Image is for reference only, refer to product info for complete details.
A perforated bus bar rated for 23 amps. It provides a convenient common connection point for wiring multiple circuits in high-temperature terminal block or panel assemblies.
A perforated bus bar rated for 23 amps. It provides a convenient common connection point for wiring multiple circuits in high-temperature terminal block or panel assemblies.
High-temperature wire and bus bars are recommended for connections to heater terminals and for runs in heated zones. When ambient temperature exceeds the maximum rating of standard wire, these manganese-nickel bus bars provide a high-temperature connection.
Features
Applications
| Series | BB Series |
| Type | Heater Hook-Up Wire Accessory |
| Maximum temperature | 1112°F (600°C) |
| Maximum wire temperature | 1112°F (600°C) |
| Bus bar material (BBS/BBP) | Manganese-Nickel |
| Bus bar maximum wire temperature (BBS/BBP) | 1112°F (600°C) |
| Bus bar perforated (BBP): Width | 0.5" (13 mm) |
| Bus bar perforated (BBP): Thickness | 0.62" (15.7 mm) |
| Bus bar perforated (BBP): Amps | 23 |
| Perforated bus bar slots | 11/32 x 7/32" (8.7 x 5.6 mm) slots on 7/16" (11.1 mm) centers |
| Bus bar minimum order | Specify number of feet: 10' (3.05 m) minimum |
| Bus bar amps note | These current values will cause the conductor to operate at 100°F (38°C) above surrounding ambient; values can also be used for bare wire with porcelain tubes or bead insulation. |
| Bus bar capacity note | Bus bars can be used in multiples for higher amperage capacity (approximately 33.5% per bus bar) than listed. |
| Series | BB Series |
| Type | Heater Hook-Up Wire Accessory |
| Maximum temperature | 1112°F (600°C) |
| Maximum wire temperature | 1112°F (600°C) |
| Bus bar material (BBS/BBP) | Manganese-Nickel |
| Bus bar maximum wire temperature (BBS/BBP) | 1112°F (600°C) |
| Bus bar perforated (BBP): Width | 0.5" (13 mm) |
| Bus bar perforated (BBP): Thickness | 0.62" (15.7 mm) |
| Bus bar perforated (BBP): Amps | 23 |
| Perforated bus bar slots | 11/32 x 7/32" (8.7 x 5.6 mm) slots on 7/16" (11.1 mm) centers |
| Bus bar minimum order | Specify number of feet: 10' (3.05 m) minimum |
| Bus bar amps note | These current values will cause the conductor to operate at 100°F (38°C) above surrounding ambient; values can also be used for bare wire with porcelain tubes or bead insulation. |
| Bus bar capacity note | Bus bars can be used in multiples for higher amperage capacity (approximately 33.5% per bus bar) than listed. |