Omega CN8500 Series Temperature/Process Controller, thermocouple input, heat

Model: CN8501TC-R1

Omega CN8500 Series Temperature/Process Controller, thermocouple input, heat

Model: CN8501TC-R1

Designed for temperature control with ramp to setpoint and furnace and oven control, this temperature/process controller provides T/C, Heat. It has accuracy of ±0.2% of full scale, ± digit.

Designed for temperature control with ramp to setpoint and furnace and oven control, this temperature/process controller provides T/C, Heat. It has accuracy of ±0.2% of full scale, ± digit.

Your Price $620.60 USD
Availability 2 to 3 Weeks
Quantity

OMEGA CN8501TC-R1 Offers

The CN8500 temperature controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup.

A dual digital display offers optimum process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters.

Features

  • NEMA 4x (IP65) front panel
  • User selectable ramp to setpoint
  • Bumpless auto/manual operation
  • Optional rs232 or rs485 communications
  • Autotuning heat or cool
  • Thermocouple, RTD, voltage, or current input
  • Dual output and dual alarm capability
  • Optional remote setpoint, transducer power supply and recorder output
  • Optional power, 24 v DC/v AC

Applications

  • Industrial process control
  • Temperature control with ramp to setpoint
  • Heating and cooling regulation
  • Furnace and oven control
  • Networked process monitoring via rs232/rs485

OMEGA CN8501TC-R1 Specifications

Series CN8500 Series
Type temperature/process controller
Configuration T/C
Configuration Heat
Accuracy ±0.2% of full scale, ± digit
Setpoint Resolution 1 count/0.1 count
Repeatability ±1.0 count
Temperature Stability 5 μV/°C maximum; 3 μV/°C typical
Thermocouple Cold Junction Tracking 0.05°C/°C ambient
Common Mode Rejection >100 dB
Series Mode Rejection >70 dB
Process Sampling 10 Hz (100 ms)
Thermocouple Lead Resistance 100 Ω maximum for rated accuracy
Mechanical Relay Output Rated 5 A @ 120 V AC, 3 A @ 240 V AC
Current Output 4 to 20 mA, 500 Ω maximum
Voltage Output 20 V DC pulse, 1 kΩ minimum load
Triac Output SSR, 120/240 V AC, zero voltage switched rated 1 A continuous, 10 A surge @ 77°F (25°C)
Power 115 to 230 V AC ±10%, 50/60 Hz; 115 to 300 V DC ±10% (auto-polarity), optional 24 V DC/V AC
Display Dual LED, 4-digit, orange process display, green menu/parameter display; 0.37" (9.2 mm)
Power Consumption Less than 6 VA (instrument) @ 120 V AC
Operating Ambient Range 32 to 131°F (0 to 55°C); 90% RH maximum, non-condensing
Memory Protection Solid state non-volatile memory
Panel Cutout 1.772" (45 mm) square
Depth Behind Panel 3.937" (100 mm)
Front Panel Rating NEMA 4X (IP65)
Inputs Thermocouple, RTD, voltage, or current input
Output #1 Reverse acting (heating)
Output #2 Direct acting (cooling)
Mechanical Relay Rated 5A @ 120 V AC, 3A @ 240 V AC
Current 4 to 20 mA, 500 Ω maximum
Voltage 20 V DC pulse, 1 kΩ minimum load
Triac SSR, 120/240 V AC, zero voltage switched rated 1A continuous, 10 A surge @ 77°F (25°C)
Alarms Optically isolated triac rated 1A, 120/240 V AC @ 77°F (25°C)
Setpoint Limits Limited to configured range for thermocouple and RTD; limited to scaled range
Alarms (Control) Adjustable for high/low, process or deviation
Rate 0 to 900 seconds
Reset 0 to 3600 seconds
Cycle Time 0.2 to 120 seconds
Gain 0 to 400
Gain Ratio 0 to 2.0 (in 0.1 increments)
On/Off Deadband 1 to 100 counts
Spread (Output 2) 0 to 100 counts (above setpoint)
Damping Adjustable (low, normal or high)
Response Time 0.1, 1.0, or 10 s
Ramp to Setpoint 1 to 100 minutes
Decimal Position Selectable
Autotune Operator initiated from front panel
Manual Control Operator initiated from front panel
Control Algorithms P, PI, PD, PID, or on/off
Connections Rear barrier strip with locking terminals
Communication (Optional) RS232 or RS485 communications
Input Range, Iron-Constantan 0 to 1400°F (-18 to 760°C), resolution 34°F (1°C)
Input Range, CHROMEGA®-ALOMEGA® 0 to 2460°F (-18 to 1349°C), resolution 34°F (1°C)
Input Range, Copper-Constantan -200 to 600°F (-129 to 316°C), resolution 34°F (1°C)
Input Range, OMEGALLOY® 0 to 2370°F (-18 to 1299°C), resolution 34°F (1°C)
Input Range, Pt/13%Rh-Pt 0 to 3200°F (-18 to 1760°C), resolution 34°F (1°C)
Input Range, Pt/10%Rh-Pt 0 to 3200°F (-18 to 1760°C), resolution 34°F (1°C)
Input Range, 3-wire 100 Ω Pt -328 to 1562°F (-200 to 850°C), resolution 34°F (1°C)
Input Range, 3-wire 100 Ω Pt (RTD) -199.0 to 450.0°F (-128.8 to 232.2°C), resolution 0.1°F (0.1°C)
Input Range, V5 0 to 5 V, 1 to 5 V Scalable (-1999 to 9999) Selectable
Input Range, V10 0 to 10 V, 2 to 10 V Scalable (-1999 to 9999) Selectable
Dimensions 2.1 x 2.1 x 0.72" (53 x 53 x 18.3 mm) bezel
Weight 8 oz (0.25 kg)

What's included with the OMEGA CN8501TC-R1

  • Omega CN8500 Series Temperature/Process Controller, thermocouple input, heat

OMEGA CN8501TC-R1 Offers

The CN8500 temperature controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup.

