Designed for closed-loop PID control, this 1/16 DIN controller accepts universal thermocouple, RTD, analog, and strain-gauge inputs and provides a pulsed 10 V driver output for an external solid-state relay. It runs on an AC supply and shows readings on a single 4-digit color LED display. Great for oven, furnace, and extruder temperature regulation.
Designed for closed-loop PID control, this 1/16 DIN controller accepts universal thermocouple, RTD, analog, and strain-gauge inputs and provides a pulsed 10 V driver output for an external solid-state relay. It runs on an AC supply and shows readings on a single 4-digit color LED display. Great for oven, furnace, and extruder temperature regulation.
The OMEGA(R) iSeries is a family of microprocessor-based instruments offered in three true DIN sizes. All of the instruments share the same set-up and configuration menu and method of operation, a tremendous time saver for integration of a large system.
The iSeries family includes extremely accurate digital panel meters "DPi" and single loop PID controllers "CNi" that are simple to configure and use, while providing tremendous versatility and a wealth of powerful features. The CNi Series covers a broad selection of transducer and transmitter inputs with 2 input models.
The strain and process instruments (CNiS models) measure inputs from load cells, pressure transducers, and most any strain gage sensor as well as process voltage and current ranges.
This CNiS model supports 4- and 6-wire bridge communications, ratiometric measurements. The CNiS features fast and easy "in process" calibration/scaling of the signal inputs to any engineering units. This model also features 10-point linearization which allows the user to linearize the signal input from extremely nonlinear transducers of all kinds.
The iSeries can control simple manual operation to ON-OFF and full Autotune PID control. (Selectable preset tune, adaptive tune, PID, PI, PD control modes.) The dual control outputs can be configured for a variety of independent control and alarm applications such as heat/heat, heat/cool, heat/alarm, cool/cool, cool/alarm or alarm/alarm.
The ramp to setpoint feature allows the user to define the rate of rise to setpoint, minimizing thermal shock to the load during start-up.
The iSeries are 1/8, 1/16 and 1/32 DIN controllers featuring the big iSeries color-changing display. The digits are twice the size of typical 1/8 DIN panel meters. The iSeries feature the only LED displays that can be programmed to change color between GREEN, AMBER, and RED.
The iSeries are also available with serial communications. The user can select from the pushbutton menu between RS232, RS422, and RS485, with straightforward ASCII commands or MODBUS.
Features
Applications
| Temperature stability process | 50 ppm/°C |
| NMRR | 60 dB |
| CMRR | 120 dB |
| A/D conversion | Dual slope |
| Reading rate | 3 samples/s |
| Digital filter | Programmable |
| Display | 4-digit 9-segment LED 0.40" (10.2 mm); i32, i16, i16D, i8DV 0.83" (21 mm); i8 0.40" (10.2 mm) and 0.83" (21 mm); i8DH RED, GREEN, and AMBER programmable colors for process variable, setpoint and temperature units |
| Input types | Thermocouple, RTD, analog voltage, analog current |
| Input impedance | 10 MΩ for 100 mV; 1 MΩ for 1 or 10 Vdc |
| Current input | 0 to 20 mA (5 Ω load) |
| Configuration | Single-ended |
| Polarity | Unipolar |
| Step response | 0.7 sec for 99.9% |
| Decimal selection temperature | None, 0.1 |
| Decimal selection process | None, 0.1, 0.01 or 0.001 |
