MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Model: 410074US2

MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Model: 410074US2

The analyzer is designed for measuring emissions. It is designed to focus on 7 common gases.

The analyzer is designed for measuring emissions. It is designed to focus on 7 common gases.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

MRU OPTIMAX Portable Biogas Analyzer, O<sub>2</sub>/CH<sub>4</sub>/CO<sub>2</sub>-

MRU OPTIMAX Portable Biogas Analyzer, O2/CH4/CO2

Model: 420074US2

Unleash the full potential of biogas operations with this highly versatile and dependable analyzer that is ideal for fast biogas and emissions analysis at biogas and bio-methane sites. In addition, this handheld analyzer analyzes O2, CH4, CO2, and biogas pressure and makes your biogas process more cost-effective.


MRU 410074US2 Offers



The MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth improves monitoring of emissions and exhausts. The analyzer is calibrated for 7 common gases in emissions to provide greater reliability. It is designed with an intuitive software menu to allow the user to adjust the settings directly from the display.

Features

  • Calibrated to operate on 7 types of gas
  • Designed to monitor emission of combustion and industrial processes
  • Integrated menu and clear display for ease of operation
  • Uses Bluetooth® for faster data transfer and remote control

MRU 410074US2 Specifications

Measuring Components
Methane (MH4) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Carbon Dioxide (CO2) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Hydrogen Sulfide (H2S) Measuring method: Electro-chemical
Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Oxygen (O2) Long Life Measuring method: Electro-chemical
Measuring range: 0 to 25%
Resolution: 0.01%
Repeatability: ±0.2% absolute
Hydrogen (H2) Measuring method: Electro-chemical
Measuring range: 0 to 1000 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Nitrogen (N2) Measuring method: Calculated
Measuring range: 0 to 100%
Resolution: 0.1%
Calorific Value (Hu) Measuring method: Calculated
Measuring range: 0 to 36 MJ/m3
Resolution: 0.01 MJ/m3
Carbon Monoxide (CO) Measuring method: Electro-chemical
Measuring range: 0 to 10,000/20,000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 4000 ppm), 10% (>4000 ppm) reading
Nitric Monoxide (NO) Measuring method: Electro-chemical
Measuring range: 0 to 1000/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Nitric Dioxide (NO2) Measuring method: Electro-chemical
Measuring range: 0 to 200/1000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 200 ppm), 10% (>200 ppm) reading
Nitrogen Oxide (NOx) Measuring method: Calculated
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Sulfur Dioxide (SO2) Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 2000 ppm), 10% (>5000 ppm) reading
Hydrogen Sulfide Dioxide (H2S) Measuring range: 0 to 500 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>5000 ppm) reading
Gas Flow Velocity Measuring method: S-type probe
Measuring range: 1 to 100 m/s
Resolution: 0.1 m/s
Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s)
Flow Rate Measuring method: Calculated
Measuring range: 0.1 to 6000 m3/s
Resolution: 0.1 m3/s
Repeatability: User settable cross section area
Differential Temperature Measuring method: NiCrNi
Measuring range: -40 to 2192°F (-40 to 1200°C)
Resolution: 1°F
Repeatability: ±4°F (2°C), 0.5% reading
Differential Pressure Measuring method: Piezo
Measuring range: ±120 inH2O (300 hPa)
Resolution: 0.01 hPa
Repeatability: ±0.01 inH2O (0.03 hPa), 1% reading
Calculated Values (Fuel Type Depending)
Carbon Dioxide (CO2) Range: 0 to 20%
Accuracy: ±0.3 vol. - % abs.
Heat Losses qA 0 to 99.9%
Efficiency 0 to 120%
Air Ratio 1 to 9.99%
Excess Air 0 to 99.9%
Combustion Calculations Based on the large fuel type list like: CO2, excess air, heat losses, co,bustion efficiency, flue gas dew point, CO/CO2 ratio
Emission Calculations mg/Nm3 NO2 true measurement of NOx = NO + NO2, including O2 referencing (normalisation) to user settle value
General Specifications
Operating Conditions Temperature: 41°F to 113°F (5 to 45°C) max. 95% RH, none condensing
Storage: 4°F to 122°F (-20°C to 50°C)
Data Storage Up to 16,000 measurements
Interfaces SD card reader, USB, infrared, Bluetooth
Power Supply Internal: Lithium-Ion battery, 15 hours operation time
Mains: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A
Protection Class IP30
Cerfication TUV ByRgG 280, VDI 4206-1, EN 50379
Dimensions 2.05 x 4.33 x 8.86" (52 x 110 x 225 mm)
Weight Approximately 1.7 lbs (750 g)
Click here for complete specifications on the MRU 410074US2

What's included with the MRU 410074US2

  • MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Click on a category to view a selection of compatible accessories with the MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth.

MRU 62931 ABS Transport case with large compartment 62931
The case protects equipment during travel. It features a large compartment for better storage.




