The AVO215 True RMS Digital Multimeter offers a wide range of functions in a pocket-sized, yet rugged package. It meets CAT III 600 V AC/DC safety standards and features a built-in flashlight, making it ideal for wide range of applications.
The AVO215 True RMS Digital Multimeter offers a wide range of functions in a pocket-sized, yet rugged package. It meets CAT III 600 V AC/DC safety standards and features a built-in flashlight, making it ideal for wide range of applications.
The AVO215 includes such user-friendly features as auto and manual ranging, data hold, MAX/MIN recording, and a built-in flashlight, enhancing usability in diverse working conditions. It meets CAT III 600 V AC/DC safety standards and is designed to withstand drops up to 2 meters, ensuring reliability in harsh environments.
Features
Applications
| DC Voltage | |
| 400 mV | Resolution: 0.1 mV Accuracy: ±(1.0% reading + 5 digits) |
| 4 V | Resolution: 0.001 V Accuracy: ±(1.0% reading + 3 digits) |
| 40 V | Resolution: 0.01 V Accuracy: ±(1.0% reading + 3 digits) |
| 400 V | Resolution: 0.1 V Accuracy: ±(1.0% reading + 3 digits) |
| 600 V | Resolution: 1 V Accuracy: ±(1.0% reading + 3 digits) |
| AC Voltage | |
| 4 V | Resolution: 0.001 V Accuracy: ±(1.2% reading + 5 digits) |
| 40 V | Resolution: 0.01 V Accuracy: ±(1.2% reading + 5 digits) |
| 400 V | Resolution: 0.1 V Accuracy: ±(1.2% reading + 5 digits) |
| 600 V | Resolution: 1 V Accuracy: ±(1.2% reading + 5 digits) |
| Note | All AC voltage ranges are specified from 5 of range to 100% of range |
| DC Current | |
| 400 µA | Resolution: 0.1 µA Accuracy: ±(1.0% reading + 3 digits) |
| 4000 µA | Resolution: 1 µA Accuracy: ±(1.0% reading + 3 digits) |
| 40 mA | Resolution: 0.01 mA Accuracy: ±(1.2% reading + 3 digits) |
| 400 mA | Resolution: 0.1 mA Accuracy: ±(1.2% reading + 3 digits) |
| 4 A | Resolution: 0.001 A Accuracy: ±(1.2% reading + 3 digits) |
| 10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) (20 A: 30 seconds maximum with reduced accuracy) |
| Note | (20 A: 30 seconds maximum with reduced accuracy) |
| AC Current | |
| 400 µA | Resolution: 0.1 µA Accuracy: ±(1.2% reading + 3 digits) |
| 4000 µA | Resolution: 1 µA Accuracy: ±(1.2% reading + 3 digits) |
| 40 mA | Resolution: 0.01 mA Accuracy: ±(1.5% reading + 5 digits) |
| 400 mA | Resolution: 0.1 mA Accuracy: ±(1.5% reading + 5 digits) |
| 4 A | Resolution: 0.001 A Accuracy: ±(1.8% reading + 5 digits) |
| 10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) |
| Note | (20 A: 30 seconds maximum with reduced accuracy) |
| Resistance | |
| 400 Ω | Resolution: 0.1 Ω Accuracy: ±(1.5% reading + 5 digits) |
| 4 kΩ | Resolution: 0.001 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 40 kΩ | Resolution: 0.01 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 400 kΩ | Resolution: 0.1 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 4 MΩ | Resolution: 0.001 MΩ Accuracy: ±(2.5% reading + 20 digits) |
