Omega CN8200 Series Universal Temperature/Process Controller, DC pulse output, single output

Model: CN8201-DC1

Omega CN8200 Series Universal Temperature/Process Controller, DC pulse output, single output-

Image is for reference only, refer to product info for complete details.

Omega CN8200 Series Universal Temperature/Process Controller, DC pulse output, single output

Model: CN8201-DC1

Built for industrial process control, this universal temperature and process controller is supplied with DC Pulse, 1 O/P, 3.5 Digit Dual Display. It has accuracy of ±0.2% FS, ±1 digit. It also suits heating and cooling regulation.

Built for industrial process control, this universal temperature and process controller is supplied with DC Pulse, 1 O/P, 3.5 Digit Dual Display. It has accuracy of ±0.2% FS, ±1 digit. It also suits heating and cooling regulation.

Your Price $564.10 USD
Availability 2 to 3 Weeks
Quantity

OMEGA CN8201-DC1 Offers

The CN8200 temperature/process controller is extremely versatile and user-friendly. During setup, the user needs to review only those parameters relevant to the particular application.

A dual digital display offers optimal process information at a glance. Eight-level ramp/soak control is standard and includes a decimal display on thermocouple ranges, digital display and signal filtering, and a percentage of power limit setting.

Features

  • Field-configurable universal inputs
  • Autotuning, direct- or reverse-acting for both outputs
  • User-selectable ramp to setpoint
  • 8 ramp and 8 soak segments
  • Decimal display in 0.1° for measured temperatures
  • NEMA 4x (IP65) front panel
  • Optional rs232/485 digital communications, contact/digital remote input, transducer excitation, and pv or sv retransmission
  • Optional 24 v AC/v DC power supply

Applications

  • Industrial process control
  • Temperature control with ramp/soak profiles
  • Heating and cooling regulation
  • Furnace and oven control
  • Networked process monitoring via rs232/rs485

OMEGA CN8201-DC1 Specifications

Series CN8200 Series
Type universal temperature and process controller
Configuration DC Pulse
Output type 1 O/P
Display 3.5 Digit Dual Display
Configuration Multiple Ramp & Soak
Accuracy ±0.2% FS, ±1 digit
Setpoint Resolution 1 count/0.1 count
Repeatability ±1 count
Temperature Stability 5 μV/°C maximum
T/C Cold-Junction Tracking 0.05°C/°C ambient
Common Mode Rejection 100 dB
Series Mode Rejection >70 dB
Process Sampling 10 Hz (100 ms)
Thermocouple Lead Resistance 100 Ω maximum for rated accuracy
Mechanical Relay Output Rated 5 A @ 120 V AC, 3 A @ 240 V AC, normally open (NO), normally closed (NC)
Current Output 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2)
Voltage Output 20 V DC pulse
Solid State Relay Output SSR, 120/240 V AC, zero voltage switched, rated 1 A continuous, 10 A surge @ 77°F (25°C)
Power 100 to 250 V, 50/60 Hz (single-phase); 120 to 250 V DC; 24 V AC/24 V DC (optional)
Display Dual LED—4-digit, orange process display; green menu/parameter display; 0.36" (9.2 mm)
Power Consumption Less than 6 VA (instrument) @ 120 V AC
Operating Ambient Range 32 to 131°F (0 to 55°C) @ 90% RH maximum, non-condensing
Panel Cutout 1.771" (45 mm) square