MRU 63677 IR Printer 63677
The printer improves recording capacity during operation. It is designed to work with manometers and gas analyzers.




MRU 59465 Printer Paper Rolls, 5-pack 59465
The paper provides a convenient space to record data. It offers plenty of room for countless operations.




MRU 65670 Stainless Steel Mounting Fitting, 0.47", male 65670
The fitting improves the stability of probes during operation. It is designed for stationary monitoring.




MRU 410074US2 Offers



The MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth improves monitoring of emissions and exhausts. The analyzer is calibrated for 7 common gases in emissions to provide greater reliability. It is designed with an intuitive software menu to allow the user to adjust the settings directly from the display.

Features

  • Calibrated to operate on 7 types of gas
  • Designed to monitor emission of combustion and industrial processes
  • Integrated menu and clear display for ease of operation
  • Uses Bluetooth® for faster data transfer and remote control

MRU 410074US2 Specifications

Measuring Components
Methane (MH4) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Carbon Dioxide (CO2) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Hydrogen Sulfide (H2S) Measuring method: Electro-chemical
Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Oxygen (O2) Long Life Measuring method: Electro-chemical
Measuring range: 0 to 25%
Resolution: 0.01%
Repeatability: ±0.2% absolute
Hydrogen (H2) Measuring method: Electro-chemical
Measuring range: 0 to 1000 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Nitrogen (N2) Measuring method: Calculated
Measuring range: 0 to 100%
Resolution: 0.1%
Calorific Value (Hu) Measuring method: Calculated
Measuring range: 0 to 36 MJ/m3
Resolution: 0.01 MJ/m3
Carbon Monoxide (CO) Measuring method: Electro-chemical
Measuring range: 0 to 10,000/20,000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 4000 ppm), 10% (>4000 ppm) reading
Nitric Monoxide (NO) Measuring method: Electro-chemical
Measuring range: 0 to 1000/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Nitric Dioxide (NO2) Measuring method: Electro-chemical
Measuring range: 0 to 200/1000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 200 ppm), 10% (>200 ppm) reading
Nitrogen Oxide (NOx) Measuring method: Calculated
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Sulfur Dioxide (SO2) Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 2000 ppm), 10% (>5000 ppm) reading
Hydrogen Sulfide Dioxide (H2S) Measuring range: 0 to 500 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>5000 ppm) reading
Gas Flow Velocity Measuring method: S-type probe
Measuring range: 1 to 100 m/s
Resolution: 0.1 m/s
Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s)
Flow Rate Measuring method: Calculated
Measuring range: 0.1 to 6000 m3/s
Resolution: 0.1 m3/s
Repeatability: User settable cross section area
Differential Temperature Measuring method: NiCrNi
Measuring range: -40 to 2192°F (-40 to 1200°C)
Resolution: 1°F
Repeatability: ±4°F (2°C), 0.5% reading
Differential Pressure Measuring method: Piezo
Measuring range: ±120 inH2O (300 hPa)
Resolution: 0.01 hPa
Repeatability: ±0.01 inH2O (0.03 hPa), 1% reading
Calculated Values (Fuel Type Depending)
Carbon Dioxide (CO2) Range: 0 to 20%
Accuracy: ±0.3 vol. - % abs.
Heat Losses qA 0 to 99.9%
Efficiency 0 to 120%
Air Ratio 1 to 9.99%
Excess Air 0 to 99.9%
Combustion Calculations Based on the large fuel type list like: CO2, excess air, heat losses, co,bustion efficiency, flue gas dew point, CO/CO2 ratio
Emission Calculations mg/Nm3 NO2 true measurement of NOx = NO + NO2, including O2 referencing (normalisation) to user settle value
General Specifications
Operating Conditions Temperature: 41°F to 113°F (5 to 45°C) max. 95% RH, none condensing
Storage: 4°F to 122°F (-20°C to 50°C)
Data Storage Up to 16,000 measurements
Interfaces SD card reader, USB, infrared, Bluetooth
Power Supply Internal: Lithium-Ion battery, 15 hours operation time
Mains: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A
Protection Class IP30
Cerfication TUV ByRgG 280, VDI 4206-1, EN 50379
Dimensions 2.05 x 4.33 x 8.86" (52 x 110 x 225 mm)
Weight Approximately 1.7 lbs (750 g)
Click here for complete specifications on the MRU 410074US2

What's included with the MRU 410074US2

  • MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Click on a category to view a selection of compatible accessories with the MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth.

MRU 62931 ABS Transport case with large compartment 62931
The case protects equipment during travel. It features a large compartment for better storage.




MRU 63677 IR Printer 63677
The printer improves recording capacity during operation. It is designed to work with manometers and gas analyzers.




MRU 59465 Printer Paper Rolls, 5-pack 59465
The paper provides a convenient space to record data. It offers plenty of room for countless operations.




MRU 65670 Stainless Steel Mounting Fitting, 0.47", male 65670
The fitting improves the stability of probes during operation. It is designed for stationary monitoring.




More MRU Products