Image is for reference only, refer to product info for complete details.
This temperature controller is configured for DC Pulse, 2 O/P, 3.5 Digit Dual Display. It has display of 4-digit, 9-segment LED. It suits factory automation and process control and semiconductor and pharmaceutical processing.
This temperature controller is configured for DC Pulse, 2 O/P, 3.5 Digit Dual Display. It has display of 4-digit, 9-segment LED. It suits factory automation and process control and semiconductor and pharmaceutical processing.
The PLATINUM Series family of microprocessor-based PID controllers offer unparalleled flexibility in process measurement. The automatic hardware configuration recognition eliminates the need for jumpers and allows the firmware to automatically simplify itself, eliminating all menu options that do not apply to a specific configuration. Each unit allows the user to select the input type from 9 thermocouple types (J, K, T, E, R, S, B, C, and N), Pt RTDs (100, 500, or 1000 Ω, with either 385, 392, or 3916 curve), thermistors (2250 Ω, 5K Ω, and 10K Ω), DC voltage, or DC current, and strain and bridge inputs.
Features
Applications
| Input voltage | 80 ~ 260 Vac 50/60Hz; 24 Vac 50/60Hz ±10%; 24 Vdc ±10% |
| Series | CN08D Series |
| Power consumption | 8 VA max. |
| Type | temperature controller |
| Display method | LCD display. Process value (PV): Yellow color, Set point (SV): Green color |
| Configuration | DC Pulse |
| Sensor type | Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK 3-wire Platinum RTD: Pt100, JPt100 Resistance: Cu50, Ni120 Analog input: 0 ~ 5 Vdc, 0 ~ 10 Vdc, 0 ~ 20 mA, 4 ~ 20 mA, 0 ~ 50 mVdc |
| Output type | 2 O/P |
| Control mode | PID, PID program control (Ramp/Soak control), FUZZY, Self-tuning, Manual and On/Off |
| Display | 3.5 Digit Dual Display |
| Control output | Relay output: Max. load 250 Vac, 5 A resistive load Voltage pulse output: 12 Vdc, Max. output current 40 mA Current output: DC 4 ~ 20 mA output (Load resistance: Max. 500 ohm) Analog voltage output: 0 ~ 10 Vdc |
| Configuration | Serial |
| Alarm output type | Relay output: Max. load 250 Vac, 3 A resistive load |
| Display | 4-digit, 9-segment LED |
| Display accuracy | 0 or 1 digit to the right of the decimal point (selectable) |
| Display Color | Bright 3-color (RED, GREEN, and AMBER) |
| Sampling rate | Analog input: 0.1 sec/per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan |
| Input Types | Thermocouple, RTD, thermistor, analog voltage, analog current, strain |
| Vibration resistance | 10 to 55Hz, 10 m/s2 for 10 min, each in X, Y and Z directions |
| Thermocouple Input (ITS 90) | K, J, T, E, R, S, B, C, N |
| Shock resistance | Max. 300 m/s2, 3 times in each 3 axes, 6 directions |
| RTD Input (ITS 90) | 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves |
| Ambient temperature | 0°C ~ +50°C |
| Thermistor Input | 2252 Ω, 5K Ω, 10K Ω |
| Storage temperature | -20°C ~ +65°C |
| Strain Input | ±50 mV, ±100 mV |
| Altitude | Max. 2000 m |
| Current Input | 4 to 20 mA, 0 to 24 mA scalable |
| Relative humidity | 35% ~ 80% RH (non-condensing) |
| Voltage Input | -100 to 100 mV, -1 to 1 V, -10 to 10 V DC scalable |
| RS-485 transmission speed | 2,400, 4,800, 9,600, 19,200, 38,400 bps |
| Resolution | 0.1° temperature; 10 μV process |
| Communication protocol | Modbus (ASCII or RTU) |
| A/D Conversion | 24-bit sigma delta |
