Megger MPAC-V Professional Acoustic Camera Verifier/Ultrasound Generator, 96 kHz

Model: MPAC-V | Order No: 1016-919

Megger MPAC-V Professional Acoustic Camera Verifier/Ultrasound Generator, 96 kHz

Model: MPAC-V | Order No: 1016-919

Compact and portable, this acoustic camera verifier is designed to verify the alignment of the acoustic cloud image, the accuracy of the SPL (Sound Pressure Level) measurement, and the frequency response of the MPAC acoustic cameras. In addition, it supports a maximum signal output sampling rate of 96 kHz 24-bit.
(This verifier/generator is not intended to be used in explosive atmospheres.)

Compact and portable, this acoustic camera verifier is designed to verify the alignment of the acoustic cloud image, the accuracy of the SPL (Sound Pressure Level) measurement, and the frequency response of the MPAC acoustic cameras. In addition, it supports a maximum signal output sampling rate of 96 kHz 24-bit.
(This verifier/generator is not intended to be used in explosive atmospheres.)

Your Price $2921.74 USD
Availability 2 to 3 Weeks
Quantity

Megger MPAC-V Offers

The Megger Professional Acoustic Camera Verifier, MPAC-V has button controls to power on/off the MPAC-V, play/ pause an audio file, increase/decrease the volume and switch between the .wav audio files, pre-loaded onto the included MicroSD/TF card.

Key is the inclusion of a Verification sound file that automatically runs through the pre-set frequency bands that mirror the bands selected by the MPAC cameras when running in verification mode, automating the verification process.

In addition, sound files to replicate common partial discharge, using either 50 Hz or 60 Hz as the fundamental, help prove the MPAC cameras detection processor.

The MPAC-V supports a maximum signal output sampling rate of 96 kHz 24 bit, with a rated frequency range from 20 kHz to 48 kHz.

The product features a lightweight, sturdy and durable all-aluminium alloy case and can be powered by either the supplied USB-C 5 V power adaptor or four AA batteries.

Features

  • 8 audio files including the camera verification file, preset mechanical frequency files, white noise and gas leak, as well as samples of Suspension, Corona and Surface Partial Discharge – all at both 50 and 60 Hz
  • Used to verify the operational status of the Megger MPACs (Megger Professional Acoustic imaging Cameras - MPAC128 and MPAC208)
  • A dual-port USB-C power adaptor and USB-C cable are supplied as standard
  • Designed to fit into the Megger MPAC cameras protective carry case

Applications

  • Sound pressure level verifier
  • Frequency response verification
  • Acoustic cloud image alignment verification
  • Multiple preloaded sound files to verify correct camera performance

Megger MPAC-V Specifications

Acoustic Specifications
Sampling Rate 96 kHz
Frequency Range 20 to 48 kHz
Operating Frequency 25 kHz ± 5 kHz
Supported File Type .wav
Power Supply
Port USB-C
Rated Voltage: 5 V (DC)
Current: 0.5 A
Battery Type AA (Alkaline or Ni-Cad batteries are recommended: 4 required)
General Specifications
Tripod Mounting Point ¼" thread
Screen LCD – 2.8"
Resolution 320 x 240
Environmental Conditions Operating: -4 to 140°F (-20 to 60°C), 10 to 95%
Storage: -4 to 158°F (-20 to 70°C), 10 to 95%
Certification CE-EMC, CE-RoHS
Storage Size Maximum 64 GB MicroSD card
Dimensions 6.81 x 3.15 x 1.38" (173 x 80 x 35 mm)
Weight 1.32 lbs (600 g)
Click here for complete specifications on the Megger MPAC-V

What's included with the Megger MPAC-V

  • Acoustic Camera Verifier

Megger MPAC-V Offers

The Megger Professional Acoustic Camera Verifier, MPAC-V has button controls to power on/off the MPAC-V, play/ pause an audio file, increase/decrease the volume and switch between the .wav audio files, pre-loaded onto the included MicroSD/TF card.

Key is the inclusion of a Verification sound file that automatically runs through the pre-set frequency bands that mirror the bands selected by the MPAC cameras when running in verification mode, automating the verification process.

In addition, sound files to replicate common partial discharge, using either 50 Hz or 60 Hz as the fundamental, help prove the MPAC cameras detection processor.

The MPAC-V supports a maximum signal output sampling rate of 96 kHz 24 bit, with a rated frequency range from 20 kHz to 48 kHz.

The product features a lightweight, sturdy and durable all-aluminium alloy case and can be powered by either the supplied USB-C 5 V power adaptor or four AA batteries.

Features

  • 8 audio files including the camera verification file, preset mechanical frequency files, white noise and gas leak, as well as samples of Suspension, Corona and Surface Partial Discharge – all at both 50 and 60 Hz
  • Used to verify the operational status of the Megger MPACs (Megger Professional Acoustic imaging Cameras - MPAC128 and MPAC208)
  • A dual-port USB-C power adaptor and USB-C cable are supplied as standard
  • Designed to fit into the Megger MPAC cameras protective carry case

Applications

  • Sound pressure level verifier
  • Frequency response verification
  • Acoustic cloud image alignment verification
  • Multiple preloaded sound files to verify correct camera performance

Megger MPAC-V Specifications

Acoustic Specifications
Sampling Rate 96 kHz
Frequency Range 20 to 48 kHz
Operating Frequency 25 kHz ± 5 kHz
Supported File Type .wav
Power Supply
Port USB-C
Rated Voltage: 5 V (DC)
Current: 0.5 A
Battery Type AA (Alkaline or Ni-Cad batteries are recommended: 4 required)
General Specifications
Tripod Mounting Point ¼" thread
Screen LCD – 2.8"
Resolution 320 x 240
Environmental Conditions Operating: -4 to 140°F (-20 to 60°C), 10 to 95%
Storage: -4 to 158°F (-20 to 70°C), 10 to 95%
Certification CE-EMC, CE-RoHS
Storage Size Maximum 64 GB MicroSD card
Dimensions 6.81 x 3.15 x 1.38" (173 x 80 x 35 mm)
Weight 1.32 lbs (600 g)
Click here for complete specifications on the Megger MPAC-V

What's included with the Megger MPAC-V

  • Acoustic Camera Verifier