| 40 MΩ | Resolution: 0.01 MΩ Accuracy: ±(2.5% reading + 20 digits) |
| Capacitance | |
| 40 nF | Resolution: 0.01 nF Accuracy: ±(4.5% reading + 10 digits) |
| 400 nF | Resolution: 0.1 nF Accuracy: ±(3.0% reading + 5 digits) |
| 4 µF | Resolution: 0.001 µF Accuracy: ±(3.0% reading + 5 digits) |
| 40 µF | Resolution: 0.01 µF Accuracy: ±(5% reading + 5 digits) |
| 400 µF | Resolution: 0.1 µF Accuracy: ±(5% reading + 5 digits) |
| 4000 µF | Resolution: 1 µF Accuracy: ±(5% reading + 5 digits) |
| Frequency | |
| 10 Hz to 10 kHz | Resolution: 0.01 Hz Accuracy: ±(1.2% reading) Sensitivity: 15 V rms |
| Duty Cycle | |
| 0.1 to 99.9% | Resolution: 0.1 % Accuracy: ±(1.2% reading + 2 digits) Note: Pulse width: 100 µs to 100 ms Frequency: 5 Hz to 150 kHz |
| General Specifications | |
| Diode Test | Test current of 1.5 mA max, open circuit voltage 3 V DC typical |
| Continuity Check | Audible signal if resistance <50 Ω (approx.), test current <0.35 mA |
| Input Impedance | >10 MΩ (V DC / V AC) |
| AC Response | True RMS |
| ACV Bandwidth | 50/60 Hz (all waveforms) 45 to 1000 Hz (sine wave) |
| Crest Factor | ≤3 at full scale up to 300 V, decreasing linearly to ≤1.5 at 600 V |
| Display | 4000 counts / positive display |
| Overrange Indication | OL' is displayed |
| Polarity | Automatic, minus symbol for negative values |
| Measurement Rate | 3 times per second |
| Fuses | mA / µA ranges: 0.5 A 600 V ceramic quick blow A range: 10 A 600 V ceramic quick blow |
| Environmental Conditions | Operating temperature: 41 to 104 °F (5 to 40 °C) Storage temperature: -4 to 140 °F (-20 to 60 °C) Operating humidity: Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40 °C) Storage humidity: <80% Operating altitude: ≤7000' (2000 m) Drop test: 6.5' (2 m) |
| Safety Rating | IEC61010, CAT III 600 V |
| Battery | 2 x 1.5 V AAA |
| Dimensions | 182 x 82 x 59 mm |
| Weight | 0.753 lbs (342 g) |
| DC Voltage | |
| 400 mV | Resolution: 0.1 mV Accuracy: ±(1.0% reading + 5 digits) |
| 4 V | Resolution: 0.001 V Accuracy: ±(1.0% reading + 3 digits) |
| 40 V | Resolution: 0.01 V Accuracy: ±(1.0% reading + 3 digits) |
| 400 V | Resolution: 0.1 V Accuracy: ±(1.0% reading + 3 digits) |
| 600 V | Resolution: 1 V Accuracy: ±(1.0% reading + 3 digits) |
| AC Voltage | |
| 4 V | Resolution: 0.001 V Accuracy: ±(1.2% reading + 5 digits) |
| 40 V | Resolution: 0.01 V Accuracy: ±(1.2% reading + 5 digits) |
| 400 V | Resolution: 0.1 V Accuracy: ±(1.2% reading + 5 digits) |
| 600 V | Resolution: 1 V Accuracy: ±(1.2% reading + 5 digits) |
| Note | All AC voltage ranges are specified from 5 of range to 100% of range |
| DC Current | |
| 400 µA | Resolution: 0.1 µA Accuracy: ±(1.0% reading + 3 digits) |
| 4000 µA | Resolution: 1 µA Accuracy: ±(1.0% reading + 3 digits) |
| 40 mA | Resolution: 0.01 mA Accuracy: ±(1.2% reading + 3 digits) |
| 400 mA | Resolution: 0.1 mA Accuracy: ±(1.2% reading + 3 digits) |
| 4 A | Resolution: 0.001 A Accuracy: ±(1.2% reading + 3 digits) |