Depth Behind Panel 3.937" (100 mm)
Front-Panel Rating NEMA 4X (IP65)
Input Type See input table (field-configurable universal inputs)
Digital Input For remote setpoint, remote standby or ramp/soak run and hold
Decimal Position Selectable
Output #1 Reverse- or direct-acting, configured from menu
Output #2 Reverse- or direct-acting, configured from menu
Mechanical Relay Rated 5 A @120 V AC, 3 A @ 240 V AC, normally open (NO), normally closed (NC) (output 1); rated 5 A @120 V AC, 3 A @ 240 V AC, NO (output 2)
Current 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2)
Voltage 20 V DC pulse
Solid State Relay SSR, 120/240 V AC, zero voltage switched, rated 1 A continuous, 10 A surge @ 77°F (25°C)
Alarms Mechanical relay rated 5 A @ 120 V AC, 3 A @ 240 V AC, NO; optically isolated SSR rated 1 A, 120/240 V AC @ 77°F (25°C) (77°C); DC alarms, 24 V DC
Transducer Power Supply 5, 10, 12, 15 V DC ±10%
Setpoint Limits Limited to configured range for thermocouple and RTD; limited to scaled range
Alarms (Control) Adjustable for high/low; selectable process or deviation
Rate (Derivative) 0 to 2400 seconds
Reset (Integral) 0 to 9600 seconds
Cycle Time 0.2 to 120 seconds
Proportional Band 1 to span of sensor
Deadband Negative span to positive span of sensor
Hysteresis 1 to span of sensor
Autotune Damping Adjustable (low, normal, or high)
Ramp to Setpoint 1 to 9999 minutes
Autotune Operator-initiated from front panel
Manual Control Operator-initiated from front panel
Events/Alarms 1 to 8
Ramp Setpoint 1 to 9999 minutes
Control Algorithms P, PI, PD, PID, or on/off
Ramp/Soak Programming Intervals 8
Loops 0 to 99
Ramp Time 0 to 9999 minutes
Soak Time 0 to 9999 minutes
Memory Protection Solid state non-volatile memory
Connections Screw terminals
Contacts Twin bifurcated
Communication (Optional) RS232/485 digital communications
Input Range, Iron-Constantan -328 to 1400°F (-200 to 760°C)
Input Range, CHROMEGA®-ALOMEGA® -454 to 2469°F (-270 to 1354°C)
Input Range, Copper-Constantan -454 to 752°F (-270 to 400°C)
Input Range, OMEGALLOY® -450 to 2372°F (-268 to 1300°C)
Input Range, Pt/13%Rh-Pt -58 to 3214°F (-50 to 1768°C)
Input Range, Pt/10%Rh-Pt -58 to 3214°F (-50 to 1768°C)
Input Range, Pt/30%Rh-Pt/6%Rh 32 to 3308°F (0 to 1820°C)
Input Range, W/5%Re-W/26%Re 32 to 4199°F (0 to 2315°C)
Input Range, CHROMEGA®-Constantan -238 to 1832°F (-150 to 1000°C)
Input Range, NNM 18% molybdenum vs nickel -06% cobalt 32 to 2570°F (0 to 1410°C)
Input Range, Platinel II -148 to 2250°F (-100 to 1232°C)
Input Range, (3-wire) 100 Ω Pt -328 to 1562°F (-200 to 850°C)
Input Range, 0 to 1 V Scalable (-1999 to 9999) selectable
Input Range, 1 to 5 V Scalable (-1999 to 9999) selectable
Input Range, 0 to 5 V Scalable (-1999 to 9999) selectable
Input Range, 0 to 10 V Scalable (-1999 to 9999) selectable
Input Range, 10 to 50 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 50 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 10 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 100 mV Scalable (-1999 to 9999) selectable
Input Range, 4 to 20 mA Scalable (-1999 to 9999) selectable
Input Range, 0 to 20 mA Scalable (-1999 to 9999) selectable
Dimensions 2.1 x 2.1 x 0.72" (53.3 x 53.3 x 8.21 mm) bezel
Weight 8 oz (226 g)

