4" (35 mm) |
| Output referred common mode rejection ratio | 0.02 ppm / VHz |
| Wire size | 0.13...2.08 mm2 / AWG 26...14 stranded wire |
| Current input signal range | 0 to 5 AAC / 40 to 400 Hz |
| Screw terminal torque | 4.43 in-lb (0.5 Nm) |
| Current input maximum input limit | 6.00 AAC @ 104°F (40°C) |
| Operating temperature | -4 to 140°F (-20 to 60°C) |
| Current input programmable measurement ranges | 0 to 0.5, 0 to 1, 0 to 2.5 & 0 to 5 AAC |
| Storage temperature | -4 to 185°F (-20 to 85°C) |
| Current input custom configurable signal range | 0 to 5 AAC / 40 to 400 Hz |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Current input min. span | 0.5 AAC |
| Relative humidity | < 95% RH (non-condensing) |
| Current input resistance | Nom. < 0.07 Ohm |
| Product Type | Universal AC/DC transmitter (measures AC current and voltage signals, converts to uni-/bipolar DC current and voltage signals) |
| Voltage input signal range | 0 to 300 VAC / 40 to 400 Hz |
| Max. Required Power | ≤ 1.8 W nom. |
| Voltage input programmable measurement ranges | 0 to 0.5, 0 to 1, 0 to 2.83, 0 to 5, 0 to 120, 0 to 230 & 0 to 300 VAC |
| Max. Power Dissipation | ≤ 2.5 W |
| Voltage input custom configurable signal range | 0 to 300 VAC / 40 to 400 Hz |
| Output Referred Common Mode Rejection Ratio | 0.02 ppm / VHz |
| Voltage input min. span | 0.5 VAC |
| Basic Accuracy, Current | 1.5 mA; 50 μA/°C |
| Voltage input resistance | Nom. 3 MOhm || 100 pF |
| Basic Accuracy, Voltage | 1.5 mVAC; 50 μVAC/°C |
| Configurable input limit, low VOLT | 0 VAC to 'Minimum selected input' |
| Extended EMC Immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Configurable input limit, low CURR | 0 AAC to 'Minimum selected input' |
| Current Input Signal Range | 0...5 AAC / 40...400 Hz |
| Configurable input limit, high VOLT | 'Maximum selected input' to 300 VAC |
| Current Input Maximum Input Limit | 6.00 AAC @ 104°F (40°C) |
| Configurable input limit, high CURR | 'Maximum selected input' to 5 AAC |
| Current Input Programmable Measurement Ranges | 0...0.5, 0…1, 0…2.5 & 0...5 AAC |
| Hysteresis | 0.5% of 'Max. output' |
| Current Input Custom Configurable Signal Range | 0….5 AAC / 40...400 Hz |
| Error detection release delay | < 2.5 s |
| Current Input Min. Span | 0.5 AAC |
| EMC - immunity influence | < ±0.5% of span |
| Current Input Resistance | Nom. < 0.07 Ω |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Voltage Input Signal Range | 0...300 VAC / 40...400 Hz |
| Absolute accuracy, all input types | <= ±0.3% of span |
| Voltage Input Programmable Measurement Ranges | 0...0.5, 0...1, 0...2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
| Temperature coefficient, all input types | <= ±0.01% of span / °C |
| Voltage Input Custom Configurable Signal Range | 0...300 VAC / 40...400 Hz |
| Basic accuracy, current | 1.5 mA |
| Voltage Input Min. Span | 0.5 VAC |
| Temperature coefficient, current | 50 µA / °C |