| Reading Rate | 20 samples per second |
| Accuracy (Process Voltage) | 0.03% FS |
| Accuracy (Process Current) | 0.03% FS |
| Control Action | Reverse (heat), direct (cool), or heat/cool |
| Auto-Tune | Operator initiated from front panel |
| Adaptive Tune | User selectable; fuzzy logic continuous PID tuning optimization |
| Ramp and Soak | Up to 99 saved ramp and soak programs, up to 8 ramp and 8 soak segments with individually selectable events per program, chainable |
| Communications | USB standard, optional serial and Ethernet |
| Serial | Software selectable RS232 or RS485; programmable 1200 to 115.2 K baud |
| Protocols | OMEGA ASCII, MODBUS® ASCII/RTU |
| Approvals | UL, cUL, CE |
| Protection | NEMA 1 front bezel |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm) |
| Environmental Conditions | 32 to 122°F (0 to 50°C), 90% RH non-condensing |
| Line Voltage/Power | 90 to 240 V AC ±10%, 50 to 400 Hz, 110 to 375 V DC equivalent voltage |
| Polarity | Bipolar |
| Input Impedances | Process/Strain: 10M Ω for ±100 mV, 1M Ω for other voltage ranges; Process Current: 5 Ω; Thermocouple: 10K Ω maximum |
| Auxiliary Input (Remote Setpoint) | 3.5K Ω for 0 to 10 V, 50K Ω for 0 to 1 V, 50 Ω for current |
| Excitation | Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 V DC @ 25 mA |
| Temperature Stability | RTD: 0.04°C/°C maximum; Thermocouple @ 77°F (25°C): 0.05°C/°C (cold junction compensation); Process/Strain: 50 ppm/°C |
| Digital Filter | Programmable from 0.05 seconds (filter = 1) to 6.4 seconds (filter = 128) |
| CMRR | 120 dB |
| Setpoint Adjustment | 4 digit (-9999 to +9999 counts), 6 digit (-99999 to +999999 counts) |
| Warm-Up to Rated Accuracy | 30 mins |
| Control Modes | ON/OFF or the following time/amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative |
| Cycle Time | 0.1 to 199 seconds |
| Ramp and Soak Segment Times | 00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS) |
| Analog | Non-isolated, programmable for control or retransmission; voltage output 0 to 10 V; 500 Ω minimum; accuracy 0.1%; current output 0 to 20 mA; 500 Ω maximum; accuracy 0.1%; step response time 100 ms |
| DC Pulse | Non-isolated; 10 V DC at 20 mA |
| SPST Relay | Single pole, single throw mechanical relay, 250 V AC or 30 V DC at 3 A (resistive load) |
| SPDT Relay | Single pole, double throw mechanical relay, 250 V AC or 30 V DC at 3 A (resistive load) |
| SSR | 20 to 265 V AC at 0.05 to 0.5 A (resistive load); continuous |
| Isolated DC Pulse | 1.5 kV isolation; 10 V DC at 20 mA |
| Isolated Analog | 1.5 kV isolation, programmable for control or retransmission; voltage output 0 to 10 V; 500 Ω minimum; accuracy 0.1%; current output 0 to 20 mA; 500 Ω maximum; accuracy 0.1%; step response time 100 ms |
| USB | Female micro-USB; USB 2.0 host or device |
| Ethernet | Standard RJ45; IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET |
| Isolation, Power to Input/Output | 2300 V AC per 1 minimum test; 1500 V AC per 1 minimum test (low voltage/power option) |
| Isolation, Power to Relays/SSR Outputs | 2300 V AC per 1 minimum test |
| Isolation, Relays/SSR to Relay/SSR Outputs | 2300 V AC per 1 minimum test |
| Isolation, RS232/RS485 to Inputs/Outputs | 500 V AC per 1 minimum test |
| External Fuse Required | Time-Delay, UL 248-14 Listed: 100 mA/250 V; 400 mA/250 V (low voltage option); Time-Lag, IEC 127-3 Recognized: 100 mA/250 V; 400 mA/250 V (low voltage option) |