| 10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) (20 A: 30 seconds maximum with reduced accuracy) |
| Note | (20 A: 30 seconds maximum with reduced accuracy) |
| AC Current | |
| 400 µA | Resolution: 0.1 µA Accuracy: ±(1.2% reading + 3 digits) |
| 4000 µA | Resolution: 1 µA Accuracy: ±(1.2% reading + 3 digits) |
| 40 mA | Resolution: 0.01 mA Accuracy: ±(1.5% reading + 5 digits) |
| 400 mA | Resolution: 0.1 mA Accuracy: ±(1.5% reading + 5 digits) |
| 4 A | Resolution: 0.001 A Accuracy: ±(1.8% reading + 5 digits) |
| 10 A | Resolution: 0.01 A Accuracy: ±(1.8% reading + 5 digits) |
| Note | (20 A: 30 seconds maximum with reduced accuracy) |
| Resistance | |
| 400 Ω | Resolution: 0.1 Ω Accuracy: ±(1.5% reading + 5 digits) |
| 4 kΩ | Resolution: 0.001 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 40 kΩ | Resolution: 0.01 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 400 kΩ | Resolution: 0.1 kΩ Accuracy: ±(1.5% reading + 5 digits) |
| 4 MΩ | Resolution: 0.001 MΩ Accuracy: ±(2.5% reading + 20 digits) |
| 40 MΩ | Resolution: 0.01 MΩ Accuracy: ±(2.5% reading + 20 digits) |
| Capacitance | |
| 40 nF | Resolution: 0.01 nF Accuracy: ±(4.5% reading + 10 digits) |
| 400 nF | Resolution: 0.1 nF Accuracy: ±(3.0% reading + 5 digits) |
| 4 µF | Resolution: 0.001 µF Accuracy: ±(3.0% reading + 5 digits) |
| 40 µF | Resolution: 0.01 µF Accuracy: ±(5% reading + 5 digits) |
| 400 µF | Resolution: 0.1 µF Accuracy: ±(5% reading + 5 digits) |
| 4000 µF | Resolution: 1 µF Accuracy: ±(5% reading + 5 digits) |
| Frequency | |
| 10 Hz to 10 kHz | Resolution: 0.01 Hz Accuracy: ±(1.2% reading) Sensitivity: 15 V rms |
| Duty Cycle | |
| 0.1 to 99.9% | Resolution: 0.1 % Accuracy: ±(1.2% reading + 2 digits) Note: Pulse width: 100 µs to 100 ms Frequency: 5 Hz to 150 kHz |
| General Specifications | |
| Diode Test | Test current of 1.5 mA max, open circuit voltage 3 V DC typical |
| Continuity Check | Audible signal if resistance <50 Ω (approx.), test current <0.35 mA |
| Input Impedance | >10 MΩ (V DC / V AC) |
| AC Response | True RMS |
| ACV Bandwidth | 50/60 Hz (all waveforms) 45 to 1000 Hz (sine wave) |
| Crest Factor | ≤3 at full scale up to 300 V, decreasing linearly to ≤1.5 at 600 V |
| Display | 4000 counts / positive display |
| Overrange Indication | OL' is displayed |
| Polarity | Automatic, minus symbol for negative values |
| Measurement Rate | 3 times per second |
| Fuses | mA / µA ranges: 0.5 A 600 V ceramic quick blow A range: 10 A 600 V ceramic quick blow |
| Environmental Conditions | Operating temperature: 41 to 104 °F (5 to 40 °C) Storage temperature: -4 to 140 °F (-20 to 60 °C) Operating humidity: Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40 °C) Storage humidity: <80% Operating altitude: ≤7000' (2000 m) Drop test: 6.5' (2 m) |
| Safety Rating | IEC61010, CAT III 600 V |
| Battery | 2 x 1.5 V AAA |
| Dimensions | 182 x 82 x 59 mm |
| Weight | 0.753 lbs (342 g) |