| Voltage Input Resistance | Nom. 3 MΩ || 100 pF |
| Basic accuracy, voltage | 1.5 mVAC |
| Configurable Input Limits Hysteresis | 0.5% of 'Max. output' |
| Temperature coefficient, voltage | 50 µVAC / °C |
| Error Detection Release Delay | < 2.5 s |
| Active mA programmable ranges | 0 to 20, 4 to 20, S4 to 20, ±10 and ±20 mA, Direct or Inverted action |
| Active Unipolar and Bipolar mA Programmable Ranges | 0...20, 4...20, S4...20, ±10 and ±20 mA |
| Active mA V-curve function, 100-0-100% | 20-0-20 mA |
| Current Output Load | ≤ 800 Ω |
| Active mA load | <= 800 Ohm |
| Passive 2-Wire mA Programmable Ranges | 0...20 and 4...20 mA |
| Passive 2-wire mA programmable ranges | 0 to 20 and 4 to 20 mA, Direct or Inverted action |
| External 2-Wire Loop Supply | 3.5...30 V |
| Passive 2-wire mA V-curve function, 100-0-100% | 20-0-20 mA |
| Current Signal Range | 0...23 mA (unipolar) / -23...+23 mA (bipolar) |
| External 2-wire loop supply | 3.5 to 30 V |
| Current Limit | ≤ 28 mA (unipolar) / ±28 mA (bipolar) |
| Current output signal range | 0 to 23 mA (unipolar) / -23 to +23 mA (bipolar) |
| Current Output Load Stability | ≤ 0.001% of span / 100 Ω |
| Current output current limit | <= 28 mA (unipolar) / ±28 mA (bipolar) |
| Current Output Response Time, Programmable | 0.0...60.0 s |
| Current output load stability | <= 0.001% of span / 100 Ohm |
| Voltage Output Programmable Ranges | 0/0.2...1, 0/1...5, 0/2...10, ±1, ±5 and ±10 V |
| Current output response time, programmable | 0.0 to 60.0 s |
| Voltage Output Load, Min | > 500 kΩ |
| Voltage output programmable ranges | 0/0.2 to 1, 0/1 to 5, 0/2 to 10, ±1, ±5 and ±10 V, Direct or Inverted action |
| Voltage Output Response Time, Programmable | 0.0...60.0 s |
| Voltage output V-curve function, 100-0-100% | 1-0-1 V, 5-0-5 V and 10-0-10 V |
| Installation | Pollution degree 2 & measurement / overvoltage category II |
| Voltage output load, min | > 500 kOhm |
| Authority Requirements | EMC 2014/30/EU; LVD 2014/35/EU; RoHS 2011/65/EU |
| Voltage output response time, programmable | 0.0 to 60.0 s |
| Approvals | c UL us, Standard for Safety UL 508 / C22.2 No. 14; UL file number E248256 |
| EMC | 2014/30/EU |
| Dimensions (H x W x D) | 4.29 x 0.93 x 4.09" (109 x 23.5 x 104 mm) |
| LVD | 2014/35/EU |
| Dimensions (H x W x D) w/DRSL-DISPLAY/DRST-CM | 109 x 23.5 x 116 / 5.16" (131 mm) |
| RoHS | 2011/65/EU |
| Weight approx. | 8.82 oz (250 g) |
| Approvals | c UL us, Standard for Safety, UL 508 / C22.2 No. 14 |
| Weight incl. DRSL-DISPLAY/DRST-CM (approx.) | 10.05 oz (285 g) / 12.35 oz (350 g) |
| UL file number | E248256 |
| Dimensions | 4.29" x 0.93" x 4.09" (109 x 23.5 x 104 mm) with DRSL-DISPLAY/DRST-CM: 4.29" x 0.93" x 4.57"/5.16" (109 x 23.5 x 116/131 mm) |
| Weight | approx. 8.8 oz (250 g) incl. DRSL-DISPLAY/DRST-CM (approx.): 10.1 oz/12.3 oz (285 g/350 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-AC DIN Rail Transmitter, AC current/voltage input, process output.
