Produces 3-step/5-step, this linear gauge counter features a simple display, multi-step Go/No Go judgment and output, BCD output, and open collector. Additionally, this counter has a differential square-wave applicable input and is compatible with the LGF, LGK, LGB, LGM, LGH, LG, and LGE linear gauges.
Produces 3-step/5-step, this linear gauge counter features a simple display, multi-step Go/No Go judgment and output, BCD output, and open collector. Additionally, this counter has a differential square-wave applicable input and is compatible with the LGF, LGK, LGB, LGM, LGH, LG, and LGE linear gauges.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
| Applicable Gauge Head | LGE, LGF, LGK, LGB, LGM, LG, LGH (Not compatible with LGH110, reference point or sine wave models) |
| Number of Gauge Inputs | 1 |
| Quantizing Error | ±1 count |
| Maximum Input Frequency | 1.25 MHz, response speed depends on gauge specification |
| Resolution | 0.01 mm (±9999.99 mm)/0.0005" (±99.9995")/0.001" (±999.999") 0.005mm (±9999.995mm)/0.00005" (±9.99995")/0.0001" (±99.999") 0.001mm (±999.999mm)/0.00005" (±9.99995")/0.0001"(±99.999") 0.0005mm (±99.9995mm)/0.000005" (±.999995")/0.00001" (±9.99999") 0.0001mm (±99.9999mm)/0.000005" (±.999995")/0.00001" (±9.99999") |
| Display | Sign plus 6 digits (Green LED) |
| Tolerance Judgment | Display: LED display (3 steps: Amber, green, red/5 steps: amber, amber flashing, green, red flashing, red) L1 to L5 (Open-collector/switchover between L1 to L5 and BCD output with parameter) |
| Control | Output: Normal operation signal (NOM): open-collector Input: Pre setting, display hold, peak value clear, tolerance judgment BANK switch |
| BCD Output | Open-collector / Switchover between 6-digit (positive/negative-true logic) and tolerance judgment output with parameter |
| Rating | Power supply voltage: 12 to 24 V DC Power consumption: 6 W or less (500 mA maximum) Ensure at least 1 A is available per unit |
| Temperature Range | Operating: 0 to 40°C (RH 20 to 80%, no condensation) Storage: –10 to 50°C (RH 20 to 80%, no condensation) |
| Applicable Input | Differential square-wave |
| Number of Gauge Inputs | 1 |
| Dimensions | 3.78 x 1.89 x 6.14" (96 × 48 × 156 mm) |
| Weight | 0.88 lbs (400 g) |
| Applicable Gauge Head | LGE, LGF, LGK, LGB, LGM, LG, LGH (Not compatible with LGH110, reference point or sine wave models) |
| Number of Gauge Inputs | 1 |
| Quantizing Error | ±1 count |
| Maximum Input Frequency | 1.25 MHz, response speed depends on gauge specification |
| Resolution | 0.01 mm (±9999.99 mm)/0.0005" (±99.9995")/0.001" (±999.999") 0.005mm (±9999.995mm)/0.00005" (±9.99995")/0.0001" (±99.999") 0.001mm (±999.999mm)/0.00005" (±9.99995")/0.0001"(±99.999") 0.0005mm (±99.9995mm)/0.000005" (±.999995")/0.00001" (±9.99999") 0.0001mm (±99.9999mm)/0.000005" (±.999995")/0.00001" (±9.99999") |
| Display | Sign plus 6 digits (Green LED) |
| Tolerance Judgment | Display: LED display (3 steps: Amber, green, red/5 steps: amber, amber flashing, green, red flashing, red) L1 to L5 (Open-collector/switchover between L1 to L5 and BCD output with parameter) |
| Control | Output: Normal operation signal (NOM): open-collector Input: Pre setting, display hold, peak value clear, tolerance judgment BANK switch |
| BCD Output | Open-collector / Switchover between 6-digit (positive/negative-true logic) and tolerance judgment output with parameter |
| Rating | Power supply voltage: 12 to 24 V DC Power consumption: 6 W or less (500 mA maximum) Ensure at least 1 A is available per unit |
| Temperature Range | Operating: 0 to 40°C (RH 20 to 80%, no condensation) Storage: –10 to 50°C (RH 20 to 80%, no condensation) |
| Applicable Input | Differential square-wave |
| Number of Gauge Inputs | 1 |
| Dimensions | 3.78 x 1.89 x 6.14" (96 × 48 × 156 mm) |
| Weight | 0.88 lbs (400 g) |