| Setpoint adjustment | -1999 to 9999 counts |
| Span adjustment | 0.001 to 9999 counts |
| Offset adjustment | -1999 to 9999 |
| Strain accuracy | 0.03% reading |
| Strain resolution | 10/1 µV |
| Strain temperature stability | 50 ppm/°C |
| Strain voltage input | 0 to 100 mVdc, -100 mVdc to 1 Vdc, 0 to 10 Vdc |
| Linearization points | Up to 10 |
| Strain excitation (optional in place of communication) | 5 Vdc @ 40 mA; 10 Vdc @ 60 mA |
| Control action | Reverse (heat) or direct (cool) |
| Control modes | Time and amplitude proportional control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti-reset windup, and on/off |
| Rate | 0 to 399.9 s |
| Reset | 0 to 3999 s |
| Cycle time | 1 to 199 s; set to 0 for on/off |
| Gain | 0.5 to 100% of span; setpoints 1 or 2 |
| Damping | 0000 to 0008 |
| Soak | 00.00 to 99.59 (HH:MM), or OFF |
| Ramp to setpoint | 00.00 to 99.59 (HH:MM), or OFF |
| Auto tune | Operator initiated from front panel |
| Relay output | 250 Vac or 30 Vdc @ 3 A (resistive load); configurable for on/off, PID and ramp and soak |
| Output 1 | SPDT, can be configured as alarm 1 output |
| Output 2 | SPDT, can be configured as alarm 2 output |
| SSR output | 20 to 265 Vac @ 0.05 to 0.5 A (resistive load); continuous |
| DC pulse output | Non-isolated; 10 Vdc @ 20 mA |
| Analog output (output 1 only) | Non-isolated, proportional 0 to 10 Vdc or 0 to 20 mA; 500 Ω max |
| Output 3 retransmission current | 10 V max @ 20 mA output |
| Output 3 retransmission voltage | 20 mA max for 0 to 10 V output |
| Ethernet | Standards compliance IEEE 802.3 10 Base-T |
| Supported protocols | TCP/IP, ARP, HTTPGET |
| RS232/RS422/RS485 | Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status |
| RS485 addressing | Addressable from 0 to 199 |
| Connection | Screw terminals |
| Alarm type | Same as output 1 and 2 |
| Alarm operation | High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations |
| Programmable analog output | Non-isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 Ω max (output 1 only); accuracy is ±1% of FS when following conditions are satisfied: input is not scaled below 1% of input FS, analog output is not scaled below 3% of output FS |
| Power | 90 to 240 Vac ±10%, 50 to 400 Hz, 110 to 375 Vdc, equivalent voltage |
| Low voltage power option | 24 Vac, 12 to 36 Vdc for DPi/CNi/DPiS/CNiS; 20 to 36 Vdc for dual display, ethernet and isolated analog output from qualified safety approved source |
| Isolation power to input/output | 2300 Vac per 1 minute test |
| Isolation for low voltage power option | 1500 Vac per 1 minute test |
| Isolation power to relay/SSR output | 2300 Vac per 1 minute test |
| Isolation relay/SSR to relay/SSR output | 2300 Vac per 1 minute test |
| Isolation RS232/485 to input/output | 500 Vac per 1 minute test |
| Environmental conditions all models | 32 to 131°F (0 to 55°C) 90% RH non-condensing |
| Approvals | UL, C-UL, UKCA, CE per EN61010-1:2001, FM (temperature units only) |
| Protection | NEMA 4X/Type 4 (IP65) front bezel |
| Dimensions | 1.89 x 1.89 x 5" (48 H x 48 W x 127 mm D) Panel cutout: 1.772" (45 mm) square, 1/16 DIN |
| Weight | 0.35 lb (159 g) |
| Temperature stability process | 50 ppm/°C |
| NMRR | 60 dB |
| CMRR | 120 dB |
| A/D conversion | Dual slope |
| Reading rate | 3 samples/s |
| Digital filter | Programmable |
| Display | 4-digit 9-segment LED 0.40" (10.2 mm); i32, i16, i16D, i8DV 0.83" (21 mm); i8 0.40" (10.2 mm) and 0.83" (21 mm); i8DH RED, GREEN, and AMBER programmable colors for process variable, setpoint and temperature units |