| Series | DRST-AC Series |
| Operating temperature | -4°F to 140°F (-20°C to 60°C) |
| Type | DIN rail transmitter |
| Storage temperature | -4°F to 185°F (-20°C to 85°C) |
| Supply voltage | AC/DC Supply |
| Calibration temperature | 68°F to 82°F (20°C to 28°C) |
| Input | Transmitter I/P |
| Relative humidity | < 95% RH (non-cond.) |
| Input | AC Current/Voltage I/P & Process O/P Class |
| Protection degree | IP20 |
| Supply voltage, universal | 21.6...253 V AC, 50...60 Hz or 19.2...300 V DC |
| Installation | Pollution degree 2 & measurement / overvoltage category II |
| Maximum required power | ≤ 1.8 W nominal |
| DIN rail type | DIN EN 60715 - 35 mm |
| Maximum power dissipation | ≤ 2.5 W |
| Wire size | 0.0002 to 0.0032 sq inch (0.13 to 2.08 mm2) / AWG 26 to 14 stranded wire |
| Isolation voltage - test | 2.3 kV AC |
| Screw terminal torque | 0.5 Nm |
| Isolation voltage - working | 250 V AC (reinforced) / 500 V AC (basic) |
| Supply voltage, universal | 21.6 to 253 VAC, 50 to 60 Hz or 19.2 to 300 Vdc |
| Programming | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Max. required power | <= 1.8 W nom. |
| Signal dynamics, input / output | 20 bit / 18 bit |
| Max. power dissipation | <= 2.5 W |
| Signal/noise ratio | > 60 dB |
| Isolation voltage - test | 2.3 kVac |
| Response time (0...90%, 100...10%) | < 0.75 s |
| Isolation voltage - working | 250 Vac (reinforced) / 500 Vac (basic) |
| Absolute accuracy (all input types) | ≤ ±0.3% of span |
| Programming | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| Signal dynamics, input / output | 20 bit / 18 bit |
| EMC - immunity influence | < ±0.5% of span |
| Signal/noise ratio | > 60 dB |
| Protection degree | IP20 |
| Response time (0 to 90%, 100 to 10%) | < 0.75 s |
| DIN rail type | DIN EN DIN EN 60715, 1.4" (35 mm) |
| Output referred common mode rejection ratio | 0.02 ppm / VHz |
| Wire size | 0.13...2.08 mm2 / AWG 26...14 stranded wire |
| Current input signal range | 0 to 5 AAC / 40 to 400 Hz |
| Screw terminal torque | 4.43 in-lb (0.5 Nm) |
| Current input maximum input limit | 6.00 AAC @ 104°F (40°C) |
| Operating temperature | -4 to 140°F (-20 to 60°C) |
| Current input programmable measurement ranges | 0 to 0.5, 0 to 1, 0 to 2.5 & 0 to 5 AAC |
| Storage temperature | -4 to 185°F (-20 to 85°C) |
| Current input custom configurable signal range | 0 to 5 AAC / 40 to 400 Hz |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Current input min. span | 0.5 AAC |
| Relative humidity | < 95% RH (non-condensing) |
| Current input resistance | Nom. < 0.07 Ohm |
| Product Type | Universal AC/DC transmitter (measures AC current and voltage signals, converts to uni-/bipolar DC current and voltage signals) |
| Voltage input signal range | 0 to 300 VAC / 40 to 400 Hz |
| Max. Required Power | ≤ 1.8 W nom. |
| Voltage input programmable measurement ranges | 0 to 0.5, 0 to 1, 0 to 2.83, 0 to 5, 0 to 120, 0 to 230 & 0 to 300 VAC |
| Max. Power Dissipation | ≤ 2.5 W |
| Voltage input custom configurable signal range | 0 to 300 VAC / 40 to 400 Hz |
| Output Referred Common Mode Rejection Ratio | 0.02 ppm / VHz |
| Voltage input min. span | 0.5 VAC |
| Basic Accuracy, Current | 1.5 mA; 50 μA/°C |
| Voltage input resistance | Nom. 3 MOhm || 100 pF |
| Basic Accuracy, Voltage | 1.5 mVAC; 50 μVAC/°C |
| Configurable input limit, low VOLT | 0 VAC to 'Minimum selected input' |
| Extended EMC Immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Configurable input limit, low CURR | 0 AAC to 'Minimum selected input' |
| Current Input Signal Range | 0...5 AAC / 40...400 Hz |
| Configurable input limit, high VOLT | 'Maximum selected input' to 300 VAC |
| Current Input Maximum Input Limit | 6.00 AAC @ 104°F (40°C) |
| Configurable input limit, high CURR | 'Maximum selected input' to 5 AAC |
| Current Input Programmable Measurement Ranges | 0...0.5, 0…1, 0…2.5 & 0...5 AAC |
