Omega CWM Series Constant-Wattage Heating Cable, 120 V AC, 12 W/ft

Model: CWM12-1CT

Omega CWM Series Constant-Wattage Heating Cable, 120 V AC, 12 W/ft

Model: CWM12-1CT

This heating cable is configured for Constant Wattage, FEP Overcoat & Tinned Copper Overbraid, 12 W/ft Density. It suits pipe tracing requiring higher temperatures for process maintenance and process temperature maintenance.

This heating cable is configured for Constant Wattage, FEP Overcoat & Tinned Copper Overbraid, 12 W/ft Density. It suits pipe tracing requiring higher temperatures for process maintenance and process temperature maintenance.

Your Price $31.83 USD
Availability 2 to 3 Weeks
Quantity

OMEGA CWM12-1CT Offers

OMEGALUX CWM (constant wattage medium temperature) heating cable is ideal for pipe tracing situations that require higher temperatures for process maintenance as well as freeze protection. No matter what length of cable is needed, the wattage (or heat) produced by each foot of cable remains unchanged.

Features

  • Constant output
  • Cut to any length
  • Lower installation costs
  • Flexible

Applications

  • Pipe tracing requiring higher temperatures for process maintenance
  • Freeze protection
  • Process temperature maintenance
  • Steam cleaning of process piping
  • Corrosion-resistant heating in chemical environments

OMEGA CWM12-1CT Specifications

Series CWM Series
Type heating cable
Configuration Constant Wattage
Configuration FEP Overcoat & Tinned Copper Overbraid
Configuration 12 W/ft Density
Range 392°F (200°C)
Configuration 25' (7.62 m)
Cable 11/32" (8.7 mm) x 1/4" (6.3 mm) Cable
Supply voltage 120 V AC
Configuration 12 AWG
Configuration CWM Series
Configuration Foot
Wattage 4, 8, 10 and 12 W/ft (13.1, 26.2, 32.8 and 39.4 W/m)
Power 120 V, 240 V and 480 V
Bus Wires 12 AWG copper
Bus Wire Insulation Each bus wire is insulated with an 11 mil FEP jacket.
Maximum Intermittent Exposure Temperature/Power-Off 392°F (200°C)
Steam Cleaning CWM can withstand 392°F (200°C), 150 psig (10.34 bar) steam purging of process piping when not energized
Minimum Bend Radius 6 times minor diameter
Inner Sheath Insulation jacket that holds the 2 bus wires together and provides the wrapping surface for the nichrome heating wire
Heating Wire Nichrome resistance heating wire
Jacket Flame-retardant FEP insulation jacket (corrosion resistant)
Metal Braid Plated copper braid covering the jacket (positive ground path)
Optional Overjacket FEP fluoropolymer overjacket (add suffix -CT)
Approximate Cable Size 5/16 x 1/5" (8 x 5 mm); CT only: 11/32 x 1/4" (26 x 6 mm)
Minimum Length 25' (7.62 m)
Third-Party Approvals FM Approved

What's included with the OMEGA CWM12-1CT

  • Omega CWM Series Constant-Wattage Heating Cable, 120 V AC, 12 W/ft

OMEGA CWM12-1CT Offers

OMEGALUX CWM (constant wattage medium temperature) heating cable is ideal for pipe tracing situations that require higher temperatures for process maintenance as well as freeze protection. No matter what length of cable is needed, the wattage (or heat) produced by each foot of cable remains unchanged.

Features

  • Constant output
  • Cut to any length
  • Lower installation costs
  • Flexible

Applications

  • Pipe tracing requiring higher temperatures for process maintenance
  • Freeze protection
  • Process temperature maintenance
  • Steam cleaning of process piping
  • Corrosion-resistant heating in chemical environments

OMEGA CWM12-1CT Specifications

Series CWM Series
Type heating cable
Configuration Constant Wattage
Configuration FEP Overcoat & Tinned Copper Overbraid
Configuration 12 W/ft Density
Range 392°F (200°C)
Configuration 25' (7.62 m)
Cable 11/32" (8.7 mm) x 1/4" (6.3 mm) Cable
Supply voltage 120 V AC
Configuration 12 AWG
Configuration CWM Series
Configuration Foot
Wattage 4, 8, 10 and 12 W/ft (13.1, 26.2, 32.8 and 39.4 W/m)
Power 120 V, 240 V and 480 V
Bus Wires 12 AWG copper
Bus Wire Insulation Each bus wire is insulated with an 11 mil FEP jacket.
Maximum Intermittent Exposure Temperature/Power-Off 392°F (200°C)
Steam Cleaning CWM can withstand 392°F (200°C), 150 psig (10.34 bar) steam purging of process piping when not energized
Minimum Bend Radius 6 times minor diameter
Inner Sheath Insulation jacket that holds the 2 bus wires together and provides the wrapping surface for the nichrome heating wire
Heating Wire Nichrome resistance heating wire
Jacket Flame-retardant FEP insulation jacket (corrosion resistant)
Metal Braid Plated copper braid covering the jacket (positive ground path)
Optional Overjacket FEP fluoropolymer overjacket (add suffix -CT)
Approximate Cable Size 5/16 x 1/5" (8 x 5 mm); CT only: 11/32 x 1/4" (26 x 6 mm)
Minimum Length 25' (7.62 m)
Third-Party Approvals FM Approved

What's included with the OMEGA CWM12-1CT

  • Omega CWM Series Constant-Wattage Heating Cable, 120 V AC, 12 W/ft