| Low Voltage/Power Option | External power source must meet Safety Agency Approvals; units can be powered safely with 24 V AC, but no CE/UL certification claimed; CN8Pt, CN16Pt, CN32Pt Models: 12 to 36 V DC, 3 W power; CN8DPt, CN8EPt, CN16DPt Models: 20 to 36 V DC, 4 W power |
| Display Digit Height | 0.83" (21 mm) and 0.40" (10.2 mm) (CN8DPt dual display) |
| Power (Wattage) | 5 W power (CN8DPt dual-display model) |
| Dimensions | 1.89 x 3.78 x 5" (48 x 96 x 127 mm) |
| Weight | 0.65 lb (295 g) (CN8Pt) |
| Input voltage | 80 ~ 260 Vac 50/60Hz; 24 Vac 50/60Hz ±10%; 24 Vdc ±10% |
| Series | CN08D Series |
| Power consumption | 8 VA max. |
| Type | temperature controller |
| Display method | LCD display. Process value (PV): Yellow color, Set point (SV): Green color |
| Configuration | DC Pulse |
| Sensor type | Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK 3-wire Platinum RTD: Pt100, JPt100 Resistance: Cu50, Ni120 Analog input: 0 ~ 5 Vdc, 0 ~ 10 Vdc, 0 ~ 20 mA, 4 ~ 20 mA, 0 ~ 50 mVdc |
| Output type | 2 O/P |
| Control mode | PID, PID program control (Ramp/Soak control), FUZZY, Self-tuning, Manual and On/Off |
| Display | 3.5 Digit Dual Display |
| Control output | Relay output: Max. load 250 Vac, 5 A resistive load Voltage pulse output: 12 Vdc, Max. output current 40 mA Current output: DC 4 ~ 20 mA output (Load resistance: Max. 500 ohm) Analog voltage output: 0 ~ 10 Vdc |
| Configuration | Serial |
| Alarm output type | Relay output: Max. load 250 Vac, 3 A resistive load |
| Display | 4-digit, 9-segment LED |
| Display accuracy | 0 or 1 digit to the right of the decimal point (selectable) |
| Display Color | Bright 3-color (RED, GREEN, and AMBER) |
| Sampling rate | Analog input: 0.1 sec/per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan |
| Input Types | Thermocouple, RTD, thermistor, analog voltage, analog current, strain |
| Vibration resistance | 10 to 55Hz, 10 m/s2 for 10 min, each in X, Y and Z directions |
| Thermocouple Input (ITS 90) | K, J, T, E, R, S, B, C, N |
| Shock resistance | Max. 300 m/s2, 3 times in each 3 axes, 6 directions |
| RTD Input (ITS 90) | 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves |
| Ambient temperature | 0°C ~ +50°C |
| Thermistor Input | 2252 Ω, 5K Ω, 10K Ω |
| Storage temperature | -20°C ~ +65°C |
| Strain Input | ±50 mV, ±100 mV |
| Altitude | Max. 2000 m |
| Current Input | 4 to 20 mA, 0 to 24 mA scalable |
| Relative humidity | 35% ~ 80% RH (non-condensing) |
| Voltage Input | -100 to 100 mV, -1 to 1 V, -10 to 10 V DC scalable |
| RS-485 transmission speed | 2,400, 4,800, 9,600, 19,200, 38,400 bps |
| Resolution | 0.1° temperature; 10 μV process |
| Communication protocol | Modbus (ASCII or RTU) |
| A/D Conversion | 24-bit sigma delta |
| Reading Rate | 20 samples per second |
| Accuracy (Process Voltage) | 0.03% FS |
| Accuracy (Process Current) | 0.03% FS |
| Control Action | Reverse (heat), direct (cool), or heat/cool |
| Auto-Tune | Operator initiated from front panel |
| Adaptive Tune | User selectable; fuzzy logic continuous PID tuning optimization |
| Ramp and Soak | Up to 99 saved ramp and soak programs, up to 8 ramp and 8 soak segments with individually selectable events per program, chainable |
| Communications | USB standard, optional serial and Ethernet |