| Hysteresis | 0.5% of 'Max. output' |
| Current Input Custom Configurable Signal Range | 0….5 AAC / 40...400 Hz |
| Error detection release delay | < 2.5 s |
| Current Input Min. Span | 0.5 AAC |
| EMC - immunity influence | < ±0.5% of span |
| Current Input Resistance | Nom. < 0.07 Ω |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| Voltage Input Signal Range | 0...300 VAC / 40...400 Hz |
| Absolute accuracy, all input types | <= ±0.3% of span |
| Voltage Input Programmable Measurement Ranges | 0...0.5, 0...1, 0...2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
| Temperature coefficient, all input types | <= ±0.01% of span / °C |
| Voltage Input Custom Configurable Signal Range | 0...300 VAC / 40...400 Hz |
| Basic accuracy, current | 1.5 mA |
| Voltage Input Min. Span | 0.5 VAC |
| Temperature coefficient, current | 50 µA / °C |
| Voltage Input Resistance | Nom. 3 MΩ || 100 pF |
| Basic accuracy, voltage | 1.5 mVAC |
| Configurable Input Limits Hysteresis | 0.5% of 'Max. output' |
| Temperature coefficient, voltage | 50 µVAC / °C |
| Error Detection Release Delay | < 2.5 s |
| Active mA programmable ranges | 0 to 20, 4 to 20, S4 to 20, ±10 and ±20 mA, Direct or Inverted action |
| Active Unipolar and Bipolar mA Programmable Ranges | 0...20, 4...20, S4...20, ±10 and ±20 mA |
| Active mA V-curve function, 100-0-100% | 20-0-20 mA |
| Current Output Load | ≤ 800 Ω |
| Active mA load | <= 800 Ohm |
| Passive 2-Wire mA Programmable Ranges | 0...20 and 4...20 mA |
| Passive 2-wire mA programmable ranges | 0 to 20 and 4 to 20 mA, Direct or Inverted action |
| External 2-Wire Loop Supply | 3.5...30 V |
| Passive 2-wire mA V-curve function, 100-0-100% | 20-0-20 mA |
| Current Signal Range | 0...23 mA (unipolar) / -23...+23 mA (bipolar) |
| External 2-wire loop supply | 3.5 to 30 V |
| Current Limit | ≤ 28 mA (unipolar) / ±28 mA (bipolar) |
| Current output signal range | 0 to 23 mA (unipolar) / -23 to +23 mA (bipolar) |
| Current Output Load Stability | ≤ 0.001% of span / 100 Ω |
| Current output current limit | <= 28 mA (unipolar) / ±28 mA (bipolar) |
| Current Output Response Time, Programmable | 0.0...60.0 s |
| Current output load stability | <= 0.001% of span / 100 Ohm |
| Voltage Output Programmable Ranges | 0/0.2...1, 0/1...5, 0/2...10, ±1, ±5 and ±10 V |
| Current output response time, programmable | 0.0 to 60.0 s |
| Voltage Output Load, Min | > 500 kΩ |
| Voltage output programmable ranges | 0/0.2 to 1, 0/1 to 5, 0/2 to 10, ±1, ±5 and ±10 V, Direct or Inverted action |
| Voltage Output Response Time, Programmable | 0.0...60.0 s |
| Voltage output V-curve function, 100-0-100% | 1-0-1 V, 5-0-5 V and 10-0-10 V |
| Installation | Pollution degree 2 & measurement / overvoltage category II |
| Voltage output load, min | > 500 kOhm |
| Authority Requirements | EMC 2014/30/EU; LVD 2014/35/EU; RoHS 2011/65/EU |
| Voltage output response time, programmable | 0.0 to 60.0 s |
| Approvals | c UL us, Standard for Safety UL 508 / C22.2 No. 14; UL file number E248256 |
| EMC | 2014/30/EU |
| Dimensions (H x W x D) | 4.29 x 0.93 x 4.09" (109 x 23.5 x 104 mm) |
| LVD | 2014/35/EU |
| Dimensions (H x W x D) w/DRSL-DISPLAY/DRST-CM | 109 x 23.5 x 116 / 5.16" (131 mm) |
| RoHS | 2011/65/EU |
| Weight approx. | 8.82 oz (250 g) |
| Approvals | c UL us, Standard for Safety, UL 508 / C22.2 No. 14 |
| Weight incl. DRSL-DISPLAY/DRST-CM (approx.) | 10.05 oz (285 g) / 12.35 oz (350 g) |
| UL file number | E248256 |
| Dimensions | 4.29" x 0.93" x 4.09" (109 x 23.5 x 104 mm) with DRSL-DISPLAY/DRST-CM: 4.29" x 0.93" x 4.57"/5.16" (109 x 23.5 x 116/131 mm) |
| Weight | approx. 8.8 oz (250 g) incl. DRSL-DISPLAY/DRST-CM (approx.): 10.1 oz/12.3 oz (285 g/350 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-AC DIN Rail Transmitter, AC current/voltage input, process output.