A dual digital display offers optimum process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters.

Features

  • NEMA 4x (IP65) front panel
  • User selectable ramp to setpoint
  • Bumpless auto/manual operation
  • Optional rs232 or rs485 communications
  • Autotuning heat or cool
  • Thermocouple, RTD, voltage, or current input
  • Dual output and dual alarm capability
  • Optional remote setpoint, transducer power supply and recorder output
  • Optional power, 24 v DC/v AC

Applications

  • Industrial process control
  • Temperature control with ramp to setpoint
  • Heating and cooling regulation
  • Furnace and oven control
  • Networked process monitoring via rs232/rs485

OMEGA CN8501TC-R1 Specifications

Series CN8500 Series
Type temperature/process controller
Configuration T/C
Configuration Heat
Accuracy ±0.2% of full scale, ± digit
Setpoint Resolution 1 count/0.1 count
Repeatability ±1.0 count
Temperature Stability 5 μV/°C maximum; 3 μV/°C typical
Thermocouple Cold Junction Tracking 0.05°C/°C ambient
Common Mode Rejection >100 dB
Series Mode Rejection >70 dB
Process Sampling 10 Hz (100 ms)
Thermocouple Lead Resistance 100 Ω maximum for rated accuracy
Mechanical Relay Output Rated 5 A @ 120 V AC, 3 A @ 240 V AC
Current Output 4 to 20 mA, 500 Ω maximum
Voltage Output 20 V DC pulse, 1 kΩ minimum load
Triac Output SSR, 120/240 V AC, zero voltage switched rated 1 A continuous, 10 A surge @ 77°F (25°C)
Power 115 to 230 V AC ±10%, 50/60 Hz; 115 to 300 V DC ±10% (auto-polarity), optional 24 V DC/V AC
Display Dual LED, 4-digit, orange process display, green menu/parameter display; 0.37" (9.2 mm)
Power Consumption Less than 6 VA (instrument) @ 120 V AC
Operating Ambient Range 32 to 131°F (0 to 55°C); 90% RH maximum, non-condensing
Memory Protection Solid state non-volatile memory
Panel Cutout 1.772" (45 mm) square
Depth Behind Panel 3.937" (100 mm)
Front Panel Rating NEMA 4X (IP65)
Inputs Thermocouple, RTD, voltage, or current input
Output #1 Reverse acting (heating)
Output #2 Direct acting (cooling)
Mechanical Relay Rated 5A @ 120 V AC, 3A @ 240 V AC
Current 4 to 20 mA, 500 Ω maximum
Voltage 20 V DC pulse, 1 kΩ minimum load
Triac SSR, 120/240 V AC, zero voltage switched rated 1A continuous, 10 A surge @ 77°F (25°C)
Alarms Optically isolated triac rated 1A, 120/240 V AC @ 77°F (25°C)
Setpoint Limits Limited to configured range for thermocouple and RTD; limited to scaled range
Alarms (Control) Adjustable for high/low, process or deviation
Rate 0 to 900 seconds
Reset 0 to 3600 seconds
Cycle Time 0.2 to 120 seconds
Gain 0 to 400
Gain Ratio 0 to 2.0 (in 0.1 increments)
On/Off Deadband 1 to 100 counts
Spread (Output 2) 0 to 100 counts (above setpoint)
Damping Adjustable (low, normal or high)
Response Time 0.1, 1.0, or 10 s
Ramp to Setpoint 1 to 100 minutes
Decimal Position Selectable
Autotune Operator initiated from front panel
Manual Control Operator initiated from front panel
Control Algorithms P, PI, PD, PID, or on/off
Connections Rear barrier strip with locking terminals
Communication (Optional) RS232 or RS485 communications
Input Range, Iron-Constantan 0 to 1400°F (-18 to 760°C), resolution 34°F (1°C)
Input Range, CHROMEGA®-ALOMEGA® 0 to 2460°F (-18 to 1349°C), resolution 34°F (1°C)
Input Range, Copper-Constantan -200 to 600°F (-129 to 316°C), resolution 34°F (1°C)
Input Range, OMEGALLOY® 0 to 2370°F (-18 to 1299°C), resolution 34°F (1°C)
Input Range, Pt/13%Rh-Pt 0 to 3200°F (-18 to 1760°C), resolution 34°F (1°C)
Input Range, Pt/10%Rh-Pt 0 to 3200°F (-18 to 1760°C), resolution 34°F (1°C)
Input Range, 3-wire 100 Ω Pt -328 to 1562°F (-200 to 850°C), resolution 34°F (1°C)
Input Range, 3-wire 100 Ω Pt (RTD) -199.0 to 450.0°F (-128.8 to 232.2°C), resolution 0.1°F (0.1°C)
Input Range, V5 0 to 5 V, 1 to 5 V Scalable (-1999 to 9999) Selectable
Input Range, V10 0 to 10 V, 2 to 10 V Scalable (-1999 to 9999) Selectable
Dimensions 2.1 x 2.1 x 0.72" (53 x 53 x 18.3 mm) bezel
Weight 8 oz (0.25 kg)

What's included with the OMEGA CN8501TC-R1

  • Omega CN8500 Series Temperature/Process Controller, thermocouple input, heat

More OMEGA Products