| Serial | Software selectable RS232 or RS485; programmable 1200 to 115.2 K baud |
| Protocols | OMEGA ASCII, MODBUS® ASCII/RTU |
| Approvals | UL, cUL, CE |
| Protection | NEMA 1 front bezel |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm) |
| Environmental Conditions | 32 to 122°F (0 to 50°C), 90% RH non-condensing |
| Line Voltage/Power | 90 to 240 V AC ±10%, 50 to 400 Hz, 110 to 375 V DC equivalent voltage |
| Polarity | Bipolar |
| Input Impedances | Process/Strain: 10M Ω for ±100 mV, 1M Ω for other voltage ranges; Process Current: 5 Ω; Thermocouple: 10K Ω maximum |
| Auxiliary Input (Remote Setpoint) | 3.5K Ω for 0 to 10 V, 50K Ω for 0 to 1 V, 50 Ω for current |
| Excitation | Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 V DC @ 25 mA |
| Temperature Stability | RTD: 0.04°C/°C maximum; Thermocouple @ 77°F (25°C): 0.05°C/°C (cold junction compensation); Process/Strain: 50 ppm/°C |
| Digital Filter | Programmable from 0.05 seconds (filter = 1) to 6.4 seconds (filter = 128) |
| CMRR | 120 dB |
| Setpoint Adjustment | 4 digit (-9999 to +9999 counts), 6 digit (-99999 to +999999 counts) |
| Warm-Up to Rated Accuracy | 30 mins |
| Control Modes | ON/OFF or the following time/amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative |
| Cycle Time | 0.1 to 199 seconds |
| Ramp and Soak Segment Times | 00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS) |
| Analog | Non-isolated, programmable for control or retransmission; voltage output 0 to 10 V; 500 Ω minimum; accuracy 0.1%; current output 0 to 20 mA; 500 Ω maximum; accuracy 0.1%; step response time 100 ms |
| DC Pulse | Non-isolated; 10 V DC at 20 mA |
| SPST Relay | Single pole, single throw mechanical relay, 250 V AC or 30 V DC at 3 A (resistive load) |
| SPDT Relay | Single pole, double throw mechanical relay, 250 V AC or 30 V DC at 3 A (resistive load) |
| SSR | 20 to 265 V AC at 0.05 to 0.5 A (resistive load); continuous |
| Isolated DC Pulse | 1.5 kV isolation; 10 V DC at 20 mA |
| Isolated Analog | 1.5 kV isolation, programmable for control or retransmission; voltage output 0 to 10 V; 500 Ω minimum; accuracy 0.1%; current output 0 to 20 mA; 500 Ω maximum; accuracy 0.1%; step response time 100 ms |
| USB | Female micro-USB; USB 2.0 host or device |
| Ethernet | Standard RJ45; IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET |
| Isolation, Power to Input/Output | 2300 V AC per 1 minimum test; 1500 V AC per 1 minimum test (low voltage/power option) |
| Isolation, Power to Relays/SSR Outputs | 2300 V AC per 1 minimum test |
| Isolation, Relays/SSR to Relay/SSR Outputs | 2300 V AC per 1 minimum test |
| Isolation, RS232/RS485 to Inputs/Outputs | 500 V AC per 1 minimum test |
| External Fuse Required | Time-Delay, UL 248-14 Listed: 100 mA/250 V; 400 mA/250 V (low voltage option); Time-Lag, IEC 127-3 Recognized: 100 mA/250 V; 400 mA/250 V (low voltage option) |
| Low Voltage/Power Option | External power source must meet Safety Agency Approvals; units can be powered safely with 24 V AC, but no CE/UL certification claimed; CN8Pt, CN16Pt, CN32Pt Models: 12 to 36 V DC, 3 W power; CN8DPt, CN8EPt, CN16DPt Models: 20 to 36 V DC, 4 W power |
| Display Digit Height | 0.83" (21 mm) and 0.40" (10.2 mm) (CN8DPt dual display) |
| Power (Wattage) | 5 W power (CN8DPt dual-display model) |
| Dimensions | 1.89 x 3.78 x 5" (48 x 96 x 127 mm) |
| Weight | 0.65 lb (295 g) (CN8Pt) |