This electronic micrometer can accept a multitude of cartridge heads for a variety of applications in step and sheet thickness measurements. 6 probes can be connected to the one unit, and by utilizing the RS link you can create a multi-point measuring system and connect up to 10 units together, with a total of 60 probes.
This electronic micrometer can accept a multitude of cartridge heads for a variety of applications in step and sheet thickness measurements. 6 probes can be connected to the one unit, and by utilizing the RS link you can create a multi-point measuring system and connect up to 10 units together, with a total of 60 probes.
This instrument uses a differential inductance displacement sensor energized by a 5kHz AC exciting voltage applied across two identical series-connected coils, L1 and L2. An iron core connected to the stylus moves close to both cores and varies the impedance of each coil depending on its position, and the voltage at the junction between the coils varies as the impedance difference.
Two resistors, R1 and R2, form a bridge circuit with the coils and the bridge output voltage drives electronic amplification and conditioning circuits to provide a voltage signal proportional to displacement of the stylus.
To calibrate the EV-16A properly, be sure to purchase dedicated display unit D-EV. When multiple units of EV-16A units are to be used, at least one D-EV unit is required.
As a power supply is not supplied as standard, an appropriate power supply with a current capacity of 1A or more must be provided for each EV-16A.
Features
Major Functions
Applications
With the appropriate Cartridge Head, the Mu-Checker can be used in a multitude of applications.
Number of Input Probes | 6 axes |
Quantizing Error | ±1 LCD |
Resolution (mm) | Max. counting range 0.001(±2.000mm), 0.0001(±0.200mm) |
LED Display | Parameter display: 8 digits (setting display), error message: 1 digit |
Error Message | Power supply voltage error, probe malfunction, etc. |
External Display | Dedicated external display unit: D-EV (special option) connectable |
Number of Input Switches | 4 |
Input Switch Function | Measurement mode selection, parameter setting |
Applicable Probes | Lever head and cartridge head |
Click on a category to view a selection of compatible accessories with the Mitutoyo EV-16A Mu-Checker Electronic Micrometer Counter.
Number of Input Probes | 6 axes |
Quantizing Error | ±1 LCD |
Resolution (mm) | Max. counting range 0.001(±2.000mm), 0.0001(±0.200mm) |
LED Display | Parameter display: 8 digits (setting display), error message: 1 digit |
Error Message | Power supply voltage error, probe malfunction, etc. |
External Display | Dedicated external display unit: D-EV (special option) connectable |
Number of Input Switches | 4 |
Input Switch Function | Measurement mode selection, parameter setting |
Applicable Probes | Lever head and cartridge head |
Click on a category to view a selection of compatible accessories with the Mitutoyo EV-16A Mu-Checker Electronic Micrometer Counter.