What's included with the OMEGA CN8201-DC1

  • Omega CN8200 Series Universal Temperature/Process Controller, DC pulse output, single output

OMEGA CN8201-DC1 Offers

The CN8200 temperature/process controller is extremely versatile and user-friendly. During setup, the user needs to review only those parameters relevant to the particular application.

A dual digital display offers optimal process information at a glance. Eight-level ramp/soak control is standard and includes a decimal display on thermocouple ranges, digital display and signal filtering, and a percentage of power limit setting.

Features

  • Field-configurable universal inputs
  • Autotuning, direct- or reverse-acting for both outputs
  • User-selectable ramp to setpoint
  • 8 ramp and 8 soak segments
  • Decimal display in 0.1° for measured temperatures
  • NEMA 4x (IP65) front panel
  • Optional rs232/485 digital communications, contact/digital remote input, transducer excitation, and pv or sv retransmission
  • Optional 24 v AC/v DC power supply

Applications

  • Industrial process control
  • Temperature control with ramp/soak profiles
  • Heating and cooling regulation
  • Furnace and oven control
  • Networked process monitoring via rs232/rs485

OMEGA CN8201-DC1 Specifications

Series CN8200 Series
Type universal temperature and process controller
Configuration DC Pulse
Output type 1 O/P
Display 3.5 Digit Dual Display
Configuration Multiple Ramp & Soak
Accuracy ±0.2% FS, ±1 digit
Setpoint Resolution 1 count/0.1 count
Repeatability ±1 count
Temperature Stability 5 μV/°C maximum
T/C Cold-Junction Tracking 0.05°C/°C ambient
Common Mode Rejection 100 dB
Series Mode Rejection >70 dB
Process Sampling 10 Hz (100 ms)
Thermocouple Lead Resistance 100 Ω maximum for rated accuracy
Mechanical Relay Output Rated 5 A @ 120 V AC, 3 A @ 240 V AC, normally open (NO), normally closed (NC)
Current Output 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2)
Voltage Output 20 V DC pulse
Solid State Relay Output SSR, 120/240 V AC, zero voltage switched, rated 1 A continuous, 10 A surge @ 77°F (25°C)
Power 100 to 250 V, 50/60 Hz (single-phase); 120 to 250 V DC; 24 V AC/24 V DC (optional)
Display Dual LED—4-digit, orange process display; green menu/parameter display; 0.36" (9.2 mm)
Power Consumption Less than 6 VA (instrument) @ 120 V AC
Operating Ambient Range 32 to 131°F (0 to 55°C) @ 90% RH maximum, non-condensing
Panel Cutout 1.771" (45 mm) square
Depth Behind Panel 3.937" (100 mm)
Front-Panel Rating NEMA 4X (IP65)
Input Type See input table (field-configurable universal inputs)
Digital Input For remote setpoint, remote standby or ramp/soak run and hold
Decimal Position Selectable
Output #1 Reverse- or direct-acting, configured from menu
Output #2 Reverse- or direct-acting, configured from menu
Mechanical Relay Rated 5 A @120 V AC, 3 A @ 240 V AC, normally open (NO), normally closed (NC) (output 1); rated 5 A @120 V AC, 3 A @ 240 V AC, NO (output 2)
Current 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2)
Voltage 20 V DC pulse
Solid State Relay SSR, 120/240 V AC, zero voltage switched, rated 1 A continuous, 10 A surge @ 77°F (25°C)
Alarms Mechanical relay rated 5 A @ 120 V AC, 3 A @ 240 V AC, NO; optically isolated SSR rated 1 A, 120/240 V AC @ 77°F (25°C) (77°C); DC alarms, 24 V DC
Transducer Power Supply 5, 10, 12, 15 V DC ±10%
Setpoint Limits Limited to configured range for thermocouple and RTD; limited to scaled range
Alarms (Control) Adjustable for high/low; selectable process or deviation
Rate (Derivative) 0 to 2400 seconds
Reset (Integral) 0 to 9600 seconds
Cycle Time 0.2 to 120 seconds
Proportional Band 1 to span of sensor
Deadband Negative span to positive span of sensor
Hysteresis 1 to span of sensor
Autotune Damping Adjustable (low, normal, or high)
Ramp to Setpoint 1 to 9999 minutes
Autotune Operator-initiated from front panel
Manual Control Operator-initiated from front panel
Events/Alarms 1 to 8
Ramp Setpoint 1 to 9999 minutes
Control Algorithms P, PI, PD, PID, or on/off
Ramp/Soak Programming Intervals 8
Loops 0 to 99
Ramp Time 0 to 9999 minutes
Soak Time 0 to 9999 minutes
Memory Protection Solid state non-volatile memory
Connections Screw terminals
Contacts Twin bifurcated
Communication (Optional) RS232/485 digital communications
Input Range, Iron-Constantan -328 to 1400°F (-200 to 760°C)
Input Range, CHROMEGA®-ALOMEGA® -454 to 2469°F (-270 to 1354°C)
Input Range, Copper-Constantan -454 to 752°F (-270 to 400°C)
Input Range, OMEGALLOY® -450 to 2372°F (-268 to 1300°C)
Input Range, Pt/13%Rh-Pt -58 to 3214°F (-50 to 1768°C)
Input Range, Pt/10%Rh-Pt -58 to 3214°F (-50 to 1768°C)
Input Range, Pt/30%Rh-Pt/6%Rh 32 to 3308°F (0 to 1820°C)
Input Range, W/5%Re-W/26%Re 32 to 4199°F (0 to 2315°C)
Input Range, CHROMEGA®-Constantan -238 to 1832°F (-150 to 1000°C)
Input Range, NNM 18% molybdenum vs nickel -06% cobalt 32 to 2570°F (0 to 1410°C)
Input Range, Platinel II -148 to 2250°F (-100 to 1232°C)
Input Range, (3-wire) 100 Ω Pt -328 to 1562°F (-200 to 850°C)
Input Range, 0 to 1 V Scalable (-1999 to 9999) selectable
Input Range, 1 to 5 V Scalable (-1999 to 9999) selectable
Input Range, 0 to 5 V Scalable (-1999 to 9999) selectable
Input Range, 0 to 10 V Scalable (-1999 to 9999) selectable
Input Range, 10 to 50 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 50 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 10 mV Scalable (-1999 to 9999) selectable
Input Range, 0 to 100 mV Scalable (-1999 to 9999) selectable
Input Range, 4 to 20 mA Scalable (-1999 to 9999) selectable
Input Range, 0 to 20 mA Scalable (-1999 to 9999) selectable
Dimensions 2.1 x 2.1 x 0.72" (53.3 x 53.3 x 8.21 mm) bezel
Weight 8 oz (226 g)

What's included with the OMEGA CN8201-DC1

  • Omega CN8200 Series Universal Temperature/Process Controller, DC pulse output, single output