| Input types | Thermocouple, RTD, analog voltage, analog current |
| Input impedance | 10 MΩ for 100 mV; 1 MΩ for 1 or 10 Vdc |
| Current input | 0 to 20 mA (5 Ω load) |
| Configuration | Single-ended |
| Polarity | Unipolar |
| Step response | 0.7 sec for 99.9% |
| Decimal selection temperature | None, 0.1 |
| Decimal selection process | None, 0.1, 0.01 or 0.001 |
| Setpoint adjustment | -1999 to 9999 counts |
| Span adjustment | 0.001 to 9999 counts |
| Offset adjustment | -1999 to 9999 |
| Strain accuracy | 0.03% reading |
| Strain resolution | 10/1 µV |
| Strain temperature stability | 50 ppm/°C |
| Strain voltage input | 0 to 100 mVdc, -100 mVdc to 1 Vdc, 0 to 10 Vdc |
| Linearization points | Up to 10 |
| Strain excitation (optional in place of communication) | 5 Vdc @ 40 mA; 10 Vdc @ 60 mA |
| Control action | Reverse (heat) or direct (cool) |
| Control modes | Time and amplitude proportional control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti-reset windup, and on/off |
| Rate | 0 to 399.9 s |
| Reset | 0 to 3999 s |
| Cycle time | 1 to 199 s; set to 0 for on/off |
| Gain | 0.5 to 100% of span; setpoints 1 or 2 |
| Damping | 0000 to 0008 |
| Soak | 00.00 to 99.59 (HH:MM), or OFF |
| Ramp to setpoint | 00.00 to 99.59 (HH:MM), or OFF |
| Auto tune | Operator initiated from front panel |
| Relay output | 250 Vac or 30 Vdc @ 3 A (resistive load); configurable for on/off, PID and ramp and soak |
| Output 1 | SPDT, can be configured as alarm 1 output |
| Output 2 | SPDT, can be configured as alarm 2 output |
| SSR output | 20 to 265 Vac @ 0.05 to 0.5 A (resistive load); continuous |
| DC pulse output | Non-isolated; 10 Vdc @ 20 mA |
| Analog output (output 1 only) | Non-isolated, proportional 0 to 10 Vdc or 0 to 20 mA; 500 Ω max |
| Output 3 retransmission current | 10 V max @ 20 mA output |
| Output 3 retransmission voltage | 20 mA max for 0 to 10 V output |
| Ethernet | Standards compliance IEEE 802.3 10 Base-T |
| Supported protocols | TCP/IP, ARP, HTTPGET |
| RS232/RS422/RS485 | Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status |
| RS485 addressing | Addressable from 0 to 199 |
| Connection | Screw terminals |
| Alarm type | Same as output 1 and 2 |
| Alarm operation | High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations |
| Programmable analog output | Non-isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 Ω max (output 1 only); accuracy is ±1% of FS when following conditions are satisfied: input is not scaled below 1% of input FS, analog output is not scaled below 3% of output FS |
| Power | 90 to 240 Vac ±10%, 50 to 400 Hz, 110 to 375 Vdc, equivalent voltage |
| Low voltage power option | 24 Vac, 12 to 36 Vdc for DPi/CNi/DPiS/CNiS; 20 to 36 Vdc for dual display, ethernet and isolated analog output from qualified safety approved source |
| Isolation power to input/output | 2300 Vac per 1 minute test |
| Isolation for low voltage power option | 1500 Vac per 1 minute test |
| Isolation power to relay/SSR output | 2300 Vac per 1 minute test |
| Isolation relay/SSR to relay/SSR output | 2300 Vac per 1 minute test |
| Isolation RS232/485 to input/output | 500 Vac per 1 minute test |
| Environmental conditions all models | 32 to 131°F (0 to 55°C) 90% RH non-condensing |
| Approvals | UL, C-UL, UKCA, CE per EN61010-1:2001, FM (temperature units only) |
| Protection | NEMA 4X/Type 4 (IP65) front bezel |
| Dimensions | 1.89 x 1.89 x 5" (48 H x 48 W x 127 mm D) Panel cutout: 1.772" (45 mm) square, 1/16 DIN |
| Weight | 0.35 lb (159 g) |